CEA key terms
CEA · Get comfortable with the vocabulary.
- Energy audit scope
- Related: Audit level (ASHRAE Level 1/2/3), Baseline year
The documented boundary defining which facilities, systems, fuels, and time periods an audit covers, including what is excluded and why, so findings and savings estimates are interpreted correctly.
- Audit level (ASHRAE Level 1/2/3)
- Related: Energy audit scope, Simple payback
A tiered classification of audit depth: Level 1 is a walk-through screening with rough savings, Level 2 adds detailed system analysis and costed measures, Level 3 adds rigorous engineering and financial modeling for capital decisions.
- Baseline year
- Related: Energy use intensity (EUI), Weather normalization
The reference period of historical consumption and cost against which future performance and savings are measured, ideally chosen as a typical year with reliable, complete utility data.
- Energy use intensity (EUI)
- Related: Baseline year, Energy balance
Annual energy consumption divided by a size or activity metric, such as kWh per square metre or gigajoules per tonne of product, allowing comparison of buildings or plants of different sizes.
- Load profile
- Related: Load factor, Baseload
The pattern of energy demand over time, typically shown as hourly, daily, or seasonal demand curves, revealing peaks, part-load behavior, and scheduling opportunities that drive equipment selection and control strategies.
- Load factor
- Related: Load profile, Demand charge
Average load divided by peak load over a period, expressed as a fraction or percentage; a low value indicates demand peaks that may justify load shifting, storage, or right-sizing rather than energy reduction alone.
- Baseload
- Related: Load profile, Energy balance
The minimum continuous energy demand that persists during unoccupied or non-production hours, often caused by standby equipment, controls left on, or leaks, and a frequent target for low-cost savings.
- Energy balance
- Related: Baseload, Submetering
A reconciliation of energy inputs against end uses and losses within a defined boundary, used to identify unaccounted consumption and prioritize systems for measurement and improvement.
- Submetering
- Related: Measurement and verification (M&V), Energy balance
Installing meters below the main utility service to measure consumption of individual systems, tenants, or processes, enabling allocation of costs and verification of savings from specific measures.
- Measurement and verification (M&V)
- Related: Submetering, Weather normalization
A documented process using metered data and agreed methods to determine actual savings achieved by an energy conservation measure, accounting for changes in weather, occupancy, and production.
- Weather normalization
- Related: Degree day, Baseline year
Statistical adjustment of energy consumption to remove the effect of outdoor temperature variation, typically using heating and cooling degree days, so that different periods can be compared fairly.
- Degree day
- Related: Weather normalization, Load profile
A measure of heating or cooling demand obtained by summing the daily differences between a reference base temperature and the mean outdoor temperature, used to model weather-dependent energy use.
- Simple payback
- Related: Life-cycle cost analysis, Net present value (NPV)
The initial capital cost of a measure divided by its annual net savings, giving the number of years to recover the investment; easy to communicate but ignores savings after payback and time value of money.
- Life-cycle cost analysis
- Related: Net present value (NPV), Discount rate
A method comparing options by summing all costs over the study period, including capital, energy, maintenance, and replacement, discounted to present value, rather than judging on first cost alone.
- Net present value (NPV)
- Related: Discount rate, Internal rate of return (IRR)
The sum of future cash flows discounted to today's value using a chosen discount rate; a positive NPV indicates the measure returns more than the required rate of return.
- Internal rate of return (IRR)
- Related: Net present value (NPV), Discount rate
The discount rate at which a measure's net present value equals zero, expressing project profitability as a percentage that can be compared with a company's hurdle rate.
- Discount rate
- Related: Net present value (NPV), Life-cycle cost analysis
The rate used to convert future costs and savings into present value, reflecting the organization's cost of capital or required return and the risk of the investment.
- Luminous efficacy
- Related: Lighting power density (LPD), Lumen maintenance
The ratio of light output to electrical power input, expressed in lumens per watt, used to compare lamp and luminaire technologies and to estimate lighting energy savings.
- Lighting power density (LPD)
- Related: Luminous efficacy, Daylight harvesting
Installed lighting wattage divided by floor area, typically in watts per square metre, used to benchmark a space against code limits and to size lighting retrofit savings.
- Daylight harvesting
- Related: Lighting power density (LPD), Occupancy sensor
Automatic dimming or switching of electric lighting in response to available daylight measured by photosensors, reducing lighting energy while maintaining target illuminance in the space.
- Occupancy sensor
- Related: Daylight harvesting, Setback
A device that detects presence, using passive infrared, ultrasonic, or both, to switch or dim lighting and sometimes HVAC in unoccupied spaces, capturing savings from reduced run hours.
- Coefficient of performance (COP)
- Related: Part-load value (PLV), Economizer
The ratio of useful heating or cooling output to energy input at a given operating condition; higher values mean greater efficiency, and the value varies with source and load temperatures.
- Part-load value (PLV)
- Related: Coefficient of performance (COP), Variable speed drive (VSD)
An efficiency rating for chillers that weights performance at several partial loads, better representing real operation than a single full-load rating because chillers rarely run fully loaded.
