OR HVAC Contractor study materials
OR HVAC Contractor study resources

OR HVAC Contractor key terms

OR HVAC Contractor · Get comfortable with the vocabulary.

Oregon Construction Contractors Board (CCB) license

A credential issued by the state board that allows a business to offer or perform construction work, including HVAC installation, for compensation in Oregon. It requires a bond, insurance, and a qualifying individual who passes the required exam.

Related: Qualifying individual, Contractor bond, Notice of procedure
Qualifying individual

The person named on a contractor's license who has met the training and exam requirements and is responsible for the contractor's compliance with Oregon law. The license depends on this person's continued eligibility and good standing.

Related: Oregon Construction Contractors Board (CCB) license
Contractor bond

A surety bond a licensed Oregon contractor must keep in force to protect customers who suffer damages from the contractor's improper work or abandonment. A claim against the bond is filed through the state contractors board.

Related: Oregon Construction Contractors Board (CCB) license, Notice of procedure
Notice of procedure

A written statement Oregon contractors must give residential customers, describing the right to file a complaint with the contractors board and to pursue the contractor's bond. It is typically required in the contract or as an attachment.

Related: Contractor bond, Oregon Construction Contractors Board (CCB) license
Written contract requirement

Oregon rules require a written contract for residential work above a set dollar threshold, signed by both parties and stating the scope, price, and payment terms. Change orders must also be documented in writing.

Related: Notice of procedure, Lien
Construction lien

A legal claim recorded against real property by a contractor or supplier who was not paid for labor or materials that improved the property. Strict notice and deadline rules apply, and the lien can lead to foreclosure.

Related: Notice of right to lien, Preliminary notice
Notice of right to lien

A written warning an Oregon contractor must give an owner at or before signing a contract, stating that unpaid contractors and suppliers may record a lien against the property. It protects the owner from surprise liens.

Related: Construction lien, Preliminary notice
Preliminary notice

A notice a material supplier or subcontractor may give the owner early in a project to preserve lien rights even without a direct contract with the owner. Timing and delivery methods are set by statute.

Related: Construction lien, Notice of right to lien
Retainage

A percentage of each progress payment an owner or general contractor withholds until the work is substantially complete. It provides leverage to finish punch-list items and resolve defects before final payment.

Related: Substantial completion, Punch list
Substantial completion

The stage when the work is sufficiently complete for the owner to use it for its intended purpose, even though minor items remain. It starts warranty periods and affects retainage and lien deadlines.

Related: Retainage, Punch list
Punch list

A written list of incomplete or defective items identified during a walkthrough near the end of a project. Completing the list is usually a condition of final payment and release of retainage.

Related: Retainage, Substantial completion
Oregon Mechanical Board

The state board that licenses mechanical contractors and certifies HVAC and refrigeration technicians, sets continuing education rules, and administers discipline for code violations. It works alongside the building codes division.

Related: Limited maintenance electrician license, Oregon Structural Specialty Code
Oregon Structural Specialty Code

The adopted statewide building code, based on the International Building Code with Oregon amendments, that governs structural, mechanical, and related construction requirements. Local governments enforce it with limited amendment authority.

Related: Permit, Inspection, Oregon Mechanical Board
Permit

Written authorization from a building department to install, alter, or replace regulated equipment. Work done without a permit can be ordered removed or exposed, and the contractor may face fines and license discipline.

Related: Inspection, Final inspection
Inspection

A building official's on-site review of permitted work at defined stages to confirm code compliance. The installer must request it, and work must be accessible for review before it is concealed.

Related: Permit, Final inspection
Final inspection

The last inspection that confirms all permitted work is complete and code compliant, allowing the system to be placed in service and the permit to be closed. It typically requires prior rough-in approvals.

Related: Inspection, Permit
Clearance to combustibles

The minimum distance required between heat-producing equipment, vent connectors, or flues and materials that can burn. Listed equipment labels state these distances, and reducing them without an approved method creates a fire hazard.

Related: Type B vent, Vent connector
Type B vent

A listed double-wall metal vent for venting listed gas appliances with draft hoods. Its design maintains an insulating air space, allowing reduced clearance to combustible materials compared with single-wall pipe.

Related: Vent connector, Clearance to combustibles
Vent connector

The pipe that carries flue gases from an appliance's draft hood or flue collar to the chimney or vent. Its size, slope, length, and rise are limited by code to ensure reliable draft.

Related: Type B vent, Draft hood, Clearance to combustibles
Draft hood

A device on a gas appliance that mixes flue gases with room air and breaks excessive draft, stabilizing the pressure at the appliance outlet. It also prevents downdrafts from blowing out the pilot or burner flame.

Related: Vent connector, Backdrafting
Backdrafting

A condition where combustion products spill from an appliance into the living space instead of rising up the vent, often because of depressurization, blockage, or a cold flue. It is a serious carbon monoxide hazard.

Related: Draft hood, Carbon monoxide, Combustion air
Combustion air

The air an appliance needs to burn fuel safely and to dilute flue gases. Codes specify how much must be supplied from indoors, outdoors, or a combination, and undersized supply causes incomplete combustion.

Related: Backdrafting, Carbon monoxide
Carbon monoxide

A colorless, odorless gas produced by incomplete combustion that binds to hemoglobin and can be fatal at low concentrations. HVAC work must prevent its generation and ensure it is vented outdoors.

Related: Backdrafting, Combustion air
Manual J load calculation

A room-by-room method for estimating heating and cooling loads from building envelope, orientation, and climate data. Sizing equipment from it prevents short cycling and poor humidity control.

Related: Manual D duct design, Manual S equipment selection, Sensible heat ratio
Manual D duct design

A method for sizing ducts and selecting fittings so that available static pressure matches the pressure drop through the distribution system. It uses room airflows from the load calculation.

