CSLB Land Development Engineering · Put your knowledge to work in context.

All case studies

Water Main Pressure at the Top of a Loop

A 2,000-ft, 12-inch ductile iron water main loops a new hillside neighborhood to an existing 12-inch main at the bottom of the hill. The existing main has a pressure of 72 psi at the connection under peak-hour demand, and the static pressure at the connection is 95 psi. The highest service connection is 140 ft above the connection elevation. The fire flow requirement at the top of the loop is 1,000 gpm at 20 psi residual. The engineer's model shows 68 psi at the top connection under peak-hour demand and 24 psi residual at 1,000 gpm. A PRV is proposed at the bottom connection set to 80 psi.

1. Evaluate the pressure results against typical criteria and identify any conflict with the proposed PRV setting.

Read the worked answer

Convert elevation to pressure: 140 ft x 0.433 psi/ft = 60.6 psi of static loss from the connection to the top. Static pressure at the top is therefore about 95 - 60.6 = 34.4 psi, and peak-hour pressure is about 72 - 60.6 = 11.4 psi before friction losses. The model's 68 psi at the top under peak-hour demand is inconsistent with that arithmetic unless the model is reporting pressure at a different node or ignoring the elevation difference - this must be reconciled, because if the true peak-hour pressure at the top is near 11 psi, it fails the usual 20-psi minimum. The fire-flow result of 24 psi residual at 1,000 gpm is close to but above the 20-psi criterion, so fire flow is marginally acceptable. The PRV conflict: setting the PRV to 80 psi at the bottom reduces the downstream static head, which further lowers pressure at the top. The PRV is intended to protect the lower zone from high static pressure, but it must be set high enough that the top of the loop still meets minimum pressure under peak and fire conditions. The engineer must verify the model's elevation handling, confirm the top-of-loop pressures satisfy both peak-hour (typically 20 psi minimum) and fire-flow criteria with the PRV in service, and consider a booster or a higher PRV setting if the top cannot be served.

2. If the top-of-loop pressure cannot be met, what are the feasible engineering responses, and what are their tradeoffs?

Read the worked answer

Options, roughly in order of preference: (1) Raise the PRV setting or eliminate it if the lower zone can tolerate the higher static pressure - cheapest, but may violate the lower zone's pressure limits and pipe rating. (2) Increase main size along the loop to reduce friction loss - reduces head loss but does little for the elevation-driven static loss, so it only helps the fire-flow residual, not the static deficit. (3) Add a booster pump station at the top of the loop - directly solves low pressure but adds capital, energy, and maintenance, and requires standby power and storage for reliability. (4) Add an elevated storage tank or hydropneumatic storage at the top to supply peak and fire demand - improves reliability and fire flow but is expensive and needs a site. (5) Reduce the elevation of the highest service connection or serve it from a separate pressure zone - a land-planning solution that may be the most reliable. (6) Reconfigure the loop into two pressure zones with a PRV between them. The tradeoff is always capital and operating cost versus reliability; the engineer should present the options with lifecycle costs and confirm the selected approach meets the fire-flow and minimum-pressure criteria under worst-case demand.