- General Duty Clause
- OSH Act Section 5(a)(1): each employer must furnish a workplace free from recognized hazards that are causing or likely to cause death or serious physical harm.
- OSHA inspection priority order
- In order: imminent danger, fatality or catastrophe involving three or more hospitalizations, valid employee complaint or referral, programmed inspection, and follow-up inspection.
- Section 11(c) retaliation complaint
- An employee who alleges retaliation for exercising rights under the OSH Act must file a complaint with OSHA within 30 days of the adverse action.
- State plan effectiveness requirement
- A state occupational safety and health plan must be at least as effective as the federal program, and federal OSHA approves and continuously monitors it.
- OSHA Form 300
- The Log of Work-Related Injuries and Illnesses. Each recordable case must be entered within seven calendar days after the employer learns of it.
- Form 300A posting window
- The annual summary of work-related injuries and illnesses must be certified by an executive and posted from February 1 through April 30 of the following year.
- 8-hour and 24-hour reporting
- Employers must report a work-related fatality to OSHA within 8 hours and an in-patient hospitalization, amputation, or loss of an eye within 24 hours.
- Recordkeeping retention period
- Retain the OSHA 300 Log, 301 Incident Reports, and 300A summaries for five years following the end of the calendar year they cover.
- General industry fall protection trigger
- Under 29 CFR 1910.28, employers must provide fall protection when employees are exposed to falls of four feet or more to a lower level.
- Guardrail dimension requirements
- The top rail must be 42 inches plus or minus 3 inches above the walking surface, with a midrail at about 21 inches and a toe board at least 3.5 inches high.
- Portable ladder 4-to-1 rule
- A non-self-supporting ladder is set one foot out from the wall for every four feet of working length and must extend three feet above the landing.
- Fixed ladder 24-foot threshold
- Fixed ladders 24 feet or longer require a ladder safety system or personal fall arrest system; new cages are prohibited and existing cages must be replaced by November 18, 2036.
- Personal fall arrest anchor strength
- Anchorage must support 5,000 pounds per attached employee, or be designed by a qualified person with a safety factor of at least two.
- De-energizing before electrical work
- Under 1910.333, live parts must be de-energized before work unless infeasible, then locked out and tested to verify the absence of voltage.
- Electrical working clearance
- For equipment rated 600 volts or less, a clear working space at least 30 inches wide, 36 inches deep, and 6.5 feet high is required.
- Flexible cord prohibition
- Flexible cords and cables may not be used as a substitute for the fixed wiring of a structure, nor run through walls, ceilings, or floors.
- Qualified electrical person
- A person trained and knowledgeable in the construction and operation of electrical equipment and the hazards involved, permitted to work on or near exposed energized parts.
- GFCI protection purpose
- A ground-fault circuit interrupter detects small current imbalances and opens the circuit, protecting people from shock; it is required on temporary wiring receptacles.
- Lockout/tagout scope
- 29 CFR 1910.147 covers servicing and maintenance where unexpected energization, startup, or release of stored energy could injure an employee, excluding normal production operations.
- Cord-and-plug lockout exception
- Lockout/tagout does not apply when equipment is unplugged and the plug remains under the exclusive control of the employee performing the servicing.
- Annual LOTO periodic inspection
- The employer must inspect each energy control procedure at least annually, correct any deviations found, and certify the inspection with the date and employees involved.
- Machine guarding rule
- 1910.212 requires guarding at the point of operation, ingoing nip points, rotating parts, and flying chips or sparks, with guards affixed to the machine.
- Lockout verification step
- After isolating energy sources and applying locks, the authorized employee must verify isolation by attempting startup or testing for voltage before beginning work.
- Safety data sheet sections
- OSHA requires a standardized 16-section safety data sheet; section 4 covers first aid and section 8 covers exposure controls and personal protection.
- Employer PPE payment rule
- Employers must pay for required PPE, except non-specialty safety-toe footwear and non-specialty prescription safety eyewear that employees may wear off the job.
- Noise action level
- A hearing conservation program is required at an 8-hour time-weighted average of 85 dBA; the permissible exposure limit is 90 dBA with a 5 dB exchange rate.
- Respirator fit testing frequency
- Fit testing is required before initial use and at least annually thereafter, after a medical evaluation, using the same make, model, style, and size.
- Secondary container labeling
- A portable container must be labeled with the chemical identity and hazard information unless it is filled and used immediately by the employee who dispensed it.
- Permit space oxygen range
- Entry testing must show oxygen between 19.5 and 23.5 percent, flammable gas or vapor below 10 percent of the lower explosive limit, and other contaminants within limits.
- Powered industrial truck retraining
- Operators must be trained and evaluated, with refresher training and evaluation at least every three years or after an accident, near miss, or unsafe operation.
- Confined space attendant duties
- The attendant remains outside, monitors entrants and space conditions, maintains an accurate count, summons rescue services, and never enters to attempt a rescue.
- Fire extinguisher travel distance
- Class A extinguishers must be within 75 feet of employees and Class B extinguishers within 50 feet, with monthly visual checks and annual maintenance.