- Floor Area Ratio
- Total gross floor area of all storeys divided by the plot area. Zoning bylaws cap FAR to control building bulk and population density on a site.
- Setback
- The minimum horizontal distance required between the property boundary and the building line. It is fixed by zoning regulation and provides light, air, and privacy.
- Solar noon orientation
- In the northern hemisphere the sun is due south at solar noon. South facades gain most winter sun and are easiest to shade in summer with horizontal devices.
- Ramp gradient limit
- A slope of 1:12 is the usual maximum for unassisted wheelchair use. Slopes of 1:20 or flatter are preferred where site space allows.
- Water-cement ratio
- The mass of water divided by the mass of cement in a concrete mix. Lower ratios increase strength and reduce permeability but make the fresh mix less workable.
- Damp-proof course
- A continuous impervious layer built into a wall near ground level to stop moisture rising by capillary action into the masonry above.
- Cavity wall ties
- Metal ties connecting the inner and outer leaves of a cavity wall. They transfer lateral load and must be spaced and sloped per code to shed water outward.
- Lintel load triangle
- The assumption that masonry above an opening loads the lintel within a 45-degree triangle rising to lintel level, rather than the full wall height.
- Section modulus
- A geometric property of a cross-section equal to the second moment of area divided by the distance to the extreme fibre. Bending stress equals moment divided by section modulus.
- Euler buckling load
- The critical axial load at which a slender column buckles, equal to pi squared times EI divided by the square of the effective length.
- Simply supported beam moment
- For a uniformly distributed load w over span L, the maximum bending moment is wL squared divided by eight, occurring at midspan.
- Slenderness ratio
- The effective length of a compression member divided by its radius of gyration. Higher values mean greater susceptibility to buckling and lower capacity.
- Trap water seal
- A retained depth of water in a plumbing trap, commonly 50 to 75 millimetres, that blocks sewer gas from entering the building.
- Diversity factor
- The ratio of maximum simultaneous demand to the sum of all connected loads. It prevents electrical supply and cable sizing from being grossly oversized.
- Vent pipe function
- A pipe connecting the drainage stack to outside air. It equalizes pressure so water flow does not siphon the trap seal, and terminates above roof level.
- U-value
- Thermal transmittance, the reciprocal of total thermal resistance. It measures heat flow in watts per square metre per kelvin; lower values indicate better insulation.
- Daylight factor
- Internal illuminance at a point divided by simultaneous external horizontal illuminance under an unobstructed overcast sky, expressed as a percentage.
- Embodied carbon
- The greenhouse gas emissions associated with extracting, manufacturing, transporting, and assembling building materials, plus their eventual disposal or reuse.
- Psychrometric chart
- A graph plotting dry-bulb temperature against moisture content, used to locate the comfort zone and to analyse heating, cooling, humidification, and dehumidification processes.
- Practical completion
- The certified stage at which the works are substantially complete and fit for purpose. It transfers possession and risk to the client and starts the defects liability period.
- Professional indemnity insurance
- Insurance covering the architect against claims for negligent design, errors, and omissions in professional services. It does not cover contractor workmanship defects.
- Architect's instruction
- The formal written mechanism by which the architect directs a variation or clarifies the works. Oral instructions should be confirmed in writing within the contract period.
- Retention
- A percentage withheld from each interim payment as security for performance, commonly released in two parts at practical completion and after the defects period.
- Certificate of occupancy
- A document issued by the building authority after inspection confirming that a completed building complies and may lawfully be occupied for its approved use.
- Paramount duty to public
- The architect's obligation to protect public health, safety, and welfare takes precedence over commercial loyalty to the client when the two conflict.
- Street enclosure ratio
- Building height divided by street width. Ratios roughly between one to one and one to three produce a comfortable, well-defined sense of urban enclosure.
- Active frontage
- Ground-floor building edge with doors, windows, and activity facing the street. It supports natural surveillance and street life, unlike blank walls or car parks.
- Transit-oriented development
- Higher-density, mixed-use development clustered within a walkable radius, commonly 400 to 800 metres, of a public transport station to reduce car dependence.
- Net residential density
- Dwelling units per hectare of land devoted only to housing, excluding roads, open space, and community facilities counted in gross density.
- Inclusionary zoning
- A planning requirement that a set percentage of units in a new residential development be provided as affordable housing, often in exchange for density bonuses.
- Critical path
- The longest duration sequence of dependent activities through a project network. Any delay on it delays overall completion, and its total float is zero.
- Cost performance index
- Earned value divided by actual cost. A value below one indicates the project is spending more than the value of work completed to date.
- Liquidated damages
- A pre-agreed sum payable by the contractor for delay, representing a genuine estimate of the client's loss. It must not be a punitive penalty.