AZ HVAC · Get comfortable with the vocabulary.
- Registrar of Contractors (ROC)
- Related: Contractor license classification, License bond
The Arizona state agency that issues contractor licenses, investigates complaints about contractors, and enforces the statutes and rules that govern construction work performed in the state.
- Contractor license classification
- Related: Registrar of Contractors (ROC), License bond
A category granted by the Arizona Registrar of Contractors that defines the type of work and dollar limits a contractor may perform, such as residential, commercial, or specialty work.
- License bond
- Related: Registrar of Contractors (ROC), Contractor license classification
A surety bond an Arizona licensed contractor must keep in force as a condition of licensure; it provides a fund from which a consumer may recover for certain violations.
- Preliminary 20-day notice
- Related: Mechanics' lien, Retainage
A written notice that an Arizona subcontractor, laborer, or supplier may serve on the owner and lender early in a project to preserve the right to later record a mechanics' lien.
- Mechanics' lien
- Related: Preliminary 20-day notice, Retainage
A statutory claim recorded against real property by someone who furnished labor, materials, or services for improvements, giving security for payment if the owner or general contractor fails to pay.
- Change order
- Related: Retainage, Preliminary 20-day notice
A written modification to a signed contract that changes scope, schedule, or price; it must be approved by the owner before the extra work is performed to be billable.
- Retainage
- Related: Change order, Mechanics' lien
A percentage of each progress payment withheld by the owner until the work is substantially complete, held to protect against unfinished or defective work.
- Superheat
- Related: Subcooling, Saturation temperature, Thermostatic expansion valve (TXV)
The number of degrees a refrigerant vapor is above its saturation temperature at the measured pressure. Measured at the evaporator outlet, it shows whether the coil is fully boiling liquid refrigerant.
- Subcooling
- Related: Superheat, Saturation temperature, Condenser coil
The number of degrees a liquid refrigerant is below its saturation temperature at the measured pressure. Measured at the condenser outlet, it indicates how much solid liquid seal the condenser is holding.
- Saturation temperature
- Related: Superheat, Subcooling
The temperature at which a refrigerant boils or condenses at a given pressure. Technicians read it from a pressure-temperature chart and compare it with measured line temperatures.
- Latent heat
- Related: Sensible heat, Ton of refrigeration, Evaporator coil
Heat energy absorbed or released when a substance changes phase without changing temperature, such as when liquid refrigerant boils into vapor inside the evaporator coil.
- Sensible heat
- Related: Latent heat, Ton of refrigeration
Heat added to or removed from a substance that causes a measurable temperature change without a change of phase, such as air being warmed or cooled as it crosses a coil.
- Ton of refrigeration
- Related: Latent heat, Sensible heat, Manual J
A cooling rate equal to 12,000 British thermal units per hour, about the heat needed to melt one ton of ice in a day; the standard unit for stating equipment capacity.
- Thermostatic expansion valve (TXV)
- Related: Superheat, Evaporator coil
A metering device that controls refrigerant flow into the evaporator to hold a set superheat, moving its valve in response to bulb pressure, evaporator pressure, and spring force.
- Evaporator coil
- Related: Condenser coil, Thermostatic expansion valve (TXV), Superheat
The indoor heat exchanger where low-pressure liquid refrigerant absorbs heat from the air stream and boils into vapor, cooling and dehumidifying the air that passes over its fins.
- Condenser coil
- Related: Evaporator coil, Subcooling
The heat exchanger where hot, high-pressure refrigerant vapor gives up heat to outdoor air and condenses into liquid, leaving the coil as a subcooled liquid.
- Refrigerant glide
- Related: Zeotropic blend, Superheat
The difference between the bubble point and dew point temperatures of a zeotropic blend at a given pressure, which shifts superheat and subcooling readings during charging.
- Zeotropic blend
- Related: Refrigerant glide, Refrigerant recovery
A refrigerant made of two or more components with different boiling points, so it evaporates and condenses over a temperature range and must be charged as a liquid to avoid fractionation.
- Refrigerant recovery
- Related: EPA Section 608 certification, Zeotropic blend
Removing refrigerant from a system into a recovery cylinder so it can be recycled, reclaimed, or destroyed, required before opening a system or disposing of equipment.
