ASSE 5130 key terms
ASSE 5130 · Get comfortable with the vocabulary.
- Cross-connection
- Related: Backflow, Air gap
Any actual or potential link between a potable water supply and a source of contamination or pollution, creating a path by which non-potable material could enter the drinking water system.
- Backflow
- Related: Backsiphonage, Backpressure, Cross-connection
The unwanted reverse flow of water, or of other substances, through a piping arrangement into the potable distribution system, caused by backsiphonage or backpressure conditions.
- Backsiphonage
- Related: Backflow, Vacuum breaker
Backflow produced by a negative or reduced pressure in the supply piping, which draws non-potable liquid into the system through a cross-connection, as during a main break or heavy demand.
- Backpressure
- Related: Backflow, Reduced pressure principle assembly
Backflow caused by downstream pressure exceeding the pressure of the potable supply, commonly created by pumps, boilers, elevation differences, or compressed gas pushing fluid backward.
- Pollution
- Related: Contamination, Degree of hazard
A condition that degrades water quality but does not by itself create a health hazard, such as cloudiness, odor, or objectionable taste; a lower degree of hazard than contamination.
- Contamination
- Related: Pollution, Degree of hazard
The introduction of any substance into potable water that creates an actual hazard to public health, such as sewage, toxic chemicals, or disease-causing organisms.
- Degree of hazard
- Related: Contamination, Pollution
The classification of a cross-connection as either high or low based on whether the potential contaminant poses a health risk or only an aesthetic or quality nuisance.
- Air gap
- Related: Flood level rim, Backflow
A physical separation between the free-flowing discharge end of a potable supply pipe and the flood level rim of a receiving vessel, providing the highest protection against backflow.
- Reduced pressure principle assembly
- Related: Check valve, Relief valve
A testable backflow preventer using two independently acting check valves with a hydraulically operated differential relief valve between them, giving high-hazard protection without an air gap.
- Double check valve assembly
- Related: Check valve, Degree of hazard
A testable assembly of two independently acting check valves in series, used to protect against low-hazard, non-health-threatening pollution where backpressure is not severe.
- Pressure vacuum breaker assembly
- Related: Vacuum breaker, Backsiphonage
A testable assembly with a loaded air inlet valve on the discharge side of a check valve, protecting against backsiphonage but not backpressure, and requiring installation above the highest downstream outlet.
- Atmospheric vacuum breaker
- Related: Vacuum breaker, Backsiphonage
A non-testable device with a float or disc that opens to atmosphere when supply pressure drops, preventing backsiphonage; it must be installed above the flood level and cannot be pressurized.
- Spill-resistant vacuum breaker
- Related: Pressure vacuum breaker assembly, Air inlet valve
A vacuum breaker assembly designed to discharge only minimal water from its air inlet during normal operation, allowing installation in areas where spillage would otherwise be a concern.
- Check valve
- Related: Double check valve assembly, Reduced pressure principle assembly
A valve that permits flow in only one direction and closes automatically when flow reverses, forming the core component of most testable backflow prevention assemblies.
- Relief valve
- Related: Reduced pressure principle assembly, Sensing passage
The differential-pressure-operated valve in a reduced pressure principle assembly that opens to discharge water when the pressure between the check valves approaches supply pressure, signaling a fault.
- Air inlet valve
- Related: Vacuum breaker, Spill-resistant vacuum breaker
The opening on a vacuum breaker that admits atmospheric air into the assembly when internal pressure drops, breaking the vacuum that would otherwise cause backsiphonage.
- Flood level rim
- Related: Air gap, Critical level
The edge of the receptacle or fixture from which water overflows, used as the reference point for measuring the required air gap or installation height of a vacuum breaker.
- Critical level
- Related: Flood level rim, Pressure vacuum breaker assembly
The marked elevation on a vacuum breaker or backflow device that must be installed at or above the flood level rim of the fixture served, per the manufacturer's listing.
- Differential pressure
- Related: Relief valve, Check valve
The difference in pressure measured between two points in an assembly, such as across a check valve or across the relief valve seat, used to judge whether the device is holding properly.
- Test cock
- Related: Differential pressure, Test gauge
A small, normally closed valve on a backflow assembly that allows a tester to attach gauges or bleed water to measure pressures at specific points during a field test.
- Sensing passage
- Related: Relief valve, Differential pressure
The internal channel in a reduced pressure principle assembly that delivers supply-side pressure to the relief valve diaphragm, allowing it to react to changes in differential pressure.
- Test gauge
- Related: Test cock, Differential pressure
A calibrated differential pressure gauge, typically with a 0–15 psi range and small graduations, used with hoses and test cocks to verify assembly performance in the field.
- Disc
- Related: Check valve, Seat
The movable sealing element inside a check valve or vacuum breaker that contacts the seat to stop flow; wear, debris, or deformation of the disc is a common cause of test failure.
- Seat
- Related: Disc, Check valve
The machined surface inside a valve against which the disc or clapper seals; nicks, scale, or wear on the seat cause leakage and require cleaning or replacement.
- O-ring
- Related: Bonnet, Seat
A circular elastomeric seal used at joints, stems, and bonnets of backflow assemblies to prevent external leakage; deterioration leads to drips and requires replacement during repair.
- Bonnet
- Related: O-ring, Disc
The removable cover or cap on a valve body that houses the stem and internal parts, allowing access for inspection, cleaning, and replacement of discs and springs.
- Freeze protection
- Related: Drainage, Enclosure
Measures such as insulation, heat tracing, draining, or enclosure that keep a backflow assembly from freezing, since ice damage can crack bodies and ruin internal seals.
- Enclosure
- Related: Freeze protection, Drainage
A cabinet or vault housing a backflow assembly, which must provide drainage, access for testing and repair, and protection from freezing, flooding, and unauthorized tampering.
- Drainage
- Related: Enclosure, Relief valve
The means of removing discharge from relief valves, test cock bleeding, and spills to a safe location, required so assemblies do not flood their enclosures or create hazards.
- Site survey
- Related: Degree of hazard, Cross-connection
A systematic inspection of a property's plumbing and processes to identify cross-connections, classify hazards, and determine the appropriate backflow prevention method for each point of use.
- Containment
- Related: Isolation, Site survey
Protection installed at the service connection or property boundary to isolate the entire premises from the public main, typically required where internal hazards cannot be individually controlled.
- Isolation
- Related: Containment, Air gap
Point-of-use backflow protection installed at an individual fixture, appliance, or process within a building, protecting the internal piping rather than the public supply.
- Annual testing
- Related: Test report, Test gauge
The recurring field verification, usually required at least once a year by the water authority, that a testable backflow assembly meets its specified performance values.
- Test report
- Related: Annual testing, Test gauge
The documented record of an assembly test listing device type, location, serial number, gauge readings, pass or fail result, tester identity, and date, submitted to the authority.
- Device registration
- Related: Test report, Annual testing
The process of recording a backflow assembly with the water purveyor, assigning an identification number and tracking its location, test history, and compliance status.
- Tester certification
- Related: Annual testing, Test report
Formal credentialing, often through a recognized training program and examination, that authorizes an individual to test backflow prevention assemblies within a jurisdiction.
- Personal protective equipment
- Related: Test cock, Drainage
Safety gear such as gloves, eye protection, and footwear worn while testing or repairing assemblies to guard against pressurized water, chemicals, and contaminated discharge.
- Hazard assessment
- Related: Degree of hazard, Site survey
The evaluation of what contaminant or pollutant a cross-connection could introduce and how severe the health effect would be, guiding selection of the proper protection level.