FPAS Fire Systems Design (FSD) key terms
FPAS Fire Systems Design (FSD) · Get comfortable with the vocabulary.
- Addressable fire alarm system
- Related: Conventional fire alarm system, Fire alarm control panel, Notification appliance
A detection system in which each detector or module has a unique address, letting the control panel identify the exact device in alarm or fault.
- Conventional fire alarm system
- Related: Addressable fire alarm system, Fire alarm control panel
A detection system that groups devices into circuits or zones, so the panel reports only the zone containing an alarm rather than the individual device.
- Photoelectric smoke detector
- Related: Heat detector, Alarm verification
A detector that uses a light source and sensor to detect smoke particles scattering light inside a chamber, typically responding faster to visible smoke.
- Heat detector
- Related: Photoelectric smoke detector, Manual call point
A device that responds to an abnormal rise in temperature or to a fixed high temperature, using a heat-sensitive element rather than smoke sensing.
- Manual call point
- Related: Fire alarm control panel, Notification appliance
A manually operated device, usually wall-mounted, that lets a person trigger a fire alarm by breaking glass or pushing a frangible element.
- Fire alarm control panel
- Related: Addressable fire alarm system, Notification appliance, Alarm verification
The central unit that receives signals from detection devices, monitors circuits, activates notification appliances, and displays alarm, fault, and supervisory conditions.
- Alarm verification
- Related: Photoelectric smoke detector, Fire alarm control panel
A feature that briefly delays alarm reporting from a detector to check for a continuing signal, reducing nuisance alarms from transient smoke or dust.
- Notification appliance
- Related: Fire alarm control panel, Manual call point
An audible or visual device such as a sounder, bell, horn, or strobe that warns occupants of a fire alarm condition.
- Sprinkler head
- Related: Quick-response sprinkler, K-factor, Wet pipe sprinkler system
A heat-activated device that opens at a rated temperature to discharge water in a designed spray pattern and, in most types, operate an alarm.
- Quick-response sprinkler
- Related: Sprinkler head, Design density
A sprinkler with a fast thermal element, identified by a low response time index, intended to operate sooner and limit fire growth.
- K-factor
- Related: Sprinkler head, Design density, Remote area
A numerical coefficient relating sprinkler discharge flow to the square root of nozzle pressure, used to select orifice size and calculate flow.
- Design density
- Related: Remote area, Sprinkler head, K-factor
The minimum water application rate, usually expressed in millimeters per minute over a stated area, that a sprinkler design must achieve.
- Remote area
- Related: Design density, Sprinkler head
The hydraulically most demanding area of sprinkler operation used in calculations, defined by shape and size for the hazard being protected.
- Wet pipe sprinkler system
- Related: Dry pipe sprinkler system, Pre-action sprinkler system, Flow switch
A sprinkler system with pipes kept full of pressurized water, so a sprinkler opening discharges water immediately and activates the alarm.
- Dry pipe sprinkler system
- Related: Wet pipe sprinkler system, Pre-action sprinkler system
A sprinkler system with pipes filled with compressed air or nitrogen; opening a sprinkler releases the gas, allowing water to enter and flow.
- Pre-action sprinkler system
- Related: Wet pipe sprinkler system, Dry pipe sprinkler system, Deluge system
A sprinkler system that requires a fire detection signal to admit water into the piping before sprinkler operation, reducing accidental discharge risk.
- Deluge system
- Related: Pre-action sprinkler system, Sprinkler head
A sprinkler system with open heads and a deluge valve that releases water to all nozzles at once when detection or manual release activates.
- Flow switch
- Related: Wet pipe sprinkler system, Fire alarm control panel
A device that senses water movement in a sprinkler pipe and sends an alarm or supervisory signal to the fire alarm panel.
- Fire hydrant
- Related: Fire main, Flow test, Landing valve
A valved connection on a water main, typically outdoors, that supplies water to firefighting hose or pumpers through one or more outlets.
- Hose reel
- Related: Fire main, Landing valve
A fixed assembly of small-diameter fire hose wound on a reel, connected to a water supply and intended for first-aid firefighting by occupants.
