BiH Engineering & Architecture Licensure Exam cheat sheet
BiH Engineering & Architecture Licensure Exam · Keep the key ideas within reach.
Professional Ethics, Legal Framework, and Practice Regulation
Licensed practice in Bosnia and Herzegovina is regulated by entity-level laws: the Law on Spatial Planning and Construction (FBiH), the Law on Construction and Physical Planning (RS), and cantonal implementing acts; the Brčko District has its own construction law.
Engineers and architects are enrolled in entity chambers (Chamber of Engineers/Chamber of Architects); practicing without a licence or beyond the licensed scope is a misdemeanour subject to fines and possible ban.
Continuing professional development (CPD) is a condition for licence renewal, typically requiring a set number of credit hours per year verified by the chamber.
Core ethical duties: competence within one's field, truthfulness of documentation, avoidance of conflicts of interest, confidentiality of client data, and refusal to certify work one has not verified.
Conflict of interest rule: a designer or supervisor may not certify, review, or approve work in which they or a close associate has a financial interest.
Professional liability: designers and supervisors bear liability for defects caused by their error; liability insurance is required or strongly recommended for practice and for public procurement participation.
Signing and stamping drawings, calculations, and supervision reports is a personal act; the licence holder is accountable for content and may not delegate the signature.
Public procurement of design and supervision services follows the BiH Law on Public Procurement; abnormally low fees that compromise safety are an ethics violation even where legally permitted.
Structural Analysis and Design
Eurocode basis: design value of resistance R_d = R_k/γ_M and design effect E_d = γ_F·E_k; partial factors for persistent actions are typically γ_G = 1.35 and γ_Q = 1.50.
Ultimate limit state check: E_d ≤ R_d; serviceability check: E_d,ser ≤ C_d (deflection, crack width, vibration limits per Eurocode 2/3/5).
Equilibrium and static determinacy: a plane structure is statically determinate when 3 reactions ≥ 3 and internal releases balance; degree of indeterminacy = (3m + r) − (3j + releases).
Superposition applies only to linear elastic systems; second-order (P-Δ) effects must be included when the elastic critical load factor α_cr < 10 (or per national annex).
Concrete: f_cd = α_cc·f_ck/γ_C with γ_C ≈ 1.5; f_ctm from f_ck; minimum reinforcement A_s,min = max(0.26·f_ctm/f_yk, 0.0013)·b·d.
Steel: cross-section resistance uses f_y/γ_M0; member buckling uses χ from the relevant buckling curve and N_b,Rd = χ·A·f_y/γ_M1.
Seismic design: base shear per Eurocode 8, F_b = S_d(T1)·m·λ; behaviour factor q reduces elastic forces; capacity design enforces ductile hierarchy of failure.
Load combinations: persistent/transient use ψ factors for accompanying variable actions; accidental and seismic combinations use ψ2 and reduced partial factors.
Geotechnical Engineering and Foundations
Bearing capacity (drained): q_ult = c'·N_c + q'·N_q + 0.5·γ'·B·N_γ; undrained clay uses q_ult = c_u·N_c + q with N_c ≈ 5.14 for strip footings.
Allowable bearing pressure = q_ult/FS with FS typically 2.5–3.0 for shallow foundations; settlement must also be checked against serviceability limits.
Terzaghi one-dimensional consolidation: S = C_c/(1+e_0)·H·log10((σ'_0+Δσ)/σ'_0) for normally consolidated clay.
Effective stress principle: σ' = σ − u; all strength and stiffness parameters (c', φ', E') are expressed in effective terms for drained conditions.
Liquefaction screening: saturated loose sands below the water table with (N1)60 < 15–20 and groundwater shallower than about 10 m are potentially liquefiable under strong shaking.
Pile capacity: Q_ult = Q_b + Q_s = q_b·A_b + Σ f_s·A_s; group effects reduce capacity and increase settlement relative to single piles.
Earth pressure: Rankine active K_a = tan²(45° − φ/2), passive K_p = tan²(45° + φ/2); at-rest K_0 ≈ 1 − sin φ for normally consolidated soil.
Slope stability: factor of safety F = resisting shear / driving shear; Bishop simplified method is standard for circular slip surfaces, with F ≥ 1.3–1.5 depending on consequence.
Construction Materials, Testing, and Quality Control
Concrete conformity: cube strength f_ck,cyl ≈ 0.8·f_ck,cube; conformity assessed on groups of results per EN 206 with characteristic strength and minimum individual values.
