AMPP S-CAT study materials
AMPP S-CAT study resources

AMPP S-CAT cheat sheet

AMPP S-CAT · Keep the key ideas within reach.

Quick reference

Spray Coating Application

  • Wet film thickness (WFT) = dry film thickness (DFT) ÷ volume solids fraction; a 70% VS coating sprayed to 10 mils DFT needs about 14.3 mils WFT.

  • Theoretical coverage (ft²/gal) = 1604 × volume solids fraction ÷ DFT in mils; multiply by (1 − transfer efficiency) to get practical coverage.

  • Conventional air spray transfer efficiency is typically 25–40%; airless 40–60%; air-assisted airless and HVLP 55–75%; the balance is overspray loss.

  • Airless tip orifice size controls flow: doubling orifice area roughly quadruples flow at constant pressure, since flow rises with the square of orifice diameter.

  • Fluid pressure in airless spraying is set by pump ratio × air motor pressure; a 30:1 pump at 60 psi air delivers about 1800 psi fluid.

  • HVLP is defined by atomizing air pressure at the cap of 10 psi or less, reducing bounce-back and overspray.

  • Pot life starts when components are mixed; a coating with a 4-hour pot life that gels must be discarded, not thinned back into service.

  • Stripe coats are applied first at edges, welds, and back-cut areas to build thickness the broad spray pass cannot reach.

Quick reference

Surface Preparation

  • NACE/SSPC abrasive blast cleanliness grades: SSPC-SP 5 / NACE No. 1 (white metal), SP 10 / NACE No. 2 (near-white), SP 6 / NACE No. 3 (commercial), SP 7 / NACE No. 4 (brush-off).

  • Abrasive blast profile is specified as a range; typical angular grit profiles are 1.5–3.5 mils, and profile depth must fall within the coating maker's stated range.

  • ISO 8501-1 rust grades: A (intact mill scale), B (mill scale beginning to rust), C (mill scale gone, pitting), D (general pitting).

  • Surface preparation to SP 10 permits staining on no more than 5% of each unit area; SP 5 permits no visible residue.

  • Soluble salt contamination is commonly limited to 3 µg/cm² chloride for immersion service and higher for atmospheric exposure; test per ISO 8502-6/9.

  • Ambient conditions for blasting and coating usually require steel temperature at least 3°C (5°F) above dew point and relative humidity below 85%.

  • Anchor profile is measured by replica tape (press-o-film) or a profilometer; coarse-grade tape reads 20–50 µm range, X-coarse 38–115 µm.

  • Power tool cleaning grades: SSPC-SP 3 (power tool), SP 11 (power tool to bare metal), SP 2 and SP 15 for hand tool equivalents.

Quick reference

Safety and Inspection

  • Air-supplied respirators for blast/coat require Grade D breathing air: 19.5–23.5% oxygen, CO below 10 ppm, no oil mist or particulate above limits.

  • Confined space entry requires atmospheric testing for oxygen, flammability, and toxicity before entry and continuous monitoring during work.

  • Coating DFT is measured with magnetic gauges on steel; Type 1 gauges are least accurate, Type 2 better; take multiple readings per area and average.

  • SSPC-PA 2 defines DFT acceptance: each gauge reading must be at least 80% of specified thickness, and the average must meet or exceed specification.

  • Holiday (pinhole) detection uses low-voltage wet sponge for thin films and high-voltage spark testers for thicker films; voltage is set per film thickness.

  • Adhesion is verified by cross-cut or pull-off testing; pull-off results are reported in psi or MPa and compared to the specified minimum.

  • Solvent and coating vapors are flammable; bonding and grounding of equipment and containers prevents static ignition during transfer.

  • Inspection records should capture ambient conditions (temperature, RH, dew point), surface profile, DFT readings, and cure verification for each lot.