Wet film to dry film
WFT = DFT ÷ volume solids fraction. A 65% solids coating needing 8 mils DFT requires about 12.3 mils wet film at application.
Theoretical coverage formula
Coverage in ft²/gal = 1604 × volume solids ÷ DFT (mils). This gives the maximum area one gallon can cover at that thickness.
Transfer efficiency
The fraction of sprayed coating that lands on the target. Airless typically 40–60%, conventional air spray 25–40%, HVLP often above 55%.
Airless tip orifice effect
Flow through an airless tip increases roughly with the square of orifice diameter, so doubling orifice size about quadruples flow at constant pressure.
Pump ratio meaning
Outlet fluid pressure equals pump ratio times inlet air pressure. A 30:1 pump at 60 psi air produces about 1800 psi fluid.
HVLP definition
High-volume low-pressure spraying uses atomizing air at the cap of 10 psi or less, reducing overspray and bounce-back.
Pot life
The working time after mixing multi-component coatings before viscosity rises beyond use. Expired material must be discarded, not thinned back into service.
Stripe coat purpose
A first pass applied by brush or spray at edges, welds, and corners to build thickness the broad spray pass cannot reach.
Spray gun distance
Typical spray distance is 6–12 inches from the surface, held perpendicular, with 50% overlap between passes for uniform film build.
SSPC-SP 5
White metal blast cleaning, NACE No. 1. Removes all visible oil, grease, dirt, mill scale, rust, and coating, leaving a uniform gray-white surface.
SSPC-SP 10
Near-white blast cleaning, NACE No. 2. Allows staining on no more than 5% of each unit area; removes nearly all visible residue.
SSPC-SP 6
Commercial blast cleaning, NACE No. 3. Removes at least two-thirds of visible residue, allowing staining and tight residues on the remainder.
SSPC-SP 7
Brush-off blast cleaning, NACE No. 4. Removes loose mill scale, rust, and coating while leaving tightly adherent material intact.
ISO 8501 rust grades
Rust grades A through D describe initial steel condition: A intact mill scale, B rusting mill scale, C mill scale gone with pitting, D general pitting.
Anchor profile range
The surface roughness produced by blasting, usually 1.5–3.5 mils for grit. It must fall within the coating manufacturer's specified range.
Replica tape measurement
A foam tape pressed against blasted steel captures profile depth, read with a micrometer. Coarse tape covers roughly 20–50 µm.
Soluble salt limit
Chloride contamination is often limited to about 3 µg/cm² for immersion service. Tested by the Bresle patch method per ISO 8502-6/9.
Dew point rule
Steel temperature must be at least 3°C (5°F) above the dew point during blasting and coating to prevent condensation on the surface.
Relative humidity limit
Most coating specifications require relative humidity below 85% during application and cure, unless the product data sheet states otherwise.
Power tool cleaning
SSPC-SP 3 removes loose material with power tools; SSPC-SP 11 removes to bare metal, leaving a roughened surface for coating.
Mill scale removal
Mill scale is a cathodic oxide layer that must be removed because it causes galvanic corrosion and coating disbondment if left under a film.
Grade D breathing air
Supplied air for respirators must contain 19.5–23.5% oxygen, carbon monoxide below 10 ppm, and no oil mist or objectionable particulate.
Confined space testing
Atmospheric testing for oxygen, flammability, and toxicity is required before entry and continuously during work inside tanks and vessels.
SSPC-PA 2 acceptance
Each DFT gauge reading must be at least 80% of the specified thickness, and the average of readings must equal or exceed the specification.
DFT gauge types
Type 1 magnetic gauges are least accurate; Type 2 constant-pressure gauges are more accurate. Multiple readings per area are averaged.
Holiday detection
Low-voltage wet sponge testing finds pinholes in thin films; high-voltage spark testers are used for thicker films with voltage set per thickness.
Pull-off adhesion test
A dolly is bonded to the coating and pulled until failure; results in psi or MPa are compared to the specified minimum adhesion value.
Static ignition control
Bonding and grounding of containers and equipment during solvent transfer prevents static discharge that could ignite flammable vapors.
Cure verification
Solvent rub or MEK test confirms a coating has cured enough for recoating or service, based on the product data sheet method.
Inspection record content
Each lot record should capture ambient temperature, relative humidity, dew point, surface profile, DFT readings, and cure verification results.
Oxygen deficiency
Atmospheres below 19.5% oxygen are immediately dangerous; entry requires supplied air and continuous monitoring, never a filter respirator.
Solvent vapor flammability
Coating solvents form flammable mixtures with air; lower explosive limit values dictate ventilation and gas monitoring requirements before and during work.