Slump/flow tests assess workability; air content, density, and temperature are routine fresh-concrete checks; specimens cure 28 days at 20 ± 2 °C before compressive testing.
Rebar testing: tensile test gives yield strength R_eH, tensile strength R_m, and elongation A; characteristic values must meet the declared class (e.g., B500B).
Steel structures: welds are checked by visual, ultrasonic, or radiographic methods; bolted connections by torque or tension calibration per the specified class.
Soil compaction control: Proctor (standard or modified) determines maximum dry density and optimum moisture; field density by sand-replacement or nuclear gauge; acceptance requires ≥ 95–98 % of Proctor maximum.
Aggregate tests: grading curve, fineness modulus, Los Angeles abrasion, and flakiness index; alkali–silica reactivity screening for reactive aggregates.
Bituminous mixtures: Marshall stability and flow, air voids, and binder content; compaction degree checked by core density against reference density.
Non-destructive testing: rebound hammer and ultrasonic pulse velocity give indicative strength; cores are required for arbitration or where NDT results are doubtful.
Building Physics, Services, and Energy Efficiency
Thermal transmittance U = 1/R_total; R = d/λ per layer plus surface resistances; lower U means better insulation, and national energy rules set maximum U-values per element.
Thermal bridging: linear thermal transmittance ψ adds to transmission loss; Ψ·l must be included in the envelope heat-loss calculation.
Moisture: Glaser method checks interstitial condensation by comparing vapour pressure to saturation pressure through the assembly; a continuous vapour barrier is placed on the warm side.
Ventilation heat loss Q_v = ρ·c_p·V̇·ΔT; required fresh-air rate follows occupancy and hygiene standards, with heat recovery reducing the loss.
Heating load: transmission plus ventilation losses minus internal and solar gains; boiler and distribution efficiency reduce the delivered energy requirement.
Energy performance certificate (EPC) rates the building from A to G based on primary energy and CO2; nearly zero-energy building (nZEB) targets apply to new construction.
Acoustic insulation: airborne sound reduction index R_w and impact sound level L_n,w; flanking transmission often governs and must be checked separately.
Daylight and lighting: daylight factor = interior illuminance / unobstructed horizontal exterior illuminance × 100; minimum values depend on room use.
Architectural Design, Planning, and Urbanism
Spatial plan hierarchy in BiH: state-level, entity spatial plan, cantonal/regional plan, municipal spatial plan, and urbanistic plan (regulacioni plan) with detailed building rules.
Building rules: buildable area, building line, setback from plot boundaries, height and floor-area ratio (FAR = gross floor area / plot area), and coefficient of built-up area (footprint / plot area).
Accessibility: ramps at ≤ 1:20 slope (1:12 for short runs), minimum clear widths, tactile guidance, and accessible sanitary facilities are mandatory for public buildings.
Fire and life safety in layout: maximum travel distance to an exit, exit width per occupant, compartment size limits, and smoke-ventilated stairs must be checked at concept stage.
Urban mobility: street cross-sections allocate carriageway, parking, sidewalks, and green strips; parking norms per use (e.g., spaces per dwelling or per 100 m² of office) are set locally.
Heritage protection: buildings in protected zones or on the register require conservation approval; interventions must preserve authentic fabric and character.
Solar orientation and microclimate: principal glazing within about 30° of south, shading for summer overheating, and wind protection at entrances.
Public participation: draft spatial and urban plans are subject to public review before adoption; objections must be addressed in the plan documentation.
Construction Technology, Organization, and Management
Critical path method: total float = LS − ES = LF − EF; activities with zero total float form the critical path and drive project duration.
Earned value: CPI = EV/AC, SPI = EV/PV; CPI < 1 means cost overrun, SPI < 1 means schedule slippage.
Concrete construction sequence: formwork, reinforcement, placing, compaction, curing; striking time depends on strength gain and member type.
Earthworks: cut-and-fill balance minimizes haul; compaction in layers of 20–30 cm with moisture control near optimum.
Site layout: crane coverage, material storage, access roads, and temporary facilities must respect safety distances and not obstruct fire access.
Quality plan: inspection and test plan (ITP) defines hold points, witness points, and records for each activity; non-conformities are logged and closed before handover.
Contract types: lump-sum, unit-price (measured), and cost-plus; unit-price contracts suit variable quantities and require a bill of quantities.
Progress payment and retention: interim certificates based on measured work, with retention (typically 5–10 %) released after the defects liability period.