- EPA Section 608 certification
- Related: Refrigerant recovery
A federal credential required for technicians who service, repair, or dispose of equipment containing regulated refrigerants; it certifies knowledge of recovery, handling, and safe practices.
- AFUE
- Related: HSPF2, SEER2
Annual Fuel Utilization Efficiency, the percentage of fuel energy converted to useful heat over a heating season; a higher number means a more efficient furnace or boiler.
- SEER2
- Related: HSPF2, AFUE
Seasonal Energy Efficiency Ratio, the Department of Energy rating for cooling efficiency of air conditioners and heat pumps, calculated under updated test conditions that include blower and duct static pressure.
- HSPF2
- Related: SEER2, Reversing valve
Heating Seasonal Performance Factor, the Department of Energy rating for heat pump heating efficiency over a season, expressed as BTUs of heat delivered per watt-hour of electricity used.
- Reversing valve
- Related: Air handler, Condenser coil
A four-way valve in heat pumps that changes the direction of refrigerant flow so the indoor coil acts as the condenser in heating and as the evaporator in cooling.
- Air handler
- Related: Evaporator coil, External static pressure, Manual D
The indoor cabinet that holds the blower, filter, and often the evaporator coil and electric heat strips, and moves conditioned air into the duct system.
- Ohm's law
- Related: Contactor, Low-voltage thermostat
The relationship in which voltage equals current multiplied by resistance (E = I x R), used to predict amps, check voltage drop, and diagnose motor and control circuits.
- Contactor
- Related: Low-voltage thermostat, Ohm's law
An electrically operated switch whose low-voltage coil pulls in high-voltage contacts, starting and stopping compressors, fan motors, or electric resistance heaters.
- Low-voltage thermostat
- Related: Contactor
A control device that runs on 24 volts, senses room temperature, and closes circuits to call for heating, cooling, or fan operation to hold a selected setpoint.
- External static pressure
- Related: Air balancing, Manual D, Equivalent length
The resistance to airflow measured in inches of water column at the blower outlet and inlet, compared with the fan performance table to confirm the system is moving design airflow.
- Equivalent length
- Related: Manual D, External static pressure
The resistance of a duct fitting expressed as a length of straight duct, added to the actual run length so friction loss can be estimated for the entire path.
- Manual D
- Related: Equivalent length, External static pressure, Air balancing
ACCA's residential duct design procedure that sizes ducts from room airflows, available static pressure, and a selected friction rate for each run.
- Air balancing
- Related: External static pressure, Manual D
Adjusting dampers, registers, and blower speed so each room receives its design airflow, verified with a flow hood or pressure readings.
- Brazing
- Related: Nitrogen purge, Flare fitting
Joining tubing by heating the joint above roughly 840 degrees Fahrenheit so a filler alloy melts and flows into the gap by capillary action; stronger than soldering and used on refrigerant lines.
- Nitrogen purge
- Related: Brazing
Flowing dry nitrogen through piping while brazing to push out oxygen and prevent internal oxidation, which would otherwise form scale that contaminates valves and filters.
- Flare fitting
- Related: Brazing
A mechanical joint made by compressing a flared tubing end against a fitting with a nut, used where brazing is impractical, such as at some service valves and mini-split connections.
- Manual J
- Related: Design temperature, Ton of refrigeration
ACCA's residential load calculation method that estimates heating and cooling loads from construction details, windows, occupancy, and local design conditions.
- Design temperature
- Related: Manual J, Ton of refrigeration
The outdoor and indoor conditions selected for sizing equipment, usually a local winter and summer temperature paired with a target indoor comfort level.
- Personal protective equipment (PPE)
- Related: Fall protection, Lockout/tagout
Gloves, eye and face protection, respirators, and other gear worn to protect a worker from injury, burns, refrigerant exposure, and airborne hazards on the job.
- Fall protection
- Related: Personal protective equipment (PPE)
Guardrails, harnesses, lanyards, and anchor points used to prevent or arrest a fall when working at heights where a fall could cause serious injury.
- Lockout/tagout
- Related: Personal protective equipment (PPE), Contactor
A procedure for de-energizing equipment, applying a personal lock and tag, and verifying zero energy so the unit cannot start while service work is being done.