PA Water/Wastewater Operator flashcards
PA Water/Wastewater Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- CT is disinfectant residual in mg/L multiplied by contact time in minutes. Required CT varies with disinfectant, pH, temperature, and the log inactivation credit needed.
- Jar test
- A bench test that doses coagulant into raw water samples while varying dose and pH, then measures settled and filtered turbidity to find the best operating conditions.
- Filter L/d ratio
- Media bed depth divided by effective grain size, in the same units. Rapid sand filters usually need L/d of at least 1000 for stable media and good filtrate.
- Filter effluent turbidity limit
- Conventional and direct filtration plants must keep combined filter effluent at or below 0.3 NTU in 95 percent of monthly samples, never above 1 NTU.
- Surface overflow rate
- Clarifier flow divided by its surface area, usually expressed in gpm/ft². Conventional sedimentation basins are typically designed between 0.3 and 1.0 gpm/ft².
- Fluoride standards
- The fluoride MCL is 4.0 mg/L and the secondary standard is 2.0 mg/L. About 0.7 mg/L is the recommended optimal concentration for dental protection.
- TTHM MCL
- Total trihalomethanes may not exceed 0.080 mg/L (80 micrograms per liter), evaluated as a locational running annual average at each compliance monitoring site.
- Alum alkalinity demand
- Alum consumes roughly 0.45 to 0.5 mg/L of alkalinity as CaCO3 per mg/L of alum fed, lowering pH and possibly requiring lime or caustic addition.
- Minimum distribution pressure
- Distribution systems must maintain at least 20 psi at all points at all times; typical operating pressures are 50 to 80 psi to serve customers and fire flows.
- Unidirectional flushing
- Flushing one direction through isolated main segments at 2.5 ft/s or more scours sediment and biofilm loose so it can be discharged rather than redeposited.
- RPZ assembly
- A reduced pressure zone backflow preventer uses two check valves with a relief valve between them, protecting against both backpressure and backsiphonage at high-hazard connections.
- AWWA C651 disinfection
- New mains are chlorinated at 25 to 50 mg/L for at least 24 hours, flushed until residual falls to 2.0 mg/L or less, then sampled for coliform bacteria.
- Water age
- The average time water spends in pipes and storage. High age depletes disinfectant residual, increases disinfection byproducts, and can trigger nitrification in chloraminated systems.
- Hazen-Williams head loss
- An empirical pipe friction equation: h equals 10.44 times length times flow to the 1.852 power, divided by C to the 1.852 times diameter to the 4.87.
- Thrust block
- Concrete placed against undisturbed soil behind tees, bends, and caps to resist the unbalanced pressure thrust that would otherwise separate pipe joints.
- Coliform repeat sampling
- A routine total coliform positive requires repeat samples within 24 hours at the original site plus upstream and downstream locations, with more repeats for each positive repeat.
- Food to microorganism ratio
- F/M equals pounds of BOD5 applied per day divided by pounds of MLVSS in the aeration basin; conventional activated sludge operates near 0.2 to 0.5.
- Sludge volume index
- SVI equals the 30-minute settled sludge volume in mL/L times 1000, divided by MLSS in mg/L; 80 to 150 mL/g indicates good settling.
- Mean cell residence time
- MCRT, or solids retention time, is the mass of solids in the aeration system divided by the mass wasted and lost daily; conventional plants run 5 to 15 days.
- Nitrification alkalinity demand
- Oxidizing ammonia to nitrate consumes about 7.14 mg/L of alkalinity as CaCO3 and 4.57 mg/L of oxygen per mg/L of ammonia nitrogen, lowering pH.
- Primary clarifier design
- Primary clarifiers typically use 600 to 1,200 gpd/ft² overflow rates and 1.5 to 2.5 hours detention, removing about 50 to 65 percent TSS and 25 to 40 percent BOD.
- Solids loading rate
- Solids applied to a clarifier per day divided by its surface area. Secondary clarifiers in activated sludge plants are typically designed for 20 to 30 lb/day/ft².
- Mesophilic anaerobic digestion
- Digesters held near 95 degrees F with 30 to 60 days solids retention destroy 40 to 50 percent of volatile solids and produce gas about 60 to 65 percent methane.
- Aeration basin dissolved oxygen
- Activated sludge aeration is normally held at 1.5 to 2.5 mg/L dissolved oxygen; nitrifying systems need about 2 mg/L or more to support nitrifiers.
- Minimum self-cleaning velocity
- Gravity sanitary sewers are designed to reach at least 2 ft/s at average daily flow so solids stay suspended, while staying below about 10 ft/s to limit scour.
- Manning equation
- Flow equals 1.486 divided by n, times area, times hydraulic radius to the two-thirds power, times slope to the one-half power; n is about 0.013 for PVC.
- Infiltration versus inflow
- Infiltration is groundwater seeping through defective pipes, joints, and manholes. Inflow is storm water entering directly through roof drains, area drains, and unsealed covers.
- Low-pressure air test
- A gravity sewer acceptance test where plugged sections are pressurized with air; the time allowed for a set pressure drop depends on pipe size, length, and specifications.
- Mandrel deflection test
- A rigid mandrel sized to 95 percent of the pipe inside diameter is pulled through flexible sewer pipe to prove deflection does not exceed 5 percent.
- Force main velocity
- Pumped force mains are usually designed for 2 to 5 ft/s; slower flow lets solids settle, while faster flow increases friction loss and surge pressures.
- Excavation five-foot rule
- OSHA requires a protective system such as sloping, benching, shoring, or a trench shield for excavations 5 feet deep or more, or any depth with identified hazards.
- Smoke testing
- Forcing non-toxic smoke into a sewer section shows where it escapes to the surface, revealing illegal storm connections, broken pipe, and defective manholes.