Public Infrastructure, Transportation, and Water Systems
Road geometric design: design speed determines minimum horizontal radius R = V²/(127·(e + f)); vertical curves use stopping sight distance.
Pavement design: traffic loading in equivalent standard axles (ESAL); flexible pavement layers (subbase, base, asphalt) sized from the design traffic and subgrade strength.
Drainage: rational method Q = C·i·A for small catchments; return periods are typically 2–10 years for urban drainage and higher for major structures.
Water supply: demand per capita, peak factor, minimum residual pressure, and fire-flow requirement; Hazen–Williams or Darcy–Weisbach for head loss.
Wastewater: separate vs combined systems; design flow = average dry-weather flow × peak factor plus infiltration; self-cleansing velocity about 0.6–1.0 m/s at minimum flow.
Bridges: load model per Eurocode 1 (LM1), with dynamic amplification, temperature, and braking forces; scour check at piers is mandatory.
Rail: horizontal and vertical alignment governed by cant, transition length, and maximum gradient; level crossings require sight-distance checks.
Water treatment: screening, coagulation/flocculation, sedimentation, filtration, disinfection; turbidity and residual chlorine are key compliance parameters.
Occupational Safety, Fire Protection, and Environmental Protection
Hierarchy of control: eliminate, substitute, engineering controls, administrative controls, then personal protective equipment as the last line of defence.
Work at height: collective protection (guardrails, nets) preferred over personal fall arrest; anchor points and rescue plans are required.
Excavations: shoring or battering for depths beyond about 1.5 m; daily inspection, edge protection, and keeping spoil away from the edge.
Fire protection: passive measures (compartmentation, fire doors, protected escape routes) plus active measures (detection, sprinklers, hydrants); structural fire resistance rated in minutes (R 30/60/90).
Fire safety documentation: fire safety study/elaborate is required before the building permit; it defines escape routes, fire compartments, and equipment.
Hazardous substances: safety data sheets, storage segregation, and spill containment; asbestos and lead surveys precede demolition or refurbishment.
Environmental impact: EIA screening and, where required, a full EIA with public consultation precede approval for major projects; mitigation measures enter the permit conditions.
Construction waste: separate collection, reuse of excavated material where suitable, and disposal only at authorized sites with waste tracking records.
Professional Ethics, Legal Framework, and Practice Regulation
Licensed practice in Bosnia and Herzegovina is regulated by entity-level laws: the Law on Spatial Planning and Construction (FBiH), the Law on Construction and Physical Planning (RS), and cantonal implementing acts; the Brčko District has its own construction law.
Engineers and architects are enrolled in entity chambers (Chamber of Engineers/Chamber of Architects); practicing without a licence or beyond the licensed scope is a misdemeanour subject to fines and possible ban.
Continuing professional development (CPD) is a condition for licence renewal, typically requiring a set number of credit hours per year verified by the chamber.
Core ethical duties: competence within one's field, truthfulness of documentation, avoidance of conflicts of interest, confidentiality of client data, and refusal to certify work one has not verified.
Conflict of interest rule: a designer or supervisor may not certify, review, or approve work in which they or a close associate has a financial interest.
Professional liability: designers and supervisors bear liability for defects caused by their error; liability insurance is required or strongly recommended for practice and for public procurement participation.
Signing and stamping drawings, calculations, and supervision reports is a personal act; the licence holder is accountable for content and may not delegate the signature.
Public procurement of design and supervision services follows the BiH Law on Public Procurement; abnormally low fees that compromise safety are an ethics violation even where legally permitted.
Structural Analysis and Design
Eurocode basis: design value of resistance R_d = R_k/γ_M and design effect E_d = γ_F·E_k; partial factors for persistent actions are typically γ_G = 1.35 and γ_Q = 1.50.
Ultimate limit state check: E_d ≤ R_d; serviceability check: E_d,ser ≤ C_d (deflection, crack width, vibration limits per Eurocode 2/3/5).
Equilibrium and static determinacy: a plane structure is statically determinate when 3 reactions ≥ 3 and internal releases balance; degree of indeterminacy = (3m + r) − (3j + releases).
Superposition applies only to linear elastic systems; second-order (P-Δ) effects must be included when the elastic critical load factor α_cr < 10 (or per national annex).
Concrete: f_cd = α_cc·f_ck/γ_C with γ_C ≈ 1.5; f_ctm from f_ck; minimum reinforcement A_s,min = max(0.26·f_ctm/f_yk, 0.0013)·b·d.
