PA Water/Wastewater Operator · Get comfortable with the vocabulary.

Coagulation

Adding a chemical such as alum or ferric chloride to raw water and mixing it fast so tiny suspended particles and color clump together. Those clumps can then be removed by settling and filtration.

Related: Flocculation, Jar test, Sedimentation
Flocculation

Slow, gentle stirring that lets chemically treated particles bump into each other and grow into larger, heavier clumps called floc. These clumps settle faster and are easier for filters to catch.

Related: Coagulation, Sedimentation, Filtration
Sedimentation

A quiet basin where water moves slowly enough that floc and other solids sink to the bottom and collect as sludge. The clearer water flowing off the top goes on to the filters.

Related: Flocculation, Filtration, Coagulation
Filtration

Passing settled water through a bed of sand, anthracite, or other granular media so remaining fine particles and some pathogens are trapped. Filters are a key physical barrier before disinfection.

Related: Backwash, Turbidity, Sedimentation
Backwash

Reversing flow upward through a filter bed to wash out the solids it has captured. Operators start a backwash when head loss or filtered-water turbidity reaches a set trigger point.

Related: Filtration, Turbidity
Turbidity

A measure of how cloudy water looks because of suspended particles, reported in nephelometric turbidity units (NTU). Cloudy water can hide pathogens from disinfectants and is closely regulated.

Related: Filtration, Disinfection, Backwash
Disinfection

A treatment step that inactivates or kills harmful organisms, usually with chlorine, chloramine, ozone, or ultraviolet light. It works best after particles have been removed by settling and filtration.

Related: CT value, Chlorine residual, Turbidity
CT value

The disinfectant concentration in mg/L multiplied by the effective contact time in minutes. Required CT depends on water temperature, pH, and the target organism, and shows whether disinfection is adequate.

Related: Disinfection, Chlorine residual
Chlorine residual

The chlorine still left in the water after it has reacted with impurities. A measurable residual keeps water protected as it travels through pipes and is required in the distribution system.

Related: Disinfection, CT value, Water main
Jar test

A bench-scale test that mixes a raw water sample with several coagulant doses and stirs it through fast and slow stages. It shows which dose produces the best floc and settling.

Related: Coagulation, Flocculation, Turbidity
Disinfection byproducts (THMs)

Chemicals such as trihalomethanes that form when chlorine reacts with natural organic matter in water. Their levels are limited by regulation, so plants must balance disinfection against byproduct formation.

Related: Disinfection, Chlorine residual, Turbidity
Water main

A buried pipe in the distribution network that carries finished water along streets and blocks. Mains come in sizes and materials such as ductile iron, PVC, and cast iron, and must stay pressurized.

Related: Gate valve, Fire hydrant, Unidirectional flushing
Gate valve

A valve with a sliding gate used to start, stop, or isolate flow in a main. It is normally kept fully open or fully closed so the gate is not damaged by throttling.

Related: Water main, Fire hydrant
Fire hydrant

A valved connection on a water main that lets fire crews draw large flows and lets utility staff flush mains and test pressure. Hydrants need periodic inspection, lubrication, and draining.

Related: Water main, Unidirectional flushing
Water hammer

A pressure surge caused by a sudden stop or change in water velocity, such as rapid valve closure. The shock can crack pipes and damage fittings, so valves are closed slowly.

Related: Gate valve, Water main
Cross-connection

Any actual or potential link between the drinking water system and a source of contamination, such as a hose sitting in a bucket of chemicals. Cross-connections are the main reason backflow can occur.

Related: Backflow prevention assembly, Chlorine residual
Backflow prevention assembly

A tested device, such as a reduced-pressure zone assembly or an air gap, that stops contaminated water from reversing into the drinking water supply. It must be tested on a schedule set by the state.

Related: Cross-connection, Water main
Booster pump station

Pumps placed along the distribution system to raise pressure for higher ground or distant areas. They usually draw from a storage tank so suction pressure stays positive.

Related: Elevated storage tank, Water main
Elevated storage tank

A tall tank that holds finished water and uses gravity to keep steady pressure in the distribution system. Its level rises and falls with demand and provides supply during fires and outages.

Related: Booster pump station, Water main, Fire hydrant
Unidirectional flushing

Opening hydrants in a planned sequence so water runs fast in one direction through a section of main. The higher velocity scours out sediment and stale water without stirring up other areas.

Related: Fire hydrant, Water main, Chlorine residual
Activated sludge

A process where wastewater is mixed with air and a dense community of microorganisms that consume organic matter. The mixture is settled afterward, and some settled organisms are returned to keep the process going.

