MARINA Second Engineer / Chief Engineer Theoretical Exam flashcards
MARINA Second Engineer / Chief Engineer Theoretical Exam · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Diesel cycle thermal efficiency
- Efficiency = 1 − (1/r^(γ−1)) · (ρ^γ − 1)/(γ(ρ − 1)), where r is compression ratio, ρ the cut-off ratio, and γ the specific heat ratio. Higher compression ratio improves efficiency.
- Brake specific fuel consumption
- Mass of fuel consumed per unit of brake power per hour, usually in g/kWh. Large slow-speed two-stroke engines typically achieve 160–175 g/kWh at rated load.
- Propeller law
- For a fixed-pitch propeller, absorbed power varies with the cube of shaft speed and thrust with the square. A 10% rpm increase raises power demand by about 33%.
- Governor speed droop
- The percentage speed rise from full load to no load at rated setting. Propulsion engines typically use 3–5% droop; isochronous mode (zero droop) is used for alternators.
- Starting air requirement
- SOLAS requires sufficient starting air for at least 12 consecutive starts of a reversible engine, or 6 for a non-reversible engine, normally from air bottles at about 30 bar.
- Crankcase oil mist detector
- A device that samples crankcase atmosphere and alarms at about 2.5% of the lower explosive limit. On alarm, reduce load and investigate; never open doors before cooling.
- Pump affinity laws
- For a centrifugal pump at constant impeller diameter, flow varies with speed, head with speed squared, and power with speed cubed. These laws guide speed control and throttling decisions.
- Net positive suction head
- NPSH available equals atmospheric minus vapour pressure head, plus static suction head, minus friction losses. It must exceed the pump's NPSH required to avoid cavitation.
- Boiler low-water interlock
- A safety device that cuts off fuel to the boiler when water level falls below a safe limit. Firing a boiler with low water level risks overheating and explosion.
- Steering gear drill interval
- SOLAS requires emergency steering drills every three months, including communication with the bridge and operation of the auxiliary steering gear from the steering flat.
- Three-phase power formula
- Active power P = √3 · line voltage · line current · power factor. A low power factor increases current for the same kW, raising cable and generator loading.
- Synchronous generator paralleling
- Before closing the breaker, match voltage, frequency, phase sequence, and phase angle. After paralleling, governor droop determines how active load is shared between generators.
- Insulation resistance minimum
- Low-voltage circuits should normally read at least 1 MΩ when tested at 500 V DC. Readings are recorded and trended; a falling trend indicates moisture or deterioration.
- IT earthing system
- A distribution with no direct neutral earth, standard on ships. A single earth fault does not trip the circuit but must be found and cleared before a second fault occurs.
- STCW rest hour limits
- A minimum of 10 hours rest in any 24-hour period and 77 hours in any 7-day period. Rest may be split into at most two periods, one of at least 6 hours.
- UMS alarm response
- In an unattended machinery space, the engineer on call must respond within the time stated in standing orders. Alarms and safety systems are tested before entering UMS mode.
- Bridge order acknowledgement
- The engineer repeats the order, executes it, and reports back. This closed-loop communication prevents misunderstanding during manoeuvring and is standard watchkeeping practice.
- Bunkering checklist items
- Agreed transfer rate, tank soundings before and after, scuppers plugged, overflow tank monitored, communication with the barge, and drip trays in place.
- Condition-based maintenance
- Maintenance triggered by measured condition rather than fixed intervals, using vibration analysis, oil analysis, thermography, and performance trending to decide when intervention is needed.
- Oil analysis parameters
- Viscosity, water content, total base number, insolubles, and wear metals such as iron, copper, lead, tin, and silicon. Trends over time matter more than single readings.
- Class special survey interval
- Special surveys are normally conducted at five-year intervals, with annual and intermediate surveys in between. Continuous survey machinery spreads items across the cycle.
- Oily water separator limit
- MARPOL Annex I permits discharge of processed bilge water only at 15 ppm or less, through an approved separator with alarm and automatic stopping device, outside special areas.
- MARPOL sulphur limits
- Fuel sulphur must not exceed 0.50% m/m globally and 0.10% m/m in emission control areas. Compliance is by low-sulphur fuel, scrubber, or alternative fuel, with records.
- Oil record book entry
- Each transfer, disposal, or separator operation must be recorded without delay and signed. Falsifying entries is a criminal offence in most jurisdictions.
- Ballast water management
- The BWM Convention requires D-1 exchange or D-2 treatment, a ballast water management plan, a record book, and a valid certificate on board.
- SOLAS chapter structure
- Chapter II-1 covers subdivision and machinery, II-2 fire safety, IX the ISM Code, and XI-1/2 surveys and port state control. Engineers should know which chapter applies.
- ISM Code requirement
- A Safety Management System with documented procedures, a designated person ashore, and defined master's authority. Non-conformities are recorded and closed out.
- Port state control detention
- When deficiencies are serious, the port state may detain the ship until rectified. Detentions are published in regional databases and affect future inspections.
- Metacentric height formula
- GM = KM − KG. Positive GM gives initial stability; the GZ curve area gives dynamical stability, and IMO criteria require area to 30° of at least 0.055 m·rad.
- Free surface effect
- Liquid in a partly filled tank reduces effective GM by free surface correction equal to the tank's second moment of area times density divided by displacement. Subdivision reduces it.
- Fire classes
- Class A solid, B liquid, C gas, D metal, and F cooking oil. Fixed systems include CO2, foam, water mist, and dry powder, chosen to suit the fuel and space.
- Enclosed space entry testing
- Test oxygen (about 20.9%), hydrocarbons, carbon monoxide, and hydrogen sulphide before entry. Continuous monitoring and a standby person at the entrance are required.