Steel: cross-section resistance uses f_y/γ_M0; member buckling uses χ from the relevant buckling curve and N_b,Rd = χ·A·f_y/γ_M1.
Seismic design: base shear per Eurocode 8, F_b = S_d(T1)·m·λ; behaviour factor q reduces elastic forces; capacity design enforces ductile hierarchy of failure.
Load combinations: persistent/transient use ψ factors for accompanying variable actions; accidental and seismic combinations use ψ2 and reduced partial factors.
Geotechnical Engineering and Foundations
Bearing capacity (drained): q_ult = c'·N_c + q'·N_q + 0.5·γ'·B·N_γ; undrained clay uses q_ult = c_u·N_c + q with N_c ≈ 5.14 for strip footings.
Allowable bearing pressure = q_ult/FS with FS typically 2.5–3.0 for shallow foundations; settlement must also be checked against serviceability limits.
Terzaghi one-dimensional consolidation: S = C_c/(1+e_0)·H·log10((σ'_0+Δσ)/σ'_0) for normally consolidated clay.
Effective stress principle: σ' = σ − u; all strength and stiffness parameters (c', φ', E') are expressed in effective terms for drained conditions.
Liquefaction screening: saturated loose sands below the water table with (N1)60 < 15–20 and groundwater shallower than about 10 m are potentially liquefiable under strong shaking.
Pile capacity: Q_ult = Q_b + Q_s = q_b·A_b + Σ f_s·A_s; group effects reduce capacity and increase settlement relative to single piles.
Earth pressure: Rankine active K_a = tan²(45° − φ/2), passive K_p = tan²(45° + φ/2); at-rest K_0 ≈ 1 − sin φ for normally consolidated soil.
Slope stability: factor of safety F = resisting shear / driving shear; Bishop simplified method is standard for circular slip surfaces, with F ≥ 1.3–1.5 depending on consequence.
Construction Materials, Testing, and Quality Control
Concrete conformity: cube strength f_ck,cyl ≈ 0.8·f_ck,cube; conformity assessed on groups of results per EN 206 with characteristic strength and minimum individual values.
Slump/flow tests assess workability; air content, density, and temperature are routine fresh-concrete checks; specimens cure 28 days at 20 ± 2 °C before compressive testing.
Rebar testing: tensile test gives yield strength R_eH, tensile strength R_m, and elongation A; characteristic values must meet the declared class (e.g., B500B).
Steel structures: welds are checked by visual, ultrasonic, or radiographic methods; bolted connections by torque or tension calibration per the specified class.
Soil compaction control: Proctor (standard or modified) determines maximum dry density and optimum moisture; field density by sand-replacement or nuclear gauge; acceptance requires ≥ 95–98 % of Proctor maximum.
Aggregate tests: grading curve, fineness modulus, Los Angeles abrasion, and flakiness index; alkali–silica reactivity screening for reactive aggregates.
Bituminous mixtures: Marshall stability and flow, air voids, and binder content; compaction degree checked by core density against reference density.
Non-destructive testing: rebound hammer and ultrasonic pulse velocity give indicative strength; cores are required for arbitration or where NDT results are doubtful.
Building Physics, Services, and Energy Efficiency
Thermal transmittance U = 1/R_total; R = d/λ per layer plus surface resistances; lower U means better insulation, and national energy rules set maximum U-values per element.
Thermal bridging: linear thermal transmittance ψ adds to transmission loss; Ψ·l must be included in the envelope heat-loss calculation.
Moisture: Glaser method checks interstitial condensation by comparing vapour pressure to saturation pressure through the assembly; a continuous vapour barrier is placed on the warm side.
Ventilation heat loss Q_v = ρ·c_p·V̇·ΔT; required fresh-air rate follows occupancy and hygiene standards, with heat recovery reducing the loss.
Heating load: transmission plus ventilation losses minus internal and solar gains; boiler and distribution efficiency reduce the delivered energy requirement.
Energy performance certificate (EPC) rates the building from A to G based on primary energy and CO2; nearly zero-energy building (nZEB) targets apply to new construction.
Acoustic insulation: airborne sound reduction index R_w and impact sound level L_n,w; flanking transmission often governs and must be checked separately.
Daylight and lighting: daylight factor = interior illuminance / unobstructed horizontal exterior illuminance × 100; minimum values depend on room use.