Related: Manual J load calculation, External static pressure
Manual S equipment selection

A procedure for choosing equipment whose capacity matches the calculated load at the actual design conditions, including airflow and indoor wet-bulb. Oversizing is a common cause of comfort complaints.

Related: Manual J load calculation, Sensible heat ratio
Sensible heat ratio

The fraction of total cooling capacity that removes sensible heat, with the remainder removing latent heat. A high ratio means less moisture removal, so it helps diagnose humidity problems in a building.

Related: Manual J load calculation, Manual S equipment selection
External static pressure

The resistance to airflow measured at the supply and return plenums of an air handler, expressed in inches of water column. It indicates whether the duct system, filter, and coil are within the blower's rated capacity.

Related: Manual D duct design, Airflow
Airflow

The volume of air moving through a system per unit time, commonly expressed in cubic feet per minute. Correct airflow is required for capacity, temperature rise, and safe heat exchanger operation.

Related: External static pressure, Temperature rise
Temperature rise

The difference between supply and return air temperatures across a furnace or heat pump, checked against the manufacturer's rating plate range. An out-of-range rise signals airflow, fuel, or blower problems.

Related: Airflow, External static pressure
Superheat

The number of degrees a refrigerant vapor is above its saturation temperature at a given pressure. It is used to verify the expansion device setting and to confirm the evaporator is properly fed.

Related: Subcooling, TXV, Saturation temperature
Subcooling

The number of degrees a liquid refrigerant is below its saturation temperature at a given pressure. Measuring it helps confirm the condenser charge and the amount of liquid seal at the expansion device.

Related: Superheat, TXV
TXV

A thermostatic expansion valve that meters refrigerant into the evaporator while holding a target superheat. It responds to evaporator outlet temperature and pressure and is common in packaged and split systems.

Related: Superheat, Subcooling
Saturation temperature

The temperature at which a refrigerant changes phase at a given pressure. Comparing it with measured line temperatures is the basis for superheat and subcooling readings.

Related: Superheat, Subcooling, Refrigerant recovery
Refrigerant recovery

The process of removing refrigerant from a system into a recovery cylinder rather than venting it to the atmosphere. Federal rules prohibit knowing venting and require certified technicians and approved equipment.

Related: Section 608 certification, Saturation temperature
Section 608 certification

The federal technician credential required to buy or handle regulated refrigerants and to service appliances containing them. It is issued after passing an EPA-approved exam covering environmental and safety rules.

Related: Refrigerant recovery
Ground fault circuit interrupter

A device that trips when current leaks from the circuit to ground, protecting people from shock. The electrical code requires it for receptacles serving equipment in certain wet or outdoor locations.

Related: Disconnect, Overcurrent protection
Overcurrent protection

A fuse or circuit breaker that opens a circuit when current exceeds its rating, preventing conductor and equipment damage. HVAC equipment must be protected at or below the maximum rating on its nameplate.

Related: Disconnect, Ground fault circuit interrupter
Disconnect

A switch or breaker installed near equipment that removes all power for servicing. It must be within sight of the equipment and rated for the load, and its location must be clear to service personnel.

Related: Overcurrent protection, Lockout/tagout
Thermostat

A control that senses space temperature and signals heating or cooling equipment to run. Modern programmable and communicating models add scheduling, humidity control, and fault reporting functions.

Related: Control transformer, Sequence of operation
Control transformer

A small transformer that steps line voltage down to low voltage for thermostats, relays, and control boards. A shorted control circuit can overload and burn it out, causing a no-cooling call.

Related: Thermostat, Sequence of operation
Sequence of operation

The ordered steps a system follows from a call for heat or cool through startup, normal running, and shutdown. Troubleshooters compare the observed sequence with the manufacturer's documented sequence to locate faults.

Related: Thermostat, Control transformer
Gas piping pressure test

A required test of new or altered fuel gas piping using air or inert gas at a specified pressure for a set duration, with the system capped and isolated. Leaks are found with a bubble solution, never a flame.

Related: Sediment trap, Gas leak detection
Sediment trap

A short downward leg of pipe installed before a gas appliance's controls to catch dirt, scale, and condensate. It protects the gas valve and orifices from debris carried in the supply line.

Related: Gas piping pressure test, Drip leg
Drip leg

Another name for the sediment trap installed at the appliance connection, typically a tee with a capped nipple below the gas valve. It must be installed so debris settles out of the gas stream.

Related: Sediment trap
Gas leak detection

The practice of locating fuel gas leaks with an approved electronic detector or soap bubble solution applied to joints. Open flames are prohibited, and leaks must be repaired before the system is placed in service.

Related: Gas piping pressure test
Lockout/tagout

A procedure for de-energizing equipment, applying a personal lock and tag, and verifying zero energy before service. It prevents unexpected startup or release of stored energy such as refrigerant or gas pressure.

Related: Disconnect, Personal protective equipment
Personal protective equipment

Gear such as gloves, safety glasses, and respirators worn to reduce injury risk on the job. HVAC work may require it for refrigerant contact, brazing, sharp edges, and electrical hazards.

Related: Lockout/tagout, Refrigerant recovery
Micron gauge

An instrument that measures very low absolute pressure in microns to confirm a system has been evacuated of air and moisture before charging. A standing decay test shows whether the vacuum holds.

Related: Refrigerant recovery, Saturation temperature
Manifold gauge set

A tool with compound and high-pressure gauges plus hoses and valves used to read system pressures and to connect a recovery or vacuum pump. Proper purging prevents cross-contamination of refrigerants.

Related: Micron gauge, Refrigerant recovery