Mistake 1

Applying the full AS/NZS 3500 sanitary plumbing and drainage sizing and grade rules to a small domestic job without first confirming which code and local water authority requirements actually govern the site.

Candidates memorise one national standard and assume it overrides state variations, sewer authority requirements and manufacturer instructions, so they misapply grade, venting and sizing values on scenario questions.

What to do instead

Before answering any sizing or grading question, identify the jurisdiction and check the hierarchy: Act and Regulation, then adopted standards, then local authority requirements, then manufacturer instructions. Practise scenario questions where a state variation changes the answer.

Mistake 2

Selecting a trap or fixture with the wrong trap seal depth or setting an untrapped or incorrectly vented fixture, such as a fixture discharging through an unvented branch.

Candidates confuse minimum and maximum seal depths and forget that trap seal retention depends on venting, so they pick a plausible-looking fixture rather than verifying seal depth, vent distance and wet-vented rules.

What to do instead

Memorise the trap seal minimum and maximum values and the vent distance limits, then for each practice question write out the seal depth, the vent provision and the fixture classification before choosing an answer.

Mistake 3

Using the wrong pipe material or jointing method for the application, for example solvent cement on a material that requires mechanical jointing, or mixing incompatible materials without a transition fitting.

Candidates learn jointing methods as a list rather than as a match to material, pressure class and application, and exam distractors deliberately pair a familiar method with the wrong material.

What to do instead

Build a material-to-joint matrix covering PVC, copper, PEX, poly and cast iron, including approved transition methods and pressure ratings. For each question, name the material and the approved joint before evaluating the options.

Mistake 4

Treating drainage and gasfitting as separate knowledge sets and missing overlap items, such as gas pipework passing through a drainage penetration, sleeve requirements, or clearances from sanitary fixtures.

Candidates study by domain and never rehearse cross-domain scenarios, so they miss questions that test clearances, protection of gas services from corrosion, and separation from drainage and water services.

What to do instead

Create a clearance and separation table covering gas pipework to drainage, water services, electrical fittings and openings, and run mixed practice sets that deliberately combine drainage and gas items.

Mistake 5

Sizing gas pipework from a single appliance load without applying diversity, pressure drop limits or the correct equivalent length for fittings.

Candidates use a pipe size remembered from a similar job instead of calculating, and they forget that bends, tees and valves add equivalent length that reduces available capacity.

What to do instead

Practise full sizing calculations end to end: total load, allowable pressure drop, equivalent length including fittings, then table lookup and verification. Show every step in working notes so the method is repeatable under exam time pressure.

Mistake 6

Installing or testing gas pipework without correct pressure test procedure, including wrong test medium, wrong test pressure or duration, or failing to account for temperature effects.

Candidates remember that a test is required but not the specific pressure, duration and medium conditions, and they confuse commissioning purging requirements with strength testing.

What to do instead

Write out the test sequence from installation through purge and commissioning, with test pressures, hold times and acceptable leakage criteria. Rehearse the sequence aloud until the order and values are automatic.

Mistake 7

Choosing roof drainage components by nominal pipe size alone without checking the design rainfall intensity, catchment area and gutter capacity.

Candidates treat roof plumbing as simple pipe selection and skip the rainfall intensity and catchment calculation, so they under-size gutters, downpipes and overflow provisions.

What to do instead

Work through catchment area multiplied by design rainfall intensity to get flow, then match to gutter and downpipe capacity tables including overflow and surcharge provisions. Do at least one full calculation per study session.

Mistake 8

Omitting or misplacing overflow, expansion and flashing details on roof plumbing answers, such as no overflow relief or incorrect flashing lap direction.

Candidates focus on the primary drainage path and forget secondary provisions, and they get lap direction wrong because they do not visualise water flow direction.

What to do instead

For every roof plumbing scenario, list primary drainage, overflow provision, expansion allowance and flashing sequence in that order. Sketch the water path and confirm each lap sheds water outward and downward.

Mistake 9

Confusing the roles and responsibilities in medical gas and mechanical services, such as who may verify, who may commission, and what documentation is required before a system is handed over.

Candidates learn the physical installation requirements well but skim the governance layer of qualifications, verification and certification, so they pick the wrong person or the wrong document.

What to do instead

Build a responsibility chart mapping each task to the required qualification, the verification step and the record produced. Test yourself by asking who signs what and in what order before handover.

Mistake 10

Disconnecting or reconnecting fixed electrical equipment without confirming isolation, testing for dead, and verifying that the person holds the correct authorisation for the work.

Candidates assume plumbing licences cover the electrical work associated with appliances, and they skip the test-before-touch step because it feels routine rather than critical.

What to do instead

Memorise the boundary of authorised electrical work for plumbers, then rehearse the isolation sequence: identify, isolate, lock out, test for dead, and only then disconnect. Apply the same sequence to every practice scenario involving an appliance.