PE Electrical Power study materials
PE Electrical Power study resources

PE Electrical Power study plan

PE Electrical Power · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

General Power Engineering (circuit analysis, measurement and instrumentation)

  • Solve 40 circuit-analysis problems covering nodal and mesh analysis, Thevenin and Norton equivalents, and superposition, logging accuracy by subtopic.

  • Compute three-phase real, reactive, and apparent power for balanced and unbalanced wye and delta loads without consulting notes.

  • Convert between per-unit and actual quantities for single-phase and three-phase systems, showing each base-selection step explicitly.

  • Build a one-page formula sheet for circuit analysis and per-unit conversion, then verify every entry against 10 solved problems.

Your checkpoint

Score at least 75% on a 25-question, 60-minute timed quiz covering circuit analysis and per-unit conversion.

Week 2

General Power Engineering (circuit analysis, measurement and instrumentation) & Power System Analysis, Protection, and Power Electronics

  • Interpret CT and PT ratios, burden, and accuracy class to calculate secondary currents and metering error across 15 instrument-transformer problems.

  • Analyze single-phase and three-phase rectifier circuits, calculating average and RMS output voltage, ripple factor, and diode or thyristor ratings.

  • Derive duty-cycle relationships for buck, boost, and buck-boost converters, then compute inductor ripple current for 10 design cases.

  • Estimate how oscilloscope, DMM, and power-analyzer errors propagate into a measured power value for three measurement setups.

Your checkpoint

Produce a two-page comparison table of rectifier and DC-DC converter topologies with fully worked numerical examples for each row.

Week 3

Power System Analysis, Protection, and Power Electronics

  • Build positive-, negative-, and zero-sequence networks for eight fault scenarios and compute fault currents for bolted three-phase, single-line-to-ground, line-to-line, and double-line-to-ground faults.

  • Set up a per-unit load-flow model for a five-bus system and verify real and reactive power balance at every bus.

  • Convert phase voltages and currents into symmetrical components and reconstruct phase quantities for 10 datasets.

  • Derive sequence impedances for transformers and lines under different grounding configurations, documenting each assumption.

Your checkpoint

Complete a six-problem fault-analysis set with sequence networks sketched and calculated fault currents within 5% of reference answers.

Week 4

Power System Analysis, Protection, and Power Electronics

  • Set overcurrent and differential relay pickup and time-dial values for a three-bus radial system and a looped system, checking coordination margins at each pair.

  • Select breaker interrupting ratings and CT ratios that match the fault duties computed in Week 3.

  • Apply symmetrical-component logic to distance and differential protection schemes across eight relay scenarios.

  • Diagnose coordination failures in five given settings tables and propose corrected settings with justification.

Your checkpoint

Submit a complete coordination study for a four-bus system showing relay settings, numerically described time-current characteristics, and margin calculations.

Week 5

Rotating Machines and Electromagnetic Devices

  • Compute transformer equivalent-circuit parameters from open-circuit and short-circuit tests and predict voltage regulation at specified loads and power factors.

  • Analyze three-phase induction motor torque-speed behavior, starting current, and efficiency at 10 operating points.

  • Determine synchronous generator voltage regulation using the EMF, MMF, and Potier methods for several load power factors.

  • Calculate load sharing for parallel transformers and paralleled generators, including circulating current from mismatched tap settings.

Your checkpoint

Build a reusable machine-parameter calculation template and use it to solve 12 machine problems with at least 80% accuracy.

Week 6

Rotating Machines and Electromagnetic Devices & Transmission and Distribution

  • Compute magnetic-circuit reluctance, flux, and inductance for eight geometries, including air gaps and fringing allowances.

  • Calculate eddy-current and hysteresis losses and explain how lamination thickness and core material affect each component.

  • Analyze DC machine and single-phase motor performance at 10 operating conditions, including starting and speed control.

  • Calculate transmission-line series impedance and shunt admittance from conductor geometry, bundling, and phase spacing.

Your checkpoint

Complete a 15-problem mixed set on magnetic devices and line parameters, scoring at least 75%.

Week 7

Transmission and Distribution

  • Calculate voltage regulation and line losses for short, medium, and long transmission lines using the appropriate model for each.

  • Size shunt capacitors and series reactors for voltage support across eight load scenarios, verifying against voltage limits.

  • Compute substation grounding-grid resistance and check step and touch voltages against allowable limits.

  • Select conductor size and overcurrent device ratings for a distribution feeder given load growth and available fault current.

Your checkpoint

Produce a three-page transmission and distribution design summary for a five-bus feeder covering voltage profile, losses, and grounding check.

Week 8

General Power Engineering (circuit analysis, measurement and instrumentation) & Rotating Machines and Electromagnetic Devices & Transmission and Distribution & Power System Analysis, Protection, and Power Electronics

  • Complete an 80-question, four-hour full-length practice exam under strict timed conditions.

  • Categorize every missed question by domain and write a corrective note explaining the underlying concept and error.

  • Re-solve 20 previously missed problems without notes to confirm retention.

  • Finalize a one-page master formula and reference sheet spanning all four domains.

Your checkpoint

Achieve at least 75% on the full-length practice exam and submit an error log with a corrective action for every missed item.

Milestones

Week 4: Score at least 70% on a 40-question timed mid-plan assessment covering Domains 1 and 4; if below, schedule two remediation blocks during Weeks 5 and 6.

Week 6: Confirm all machine and magnetic-device calculation templates produce answers within 5% of reference solutions on 10 randomly selected problems.

Week 8: Score at least 75% on the full-length practice exam with no single domain below 65%; otherwise repeat targeted domain blocks before the exam date.