NY Well Driller study materials
NY Well Driller study resources

Flowing Artesian Well in Glacial Sand and Gravel

NY Well Driller · Put your knowledge to work in context.

All case studies

Flowing Artesian Well in Glacial Sand and Gravel

A new 6-inch PVC well is planned for a lakeside cottage in Cayuga County. Test boring shows 4 feet of topsoil, 28 feet of fine-to-medium sand, then 30 feet of gravel, then shale. A piezometer in the gravel reads 3 feet above ground surface when the borehole is open. The driller proposes an 8-inch borehole to 65 feet, 6-inch Schedule 40 PVC casing, a 15-foot factory slotted screen, and a bentonite seal above the screen. The owner wants the well to flow by gravity to a cistern and asks whether the flow can be used to avoid a pump. The site is 100 feet from the lake, and the local health department requires a sanitary seal. The driller has a bag of 3/8-inch bentonite chips and neat cement grout on site.

1. Select the screen, filter pack, and annular seal. Explain the reasoning and identify any problem with the proposed materials.

Read the worked answer

Start with sieve analysis of the sand and gravel. Because the producing zone includes fine-to-medium sand, a factory slotted screen alone may clog or pass sand. Use a clean, washed filter pack selected so the formation bridges on the pack, and choose the screen slot to retain the pack, typically a slot that holds about 90% of the pack. The 3/8-inch bentonite chips are too coarse for a thin annular seal above a screen; they can bridge and leave voids. Use fine bentonite pellets or a bentonite/cement grout, placed carefully, with a seal of adequate thickness. Above the seal, grout the annulus to surface to meet the sanitary-seal requirement. For the artesian head, the casing must extend above grade, be sealed, and have a flow-control valve. Do not attempt to grout against uncontrolled flow; control the head with a packer or valve first, then pressure-grout.

2. Can the 3-foot artesian head replace a pump to the cistern? What design and operating problems must be addressed?

Read the worked answer

A 3-foot head is only about 1.3 psi. It can move water to a cistern at the same grade through a large, properly sloped pipe, but it will not provide useful household pressure and may be unreliable in winter. More importantly, an open flowing well is a contamination and freeze risk. The design should include a sealed wellhead, a sample tap, a flow-control valve, a meter, and an insulated or pitless line to the cistern. Provide a safe overflow and an air gap so the cistern cannot back-siphon into the well. Keep a pump and pressure tank for reliability and pressure. Test the water for coliform, iron, manganese, and other site-specific constituents before use, and inspect the grout seal because a flowing annulus can wash out grout during construction.