Architectural Design, Planning, and Urbanism
Spatial plan hierarchy in BiH: state-level, entity spatial plan, cantonal/regional plan, municipal spatial plan, and urbanistic plan (regulacioni plan) with detailed building rules.
Building rules: buildable area, building line, setback from plot boundaries, height and floor-area ratio (FAR = gross floor area / plot area), and coefficient of built-up area (footprint / plot area).
Accessibility: ramps at ≤ 1:20 slope (1:12 for short runs), minimum clear widths, tactile guidance, and accessible sanitary facilities are mandatory for public buildings.
Fire and life safety in layout: maximum travel distance to an exit, exit width per occupant, compartment size limits, and smoke-ventilated stairs must be checked at concept stage.
Urban mobility: street cross-sections allocate carriageway, parking, sidewalks, and green strips; parking norms per use (e.g., spaces per dwelling or per 100 m² of office) are set locally.
Heritage protection: buildings in protected zones or on the register require conservation approval; interventions must preserve authentic fabric and character.
Solar orientation and microclimate: principal glazing within about 30° of south, shading for summer overheating, and wind protection at entrances.
Public participation: draft spatial and urban plans are subject to public review before adoption; objections must be addressed in the plan documentation.
Construction Technology, Organization, and Management
Critical path method: total float = LS − ES = LF − EF; activities with zero total float form the critical path and drive project duration.
Earned value: CPI = EV/AC, SPI = EV/PV; CPI < 1 means cost overrun, SPI < 1 means schedule slippage.
Concrete construction sequence: formwork, reinforcement, placing, compaction, curing; striking time depends on strength gain and member type.
Earthworks: cut-and-fill balance minimizes haul; compaction in layers of 20–30 cm with moisture control near optimum.
Site layout: crane coverage, material storage, access roads, and temporary facilities must respect safety distances and not obstruct fire access.
Quality plan: inspection and test plan (ITP) defines hold points, witness points, and records for each activity; non-conformities are logged and closed before handover.
Contract types: lump-sum, unit-price (measured), and cost-plus; unit-price contracts suit variable quantities and require a bill of quantities.
Progress payment and retention: interim certificates based on measured work, with retention (typically 5–10 %) released after the defects liability period.
Public Infrastructure, Transportation, and Water Systems
Road geometric design: design speed determines minimum horizontal radius R = V²/(127·(e + f)); vertical curves use stopping sight distance.
Pavement design: traffic loading in equivalent standard axles (ESAL); flexible pavement layers (subbase, base, asphalt) sized from the design traffic and subgrade strength.
Drainage: rational method Q = C·i·A for small catchments; return periods are typically 2–10 years for urban drainage and higher for major structures.
Water supply: demand per capita, peak factor, minimum residual pressure, and fire-flow requirement; Hazen–Williams or Darcy–Weisbach for head loss.
Wastewater: separate vs combined systems; design flow = average dry-weather flow × peak factor plus infiltration; self-cleansing velocity about 0.6–1.0 m/s at minimum flow.
Bridges: load model per Eurocode 1 (LM1), with dynamic amplification, temperature, and braking forces; scour check at piers is mandatory.
Rail: horizontal and vertical alignment governed by cant, transition length, and maximum gradient; level crossings require sight-distance checks.
Water treatment: screening, coagulation/flocculation, sedimentation, filtration, disinfection; turbidity and residual chlorine are key compliance parameters.
Occupational Safety, Fire Protection, and Environmental Protection
Hierarchy of control: eliminate, substitute, engineering controls, administrative controls, then personal protective equipment as the last line of defence.
Work at height: collective protection (guardrails, nets) preferred over personal fall arrest; anchor points and rescue plans are required.
Excavations: shoring or battering for depths beyond about 1.5 m; daily inspection, edge protection, and keeping spoil away from the edge.
Fire protection: passive measures (compartmentation, fire doors, protected escape routes) plus active measures (detection, sprinklers, hydrants); structural fire resistance rated in minutes (R 30/60/90).
Fire safety documentation: fire safety study/elaborate is required before the building permit; it defines escape routes, fire compartments, and equipment.
Hazardous substances: safety data sheets, storage segregation, and spill containment; asbestos and lead surveys precede demolition or refurbishment.
Environmental impact: EIA screening and, where required, a full EIA with public consultation precede approval for major projects; mitigation measures enter the permit conditions.
Construction waste: separate collection, reuse of excavated material where suitable, and disposal only at authorized sites with waste tracking records.