FPAS Fire Systems Design (FSD) study materials
FPAS Fire Systems Design (FSD) study resources

FPAS Fire Systems Design (FSD) key terms

FPAS Fire Systems Design (FSD) · Get comfortable with the vocabulary.

Addressable fire alarm system

A detection system in which each detector or module has a unique address, letting the control panel identify the exact device in alarm or fault.

Related: Conventional fire alarm system, Fire alarm control panel, Notification appliance
Conventional fire alarm system

A detection system that groups devices into circuits or zones, so the panel reports only the zone containing an alarm rather than the individual device.

Related: Addressable fire alarm system, Fire alarm control panel
Photoelectric smoke detector

A detector that uses a light source and sensor to detect smoke particles scattering light inside a chamber, typically responding faster to visible smoke.

Related: Heat detector, Alarm verification
Heat detector

A device that responds to an abnormal rise in temperature or to a fixed high temperature, using a heat-sensitive element rather than smoke sensing.

Related: Photoelectric smoke detector, Manual call point
Manual call point

A manually operated device, usually wall-mounted, that lets a person trigger a fire alarm by breaking glass or pushing a frangible element.

Related: Fire alarm control panel, Notification appliance
Fire alarm control panel

The central unit that receives signals from detection devices, monitors circuits, activates notification appliances, and displays alarm, fault, and supervisory conditions.

Related: Addressable fire alarm system, Notification appliance, Alarm verification
Alarm verification

A feature that briefly delays alarm reporting from a detector to check for a continuing signal, reducing nuisance alarms from transient smoke or dust.

Related: Photoelectric smoke detector, Fire alarm control panel
Notification appliance

An audible or visual device such as a sounder, bell, horn, or strobe that warns occupants of a fire alarm condition.

Related: Fire alarm control panel, Manual call point
Sprinkler head

A heat-activated device that opens at a rated temperature to discharge water in a designed spray pattern and, in most types, operate an alarm.

Related: Quick-response sprinkler, K-factor, Wet pipe sprinkler system
Quick-response sprinkler

A sprinkler with a fast thermal element, identified by a low response time index, intended to operate sooner and limit fire growth.

Related: Sprinkler head, Design density
K-factor

A numerical coefficient relating sprinkler discharge flow to the square root of nozzle pressure, used to select orifice size and calculate flow.

Related: Sprinkler head, Design density, Remote area
Design density

The minimum water application rate, usually expressed in millimeters per minute over a stated area, that a sprinkler design must achieve.

Related: Remote area, Sprinkler head, K-factor
Remote area

The hydraulically most demanding area of sprinkler operation used in calculations, defined by shape and size for the hazard being protected.

Related: Design density, Sprinkler head
Wet pipe sprinkler system

A sprinkler system with pipes kept full of pressurized water, so a sprinkler opening discharges water immediately and activates the alarm.

Related: Dry pipe sprinkler system, Pre-action sprinkler system, Flow switch
Dry pipe sprinkler system

A sprinkler system with pipes filled with compressed air or nitrogen; opening a sprinkler releases the gas, allowing water to enter and flow.

Related: Wet pipe sprinkler system, Pre-action sprinkler system
Pre-action sprinkler system

A sprinkler system that requires a fire detection signal to admit water into the piping before sprinkler operation, reducing accidental discharge risk.

Related: Wet pipe sprinkler system, Dry pipe sprinkler system, Deluge system
Deluge system

A sprinkler system with open heads and a deluge valve that releases water to all nozzles at once when detection or manual release activates.

Related: Pre-action sprinkler system, Sprinkler head
Flow switch

A device that senses water movement in a sprinkler pipe and sends an alarm or supervisory signal to the fire alarm panel.

Related: Wet pipe sprinkler system, Fire alarm control panel
Fire hydrant

A valved connection on a water main, typically outdoors, that supplies water to firefighting hose or pumpers through one or more outlets.

Related: Fire main, Flow test, Landing valve
Hose reel

A fixed assembly of small-diameter fire hose wound on a reel, connected to a water supply and intended for first-aid firefighting by occupants.