Related: Mixed liquor suspended solids (MLSS), Return activated sludge (RAS), Secondary clarifier
Mixed liquor suspended solids (MLSS)

The concentration of solids, mostly bacteria, suspended in the aeration tank. Operators measure MLSS to control how much biomass is kept in the activated sludge process.

Related: Activated sludge, Return activated sludge (RAS), Sludge volume index (SVI)
Return activated sludge (RAS)

Sludge settled in the secondary clarifier that is pumped back to the aeration tank to maintain the needed population of microorganisms. The portion not returned is wasted as excess sludge.

Related: Activated sludge, Secondary clarifier, Mixed liquor suspended solids (MLSS)
Secondary clarifier

A settling tank after aeration where activated sludge floc sinks and separates from the treated water. The clear overflow goes on to disinfection while settled sludge is returned or wasted.

Related: Activated sludge, Return activated sludge (RAS), Sludge volume index (SVI)
Mean cell residence time (MCRT)

Also called sludge age, the average time solids stay in the treatment system, found by dividing the solids inventory by the solids leaving each day. It strongly affects settling and nitrification.

Related: Return activated sludge (RAS), Food-to-microorganism ratio (F/M), Nitrification
Food-to-microorganism ratio (F/M)

The pounds of BOD entering the aeration tank each day divided by the pounds of microorganisms there. A low ratio usually means more complete treatment and better nitrification.

Related: Mean cell residence time (MCRT), BOD, Mixed liquor suspended solids (MLSS)
BOD

Biochemical oxygen demand, a test of how much oxygen microorganisms use while breaking down organic matter in a sample over five days. It is the standard measure of organic strength in wastewater.

Related: Food-to-microorganism ratio (F/M), Total suspended solids (TSS)
Total suspended solids (TSS)

The weight of solids captured on a filter from a measured sample, reported in mg/L. In wastewater it shows how well settling and other solids-removal steps are working.

Related: BOD, Secondary clarifier, Sludge volume index (SVI)
Sludge volume index (SVI)

A number from a settled-sludge test that shows whether activated sludge settles well. A high SVI points to bulking sludge that may wash out over the clarifier weir.

Related: Secondary clarifier, Return activated sludge (RAS), Mixed liquor suspended solids (MLSS)
Nitrification

The two-step biological conversion of ammonia to nitrite and then to nitrate by specific bacteria. It consumes oxygen and alkalinity and is often required for plants discharging to sensitive waters.

Related: Mean cell residence time (MCRT), Activated sludge
Anaerobic digestion

Holding sludge in a heated tank without oxygen so bacteria break down organic solids, shrinking the volume and producing methane gas. It also reduces pathogens before the sludge is dewatered or reused.

Related: Activated sludge, Total suspended solids (TSS)
Gravity sewer

A pipe that carries wastewater downhill by slope alone, using no pumps. It must be laid at a grade that keeps flow fast enough to move solids but not so fast that it scours the pipe.

Related: Manhole invert, Lift station, Infiltration and inflow (I/I)
Lift station

A facility with pumps and a wet well that raises wastewater so it can flow onward, often through a force main. Lift stations serve areas too flat or too deep for gravity sewers.

Related: Gravity sewer, Sanitary sewer overflow (SSO), Infiltration and inflow (I/I)
Infiltration and inflow (I/I)

Infiltration is groundwater seeping into sewers through cracks and joints; inflow is storm water entering through direct connections such as downspouts or manhole covers. Both add clean water the plant must treat.

Related: Sanitary sewer overflow (SSO), Gravity sewer, Lift station
Sanitary sewer overflow (SSO)

A release of untreated wastewater from the collection system before it reaches the plant, often caused by blockages, pump failures, or heavy rain. Overflows must be reported and corrected quickly.

Related: Infiltration and inflow (I/I), Lift station, Fats, oils, and grease (FOG)
Manhole invert

The shaped channel at the bottom of a manhole that carries flow smoothly from one pipe to the next. A poorly built invert creates turbulence and lets solids build up.

Related: Gravity sewer, Fats, oils, and grease (FOG), Hydrogen sulfide (H2S)
Fats, oils, and grease (FOG)

Cooking grease and similar materials that cool and harden inside sewers, narrowing the pipe and causing blockages. Local programs require grease traps at restaurants to keep FOG out of the system.

Related: Sanitary sewer overflow (SSO), Manhole invert
Hydrogen sulfide (H2S)

A toxic gas with a rotten-egg odor that forms when sewage turns septic inside a pipe. In the damp air above the flow it becomes sulfuric acid that eats concrete, and it is a serious worker hazard.

Related: Confined space entry, Manhole invert
Confined space entry

Going into a manhole, wet well, or tank that has limited openings and may hold dangerous air. Entry requires a permit, air testing, ventilation, a standby attendant, and rescue equipment.

Related: Hydrogen sulfide (H2S)