- Landing valve
- Related: Fire main, Fire hydrant, Hose reel
A valve installed on a vertical fire main, usually in a stairwell or landing, providing a controlled outlet for firefighting hose.
- Fire main
- Related: Fire hydrant, Landing valve, Hose reel
A pipe network that distributes water from a supply source to hydrants, landing valves, hose reels, or sprinkler systems.
- Static pressure
- Related: Residual pressure, Flow test
The water pressure measured at a point when no water is flowing, representing the stored or elevation-derived pressure available in the system.
- Residual pressure
- Related: Static pressure, Flow test
The pressure remaining at a point while water is flowing, showing the pressure available after friction losses in the supply.
- Flow test
- Related: Static pressure, Residual pressure, Fire hydrant
A test that measures static pressure, residual pressure, and flow rate at a hydrant or outlet to estimate available water supply for firefighting.
- Clean agent
- Related: Design concentration, Hold time, Room integrity test
A volatile fire suppressant that leaves little or no residue after discharge and is safe for occupied spaces when used at its design concentration.
- Design concentration
- Related: Clean agent, Hold time
The suppressant concentration, usually a percentage by volume, that must be maintained in the protected space to extinguish or inert a specific hazard.
- Hold time
- Related: Design concentration, Room integrity test
The period for which a gaseous agent concentration must remain above the design concentration in a room after discharge, allowing safe egress.
- Room integrity test
- Related: Hold time, Clean agent
A door-fan test that measures air leakage in an enclosure to predict whether it can retain a gaseous agent for the required hold time.
- Predischarge alarm
- Related: CO2 suppression system, Kitchen hood suppression system
An audible and visual warning activated automatically before a gaseous system discharges, alerting occupants to leave the protected space immediately.
- CO2 suppression system
- Related: Predischarge alarm, Design concentration
A system using carbon dioxide as the extinguishing agent, suitable for unoccupied or normally unoccupied spaces because of its asphyxiation risk.
- Kitchen hood suppression system
- Related: Wet chemical extinguisher, Predischarge alarm
A pre-engineered system that automatically discharges wet chemical onto cooking appliances, filters, and hood plenums to extinguish cooking-oil and deep-fat fires.
- Portable fire extinguisher
- Related: Fire extinguisher rating, PASS technique, Extinguisher travel distance
A hand-carried or wheeled unit containing an extinguishing agent and manual discharge mechanism, intended for immediate use on small fires.
- Fire extinguisher rating
- Related: ABC dry chemical extinguisher, CO2 extinguisher, Wet chemical extinguisher
A classification showing which fire classes an extinguisher can safely tackle, such as Class A, B, C, D, or K.
- ABC dry chemical extinguisher
- Related: Fire extinguisher rating, Portable fire extinguisher
A pressurized multipurpose extinguisher typically containing ammonium phosphate powder, effective on ordinary combustibles, flammable liquids, and energized electrical equipment fires.
- CO2 extinguisher
- Related: Fire extinguisher rating, Portable fire extinguisher
A stored-pressure unit that discharges carbon dioxide gas, mainly for flammable liquid and electrical fires, leaving no residue but providing limited cooling.
- Wet chemical extinguisher
- Related: Fire extinguisher rating, Kitchen hood suppression system
An extinguisher containing an alkaline solution that reacts with cooking oils to form a soapy layer, intended for Class K kitchen fires.
- Hydrostatic test
- Related: Portable fire extinguisher, CO2 extinguisher
A pressure test in which an extinguisher cylinder or hose is filled with water and subjected to a specified pressure to prove structural strength.
- PASS technique
- Related: Portable fire extinguisher, Fire extinguisher rating
A user technique for extinguishers: pull the pin, aim at the base of the fire, squeeze the lever, and sweep the nozzle across the fire.
- Extinguisher travel distance
- Related: Portable fire extinguisher, Fire extinguisher rating
The maximum distance a person should have to travel from a point in a space to reach a suitable portable extinguisher, set by occupancy hazard.