PA Water/Wastewater Operator study materials
PA Water/Wastewater Operator study resources

PA Water/Wastewater Operator cheat sheet

PA Water/Wastewater Operator · Keep the key ideas within reach.

Quick reference

Drinking Water Treatment

  • CT (mg/L·min) = disinfectant residual concentration × contact time; required CT depends on disinfectant type, pH, temperature, and the log inactivation credit sought.

  • Conventional train: coagulation → flocculation → sedimentation → filtration → disinfection → clear well/storage → distribution.

  • Rapid sand filtration rate 2–4 gpm/ft² (dual media up to 4–6 gpm/ft²); backwash at 15–20 gpm/ft² for roughly 20–25% bed expansion.

  • Combined filter effluent turbidity ≤0.3 NTU in at least 95% of monthly samples and never >1 NTU for conventional/direct filtration; individual filters ≤1 NTU.

  • Sedimentation surface overflow rate = flow ÷ surface area (gpm/ft²); typical conventional basin design 0.3–1.0 gpm/ft².

  • Free chlorine residual must be maintained at ≥0.2 mg/L (or detectable) in distribution; chlorine demand = dose applied − residual measured.

  • MCLs: nitrate 10 mg/L as N, nitrite 1 mg/L, fluoride 4.0 mg/L (SMCL 2.0), arsenic 0.010 mg/L, TTHM 0.080 mg/L, HAA5 0.060 mg/L; lead action level 0.015 mg/L, copper 1.3 mg/L.

  • Softening removes hardness with lime/soda ash; Langelier Saturation Index near 0 is balanced, positive indicates scaling tendency, negative indicates corrosion tendency.

  • Alum consumes about 0.45–0.5 mg/L of alkalinity as CaCO3 per mg/L of alum fed, so pH must be checked and adjusted after coagulant addition.

Quick reference

Drinking Water Distribution

  • Maintain at least 20 psi at all points in the distribution system at all times; typical operating pressure is 50–80 psi to satisfy customers and fire flow.

  • Unidirectional flushing must achieve ≥2.5 ft/s in the main to scour sediment and biofilm; flush one direction at a time with valves sequenced clean-to-dirty.

  • AWWA C651 new main disinfection: 25–50 mg/L chlorine, at least 24 hours contact, flush to ≤2.0 mg/L, then collect bacteriological samples.

  • Backflow protection hierarchy: air gap (highest) > reduced pressure zone assembly > double check valve > pressure vacuum breaker > atmospheric vacuum breaker.

  • Hazen-Williams head loss: h = 10.44 L Q^1.852 / (C^1.852 d^4.87); C ≈ 130–150 for new cement-lined or PVC pipe, 100 or lower for old unlined cast iron.

  • High water age depletes chlorine residual, raises TTHM/HAA5 formation, and can trigger nitrification in chloraminated systems (monitor ammonia and nitrite).

  • Thrust restraint is required at bends, tees, reducers, valves, and dead ends, using concrete thrust blocks bearing on undisturbed soil or restrained joints.

  • Coliform monitoring frequency scales with population served; every routine positive requires repeat samples within 24 hours at the original site plus upstream and downstream.

  • Storage tanks should be operated for turnover, screened at vents and overflows, and inspected regularly for sediment, corrosion, and security.

Quick reference

Wastewater Treatment

  • Common secondary effluent limits: 30 mg/L BOD5 and 30 mg/L TSS as monthly averages; many permits are considerably tighter.

  • Activated sludge targets: MLSS 2,000–4,000 mg/L, DO 1.5–2.5 mg/L, F/M 0.2–0.5 lb BOD/lb MLVSS-day, MCRT 5–15 days, SVI 80–150 mL/g.

  • F/M = lb BOD5 applied per day ÷ lb MLVSS under aeration; SVI = (30-minute settled volume in mL/L × 1000) ÷ MLSS in mg/L.

  • Primary clarifiers: overflow rate 600–1,200 gpd/ft², detention 1.5–2.5 hours, removing roughly 50–65% TSS and 25–40% BOD.

  • Secondary clarifiers: overflow rate 400–800 gpd/ft² and solids loading 20–30 lb/day/ft²; a rising sludge blanket signals need for more wasting.

  • Nitrification consumes about 7.14 mg/L alkalinity as CaCO3 and 4.57 mg/L oxygen per mg/L NH3-N oxidized, and can depress pH enough to stall nitrifiers.

  • Mesophilic anaerobic digestion: 95–99 °F, 30–60 day SRT, 40–50% volatile solids destruction, gas about 60–65% methane; keep VA/alkalinity ratio low.

  • Effluent chlorination dose = chlorine demand + desired residual; fecal coliform limits are often 200 CFU/100 mL as a monthly geometric mean.

  • Solids handling sequence: thicken (gravity or DAF) → stabilize (digestion, composting, lime) → dewater (belt press, centrifuge); typical cake 15–30% solids.

Quick reference

Wastewater Collection

  • Design gravity sewers for at least 2 ft/s at average daily flow (self-cleaning) and no more than about 10–15 ft/s to limit scour and H2S release.

  • Manning: Q = (1.486/n) A R^(2/3) S^(1/2); n ≈ 0.013 for PVC and concrete, 0.015 for vitrified clay and ductile iron.

  • Common minimum slopes: 4-inch lateral 1/4 inch per foot, 6-inch 1/8 inch per foot, 8-inch 1/16 inch per foot; confirm by computed velocity, not slope alone.

  • Infiltration is groundwater entering through defective pipes and joints; inflow is storm water entering through direct connections such as roof and area drains.

  • Acceptance testing: low-pressure air test per ASTM practice, deflection test with a mandrel sized to 95% of inside diameter (maximum 5% deflection), and CCTV inspection.

  • Force mains are designed for 2–5 ft/s; air/vacuum release valves go at high points, and surge is controlled with slow-closing valves or surge relief.

  • Excavation protective systems are required at 5 feet deep or more; spoil and equipment stay at least 2 feet from the trench edge and ladders within 25 feet of workers.

  • Manholes and wet wells are permit-required confined spaces: test for oxygen (19.5–23.5%), flammables under 10% LEL, and H2S under 10 ppm before and during entry.

  • H2S control includes ventilation, chemical addition (nitrate salts, iron salts, peroxide), and crown liners where sulfuric acid corrosion occurs above the waterline.