C&G 2079-11 F-Gas Category I study plan
C&G 2079-11 F-Gas Category I · Give each week a clear focus.
8 weeks · About 7 hours per week
F-gas and ODS regulations, legal duties and environmental impact
List the core legal duties of a certified F-gas operative and state which activities are restricted to certified personnel and certified companies
Explain global warming potential and ozone depletion potential, then rank the main refrigerant families (HFCs, HFOs, CO2, ammonia, hydrocarbons, CFCs/HCFCs) by environmental impact
Convert refrigerant charge weights into CO2-equivalent tonnes using GWP values and apply the resulting thresholds to real system examples
Identify the environmental consequences of refrigerant venting and the correct legal route for disposing of recovered ODS and F-gas
Summarise the penalties, enforcement routes and record-retention periods that apply to non-compliance
Your checkpoint
A one-page GWP-to-CO2e conversion table with five worked examples plus 15 self-written questions on legal duties, scored at 80% or better
F-gas and ODS regulations, legal duties and environmental impact & Leak checking, containment, record keeping and reporting obligations
Build a leak-check frequency matrix from CO2e band, system type and whether a leak detection system is fitted
State the statutory intervals for re-checking after a leak is repaired and for verifying that a repaired leak is sealed
Complete a compliant F-gas equipment record for a fictitious system, including charge history, leak checks and repairs
Describe who must be notified, in what form and within what timeframe when a reportable leak occurs
Explain the labelling, containment and record-transfer duties that apply when a system changes hands
Your checkpoint
A leak-check schedule matrix covering five system sizes plus a fully completed sample equipment record and leak report
Installation, commissioning, pressure testing and evacuation of RAC systems
Plan the installation sequence for a split and a small packaged system, listing the isolation, brazing, pipework and electrical checks required at each stage
Calculate strength-test and tightness-test pressures for R410A, R32 and R134a systems and distinguish when each test is mandatory
Specify the correct test gas, regulator, gauge class and test duration, and state why oxygen and air must never be used
Write an evacuation and dehydration procedure including triple evacuation, vacuum hold test and micron-level acceptance criteria
Draft a commissioning checklist covering charge verification, superheat/subcool, safety controls and handover documentation
Your checkpoint
A written commissioning procedure with calculated test pressures and vacuum targets for three refrigerants, plus 15 pressure and vacuum calculation problems solved correctly
Installation, commissioning, pressure testing and evacuation of RAC systems & Servicing, maintenance, refrigerant recovery, recycling and decommissioning
Explain why pipework is nitrogen-purged during brazing and describe the checks that detect a poor purge
Select and justify test instruments, stating the accuracy, calibration and range requirements for pressure and vacuum measurement
Compare vapour, liquid and push-pull recovery methods and select the right one for a given system and refrigerant state
Calculate the maximum fill weight for a recovery cylinder from its water capacity and the refrigerant density, applying the 80% fill limit
Identify the hazards and controls for recovering a flammable refrigerant from a system containing residual charge
Your checkpoint
A timed 40-question mixed paper across domains 1, 3 and 4, completed in 60 minutes with a score of 75% or better and an error log in your own words
Servicing, maintenance, refrigerant recovery, recycling and decommissioning
Distinguish recovery, recycling, reclaiming and destruction, and state which processes a Cat I operative may carry out on site
Write a decommissioning procedure for a system containing ODS, including pump-down, isolation, oil handling and cylinder labelling
Describe how recovered refrigerant is documented, stored, transported and consigned for destruction or reclaim
Explain the risks of mixing refrigerant types and the checks that prevent cross-contamination of recovery cylinders
Outline the correct handling and disposal routes for contaminated oil, filter driers and contaminated components
Your checkpoint
A written recovery and decommissioning procedure plus 12 scenario questions on recovered-refrigerant handling, scored at 80% or better
Refrigerant safety, cylinder handling, PPE and risk assessment
Classify the main refrigerants by ASHRAE safety group and state the practical consequence of each class for working methods
Select appropriate PPE for a given task and explain the limitations of each item, including glove type and eye protection during liquid contact
Complete a five-step risk assessment and a dynamic on-site assessment for a live plant room job
Describe safe cylinder handling, storage, inspection and transport requirements, including valve protection and temperature limits
Identify asphyxiation, flammability, pressure-release, freeze-burn and electrical hazards and specify a control for each
Your checkpoint
Two completed risk assessments - one for an A2L system and one for an A3 system - plus a PPE selection matrix covering five different tasks
Refrigerant safety, cylinder handling, PPE and risk assessment & Leak checking, containment, record keeping and reporting obligations
Work through scenario questions that combine safety decisions with leak-checking and record-keeping duties
Re-test every goal from weeks 1 to 6 and rank the weakest six by mock-question error rate
Practise explaining legal and technical points aloud in the concise style required by written exam answers
Review the error log and rewrite every missed question with the correct reasoning
Your checkpoint
A 60-question mixed bank across all five domains scored at 80% or better, with a dated error log showing each weak area and the action taken
F-gas and ODS regulations, legal duties and environmental impact & Refrigerant safety, cylinder handling, PPE and risk assessment & Leak checking, containment, record keeping and reporting obligations & Installation, commissioning, pressure testing and evacuation of RAC systems & Servicing, maintenance, refrigerant recovery, recycling and decommissioning
Sit two full-length timed mock papers under exam conditions and record the score for each domain
Revisit the three lowest-scoring domain areas and close each gap with targeted revision
Memorise the key numbers - leak-check intervals, CO2e thresholds, test pressures, vacuum limits, cylinder fill limits - and self-test them from memory
Confirm the practical tasks and documentation you can perform confidently, and list anything still needing supervised practice
Your checkpoint
Two completed timed mock papers at 85% or better, with a final one-page revision sheet of key figures and a written list of remaining weak points
Milestones
Week 2: Can state the leak-check interval and post-repair re-check timing for any given charge size and system type without notes, and produce a compliant equipment record unaided
Week 4: Scores 75% or better on a timed 40-question paper covering domains 1, 3 and 4, and can calculate a strength-test pressure and a recovery cylinder fill limit correctly
Week 6: Produces a complete risk assessment in under 20 minutes and correctly assigns the safety group and required controls for six named refrigerants
Week 8: Achieves 85% or better on two full timed mocks with no single domain below 70%, and has no unresolved items on the error log