BPI Heating flashcards
BPI Heating · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Sensible heat formula
- Btu/h equals 1.08 times CFM times the temperature difference for standard air; it converts measured airflow and temperature change into delivered heating capacity.
- AFUE
- Annual Fuel Utilization Efficiency: a seasonal efficiency rating that includes steady-state combustion losses plus cycling, standby, and off-cycle losses, so it is always lower than measured combustion efficiency.
- Stack effect
- Buoyancy of warm indoor air creates upward pressure in a building; the neutral pressure plane is where indoor and outdoor pressures match and shifts with leakage and exhaust operation.
- Thermal bridge
- A high-conductance path such as framing or a steel stud that bypasses insulation and lowers whole-assembly R-value; it appears as cold stripes on a thermal image.
- Vent category I
- A venting classification for appliances operating with negative vent pressure and non-condensing flue gases, typically natural-draft furnaces and boilers connected to a vertical chimney.
- Design heat load
- The calculated Btu/h needed to hold indoor design temperature at the outdoor design temperature, summing envelope transmission plus infiltration and ventilation loads for the whole house.
- Stoichiometric air
- The exact air quantity required for complete combustion with no oxygen left over; natural gas needs roughly ten cubic feet of air per cubic foot of gas.
- Air-free CO
- Measured CO multiplied by 20.9 and divided by (20.9 minus O2); this removes the effect of dilution so flue readings from different appliances can be compared to a single limit.
- Draft hood spillage
- Flue gases escaping the draft hood relief opening into the room rather than up the vent; spillage indicates depressurization, blockage, or an undersized vent and must be corrected.
- Combustion air opening
- A permanent opening supplying burner air; the rule is one square inch of free area per 1,000 Btu/h input, using high and low openings for confined spaces.
- CAZ depressurization limit
- BPI caps worst-case depressurization of a combustion appliance zone at about five pascals; more negative pressure risks backdrafting natural-draft appliances and requires mitigation.
- ASHRAE 62.2 ventilation rate
- Whole-house mechanical ventilation formula: 0.01 times conditioned floor area plus 7.5 times the number of bedrooms plus one, expressed in cubic feet per minute.
- Manifold pressure, natural gas
- The pressure delivered to the burners of a natural gas appliance, typically 3.5 inches water column; verify at the valve outlet with a manometer while the unit runs.
- Vent connector slope
- A single-wall or listed connector must rise at least one quarter inch per foot of run toward the chimney so flue gases travel upward and condensate does not pool.
- Sediment trap
- A drip leg installed at the appliance gas inlet that catches dirt, pipe scale, and moisture before they can reach the gas valve or burner orifices.
- Condensate trap, Category IV
- A 90%-plus furnace produces acidic condensate that drains through a trapped line pitched back to the unit; the trap also keeps flue gas from escaping into the airstream.
- Temperature rise range
- Nameplate specification giving the acceptable supply-minus-return air temperature difference; a reading outside the range signals wrong airflow, wrong gas pressure, or a fouled heat exchanger.
- Return air prohibition
- Return air cannot be drawn from bathrooms, kitchens, garages, or rooms with combustion appliances because it spreads moisture, odors, and carbon monoxide through the house.
- Excess air calculation
- Percent excess air approximates O2 divided by (20.9 minus O2), times 100 for natural gas; values near 25 to 50 percent suit atmospheric burners.
- Temperature rise measurement
- Supply temperature minus return temperature, read after 10 to 15 minutes of steady operation with probes placed out of direct radiant view of the heat exchanger.
- Airflow from temperature rise
- CFM equals output Btu/h divided by 1.08 times the temperature rise; use nameplate output and the measured rise to check delivered airflow.
- Total external static pressure
- Supply static plus return static, with signs treated as absolute values; compare against the blower fan curve to see whether the duct system is restricting airflow.
- ACH50
- Air changes per hour at 50 pascals, computed as CFM50 times 60 divided by conditioned volume; a common blower-door metric of envelope air tightness.
- Duct leakage, CFM25
- Duct blaster airflow needed to hold the duct system at 25 pascals; compare with system airflow, since leakage above about 10 percent deserves sealing.
- Inch of water column
- A pressure unit used for gas and air measurement; one inch of water column equals about 249 pascals, and 0.004 inches equals roughly one pascal.
- Steady-state combustion efficiency
- Efficiency calculated from flue oxygen, stack temperature, and ambient temperature; it ignores cycling and jacket losses and therefore overstates the seasonal AFUE rating.
- Heat anticipator setting
- A thermostat adjustment matched to the current draw of the gas valve, typically 0.2 to 0.8 amps; set too high it shortens cycles, set too low it causes overshoot.
- Flame rectification current
- The microamp signal a flame sensor returns to the control module, normally 1 to 10 microamps; below roughly half a microamp the gas valve closes.
- Fan limit switch
- A temperature-actuated control that starts the blower near 130°F, stops it near 100°F, and opens a high limit around 200°F to protect the heat exchanger.
- Manual D friction rate
- Available static pressure divided by the total effective length of the longest duct run; the resulting friction rate in inches of water per 100 feet sizes each duct section.
- Commissioning documentation
- A written record of nameplate data, combustion readings, temperature rise, static pressures, and defects found, dated and signed, then reviewed with the homeowner at completion.
- Sequence of operation
- A call for heat energizes the inducer, a pressure switch proves draft, ignition lights the burners, flame is proven, and the blower starts when the fan switch reaches temperature.