- Economizer
- Related: Setback, Ventilation rate
A control strategy or damper arrangement that uses cool outdoor air instead of mechanical cooling when conditions permit, reducing compressor energy during mild weather and shoulder seasons.
- Setback
- Related: Occupancy sensor, Economizer
Scheduled relaxation of space temperature or ventilation during unoccupied hours so equipment runs less, with savings dependent on building mass, recovery time, and acceptable restart conditions.
- Ventilation rate
- Related: Economizer, Heat recovery ventilator (HRV)
The volume of outdoor air supplied to a space per unit time or per occupant, set for indoor air quality; reducing excess ventilation saves conditioning energy but must respect minimum requirements.
- Domestic hot water (DHW) load
- Related: Hot water recirculation loop, Tank insulation
The energy required to raise water from supply to delivery temperature plus distribution and storage losses, driven by draw volume, setpoint, and pipe insulation condition.
- Hot water recirculation loop
- Related: Domestic hot water (DHW) load, Tank insulation
A pumped piping circuit that keeps hot water available at fixtures; necessary for convenience but a source of standing losses, so pump control and pipe insulation strongly affect DHW energy use.
- Tank insulation
- Related: Domestic hot water (DHW) load, Hot water recirculation loop
Thermal wrapping on storage tanks and adjacent piping that reduces standby heat loss, an inexpensive retrofit with predictable savings where tank surfaces are warm to the touch.
- Variable speed drive (VSD)
- Related: Affinity laws, Motor load factor
An electronic controller that adjusts motor speed to match load instead of throttling or cycling, yielding large savings for fans and pumps because power varies roughly with the cube of speed.
- Affinity laws
- Related: Variable speed drive (VSD), System curve
Relationships for centrifugal fans and pumps stating that flow varies with speed, pressure with speed squared, and power with speed cubed, explaining why modest speed reductions save substantial energy.
- Motor load factor
- Related: Variable speed drive (VSD), Power factor
The ratio of actual output power to nameplate rated power; oversized motors running lightly loaded operate inefficiently, so measuring load guides right-sizing and replacement decisions.
- Compressed air specific power
- Related: Compressed air leak survey, Pressure dew point
The electrical power required to produce a unit of compressed air flow, such as kW per cubic metre per minute, used to benchmark compressors and detect degradation or poor control.
- Compressed air leak survey
- Related: Compressed air specific power, Pressure dew point
A systematic inspection, often with ultrasonic detection, that locates leaks in piping, fittings, and tools; leaks typically waste a large share of compressor output and repairs are usually low cost.
- Pressure dew point
- Related: Compressed air specific power, Compressed air leak survey
The temperature at which moisture condenses from compressed air at system pressure; specifying it correctly for dryers prevents pipe corrosion and product contamination without over-drying and wasting energy.
- Thermal bridging
- Related: R-value, Air leakage
A path of high-conductivity material through insulation, such as steel studs or slab edges, that bypasses the intended thermal resistance and increases heat flow through the envelope.
- Air leakage
- Related: Thermal bridging, R-value
Unintentional movement of air through gaps, joints, and penetrations in the envelope, carrying both sensible and latent heat and often a major cause of excess heating and cooling load.
- R-value
- Related: Thermal bridging, Air leakage
A measure of thermal resistance of a material or assembly, where higher values mean better insulation; assemblies must be rated for their weakest path and installed condition.
- Building automation system (BAS)
- Related: Trend log, Control sequence
A networked control system that monitors and commands HVAC, lighting, and other building equipment through sensors, controllers, and a central interface, generating trend data useful for audits.
- Trend log
- Related: Building automation system (BAS), Control sequence
A time-stamped record of a sensor or setpoint value collected by a control system, used to diagnose scheduling faults, simultaneous heating and cooling, and equipment short cycling.
- Control sequence
- Related: Trend log, Setback
The documented logic specifying how equipment responds to conditions, including setpoints, staging, and reset schedules; mismatches between intended and actual sequences commonly waste energy.
- Combined heat and power (CHP)
- Related: Demand charge, Battery energy storage
On-site generation of electricity and useful heat from one fuel source, achieving higher overall efficiency than separate generation when thermal output can be used year-round.
- Battery energy storage
- Related: Demand charge, Combined heat and power (CHP)
An electrochemical system that stores electricity for later use, enabling peak shaving, demand charge reduction, and backup, with economics driven by tariff structure and cycle life.
- Demand charge
- Related: Load profile, Battery energy storage
A utility billing component based on the highest average power drawn during a billing period, giving strong incentive to shave peaks through scheduling, storage, or load shifting.
- Fleet energy management
- Related: Telematics, Route optimization
Strategies to reduce transport energy across vehicles, including route optimization, driver behavior, idling reduction, and right-sizing, often supported by telematics data collection.
- Telematics
- Related: Fleet energy management, Route optimization
On-vehicle sensors and communications that record fuel use, idling, speed, and location, providing the data needed to quantify transport energy savings and verify driver or routing changes.
- Route optimization
- Related: Telematics, Fleet energy management
Planning deliveries or service trips to minimize distance, time, and stops, reducing fuel consumption without changing vehicles; savings depend on current routing practice and load constraints.