Related: Fire main, Landing valve
Landing valve

A valve installed on a vertical fire main, usually in a stairwell or landing, providing a controlled outlet for firefighting hose.

Related: Fire main, Fire hydrant, Hose reel
Fire main

A pipe network that distributes water from a supply source to hydrants, landing valves, hose reels, or sprinkler systems.

Related: Fire hydrant, Landing valve, Hose reel
Static pressure

The water pressure measured at a point when no water is flowing, representing the stored or elevation-derived pressure available in the system.

Related: Residual pressure, Flow test
Residual pressure

The pressure remaining at a point while water is flowing, showing the pressure available after friction losses in the supply.

Related: Static pressure, Flow test
Flow test

A test that measures static pressure, residual pressure, and flow rate at a hydrant or outlet to estimate available water supply for firefighting.

Related: Static pressure, Residual pressure, Fire hydrant
Clean agent

A volatile fire suppressant that leaves little or no residue after discharge and is safe for occupied spaces when used at its design concentration.

Related: Design concentration, Hold time, Room integrity test
Design concentration

The suppressant concentration, usually a percentage by volume, that must be maintained in the protected space to extinguish or inert a specific hazard.

Related: Clean agent, Hold time
Hold time

The period for which a gaseous agent concentration must remain above the design concentration in a room after discharge, allowing safe egress.

Related: Design concentration, Room integrity test
Room integrity test

A door-fan test that measures air leakage in an enclosure to predict whether it can retain a gaseous agent for the required hold time.

Related: Hold time, Clean agent
Predischarge alarm

An audible and visual warning activated automatically before a gaseous system discharges, alerting occupants to leave the protected space immediately.

Related: CO2 suppression system, Kitchen hood suppression system
CO2 suppression system

A system using carbon dioxide as the extinguishing agent, suitable for unoccupied or normally unoccupied spaces because of its asphyxiation risk.

Related: Predischarge alarm, Design concentration
Kitchen hood suppression system

A pre-engineered system that automatically discharges wet chemical onto cooking appliances, filters, and hood plenums to extinguish cooking-oil and deep-fat fires.

Related: Wet chemical extinguisher, Predischarge alarm
Portable fire extinguisher

A hand-carried or wheeled unit containing an extinguishing agent and manual discharge mechanism, intended for immediate use on small fires.

Related: Fire extinguisher rating, PASS technique, Extinguisher travel distance
Fire extinguisher rating

A classification showing which fire classes an extinguisher can safely tackle, such as Class A, B, C, D, or K.

Related: ABC dry chemical extinguisher, CO2 extinguisher, Wet chemical extinguisher
ABC dry chemical extinguisher

A pressurized multipurpose extinguisher typically containing ammonium phosphate powder, effective on ordinary combustibles, flammable liquids, and energized electrical equipment fires.

Related: Fire extinguisher rating, Portable fire extinguisher
CO2 extinguisher

A stored-pressure unit that discharges carbon dioxide gas, mainly for flammable liquid and electrical fires, leaving no residue but providing limited cooling.

Related: Fire extinguisher rating, Portable fire extinguisher
Wet chemical extinguisher

An extinguisher containing an alkaline solution that reacts with cooking oils to form a soapy layer, intended for Class K kitchen fires.

Related: Fire extinguisher rating, Kitchen hood suppression system
Hydrostatic test

A pressure test in which an extinguisher cylinder or hose is filled with water and subjected to a specified pressure to prove structural strength.

Related: Portable fire extinguisher, CO2 extinguisher
PASS technique

A user technique for extinguishers: pull the pin, aim at the base of the fire, squeeze the lever, and sweep the nozzle across the fire.

Related: Portable fire extinguisher, Fire extinguisher rating
Extinguisher travel distance

The maximum distance a person should have to travel from a point in a space to reach a suitable portable extinguisher, set by occupancy hazard.

Related: Portable fire extinguisher, Fire extinguisher rating