Ohm's law
Voltage equals current multiplied by resistance (V = I × R); power equals voltage times current (P = V × I). Used to size wire and verify circuit loads.
Supervised alarm zone
A detection circuit continuously monitored by the panel for opens and shorts, typically through an end-of-line resistor, so a wiring fault annunciates as a trouble condition.
Normally closed intrusion loop
Devices wired in series so the loop carries current in the normal state; the panel signals an alarm when a device opens the circuit.
Fail-safe lock
Door hardware that is locked while energized and releases automatically when power is removed, permitting egress during a fire alarm or power failure.
End-of-line resistor
A resistor at the far end of a supervised zone that produces the reference current the panel expects; its value must match the programmed zone type.
Class 2 circuit
A power-limited circuit under NEC Article 725 whose energy is limited so it presents reduced fire and shock hazard; typical for alarm and signaling wiring.
Cat6 channel length limit
A horizontal cable channel, including all patch and equipment cords, may not exceed 100 meters (328 feet); the permanent link is limited to 90 meters.
RS-485 bus limits
Up to roughly 1200 meters (4000 feet) of twisted pair in a daisy chain, with 120-ohm termination at both physical ends and no star branches.
T568B pin order
Pins 1 through 8 are white-orange, orange, white-green, blue, white-blue, green, white-brown, brown; used for RJ45 plugs, jacks and patch panels.
PoE 802.3at budget
Power over Ethernet Plus delivers 30 watts at the power sourcing equipment and guarantees 25.5 watts at the powered device over two pairs.
Standby battery sizing
Amp-hour capacity equals standby current times standby hours plus alarm current times alarm hours, multiplied by a 1.25 derating factor for aging.
Plenum-rated cable
Cable listed CMP, required in air-handling spaces because of its low smoke and flame-spread characteristics; unlisted substitutes are not permitted in plenums.
Sealed lead-acid service life
Standby batteries typically last three to five years; a load-test capacity below 80 percent of the rated amp-hour value indicates replacement is due.
Video storage estimate
One camera recording at 1 Mbps produces about 10.8 gigabytes per day; multiply by camera count and retention days for total storage.
Cross-zoning
An alarm verification method requiring two detectors in the same area to trip within a defined time window before the panel transmits an alarm.
NTP time synchronization
Network time protocol keeps panels, recorders and servers on a common clock so events in different logs can be correlated during an investigation.
Daily test signal
A scheduled automatic transmission from the protected premises to the monitoring center; its absence is treated and reported as a communication trouble.
Resistance measurement rule
Resistance is measured only with power removed and the component isolated from parallel paths; otherwise the meter reading is invalid.
Half-split fault isolation
Dividing a circuit at its midpoint, testing each half, and repeating on the faulty half locates a fault in a logarithmic number of tests.
Time domain reflectometer
A test instrument that sends a pulse down a cable and measures reflection delay to report the distance to an open, short or impedance mismatch.
Ground fault on a loop
Unintended leakage to earth, detected by measuring resistance from each conductor to ground; the low reading identifies the faulted leg.
Ping test
An ICMP echo request sent to an IP device that confirms network reachability and round-trip time, separating addressing faults from hardware faults.
NFPA 72 scope
The national code covering selection, installation, testing, inspection and maintenance of fire detection and alarm systems and emergency communications systems.
NFPA 731 scope
The installation standard for premises security systems, covering intrusion detection, access control and surveillance design, installation, testing and maintenance.
NEC Article 760
The article governing fire alarm system wiring and cable types such as FPL, FPLR and NPLF, including installation methods and marking requirements.
Lockout tagout
The OSHA 1910.147 requirement to isolate, lock and tag all hazardous energy sources before servicing equipment, verified by an attempted start.
Fall protection trigger
General industry requires fall protection at four feet above a lower level; construction work requires it at six feet above a lower level.
Firestopping
A listed material and system used to seal penetrations of rated walls and floors so the assembly's fire resistance rating is restored.
Record of Completion
The NFPA 72 document listing installed devices, system features and test results, signed by the installing contractor and the owner's representative.
As-built drawings
Drawings revised during installation to show actual device locations, addresses, cable routes and panel positions as they exist in the field.
Punch list
A written record of outstanding deficiencies and incomplete work, with an assigned owner and due date, closed by signature before project acceptance.
Handoff training record
Documentation of the customer training session including date, topics covered, attendee names and signatures, serving as proof of knowledge transfer.