BPI Heating key terms
BPI Heating · Get comfortable with the vocabulary.
- Thermal boundary
- Related: Air barrier, R-value, Stack effect
The continuous layer of insulation, air sealing, and building materials that separates heated indoor space from unconditioned or outdoor space. It controls heat loss and marks where insulation and air control should align.
- Stack effect
- Related: Thermal boundary, Draft, Combustion air
The upward movement of indoor air caused by warm air being lighter than cold outdoor air. It creates pressure differences across the building shell, drawing air in low and pushing it out high.
- Air barrier
- Related: Thermal boundary, Stack effect, R-value
A continuous building layer that blocks uncontrolled air movement through the enclosure. It is separate from insulation and must connect across walls, ceilings, floors, and penetrations to work.
- R-value
- Related: Thermal boundary, Air barrier
A measure of a material's resistance to heat flow. Higher numbers mean better insulation performance; the value depends on material type, thickness, and installed condition.
- Heating degree day
- Related: Design heat load, AFUE
A weather-based measure of how much heating is needed. It is calculated from the difference between a base indoor temperature and the average outdoor temperature over a day.
- Sensible heat
- Related: Temperature rise, Heating degree day
Heat energy that changes the temperature of air or another substance without changing its phase. It is the part of heating load that thermometers directly indicate.
- Design heat load
- Related: Heating degree day, Temperature rise
The estimated heat loss of a building at a selected cold outdoor design temperature and desired indoor temperature. It is used to size heating equipment and distribution components.
- Combustion air
- Related: Draft, Excess air, Backdrafting
Air supplied to a burner, appliance, or combustion zone to provide oxygen for burning fuel. Insufficient combustion air can cause incomplete combustion and carbon monoxide production.
- Draft
- Related: Stack effect, Draft hood, Barometric damper
The pressure difference that moves air and flue gases through a vent or chimney. It is produced by temperature differences and by fans, and it must be adequate without being excessive.
- Flue gas
- Related: Carbon monoxide, Combustion analysis, Draft
The mixture of gases and water vapor produced by burning fuel and carried away through the vent. It contains products such as carbon dioxide, water vapor, nitrogen, and sometimes carbon monoxide.
- Carbon monoxide
- Related: Flue gas, Air-free CO, Spillage
A colorless, odorless gas produced by incomplete combustion. It is toxic because it binds to hemoglobin and reduces the blood's ability to carry oxygen.
- Spillage
- Related: Backdrafting, Draft hood, Carbon monoxide
Flue gases escaping from a draft hood or vent connector into the room instead of going up the vent. Spillage can introduce carbon monoxide and moisture into indoor air.
- Backdrafting
- Related: Spillage, Worst-case depressurization test, Combustion air
A condition where flue gases are pulled down or reversed through a vent into the building. It is often caused by depressurization or by a blocked or poorly designed venting system.
- Excess air
- Related: Combustion air, Combustion analysis, Carbon monoxide
Air supplied to combustion beyond the amount theoretically needed for complete burning. Some excess air is normal and helps ensure complete combustion, but too much lowers efficiency.
- Draft hood
- Related: Draft, Spillage, Barometric damper
A device at the outlet of some appliances that provides dilution air and stabilizes draft. It also allows flue gases to spill if venting is obstructed or building pressure is unfavorable.
- Barometric damper
- Related: Draft, Draft hood, Flue gas
A hinged flap installed in a flue connector that opens to admit room air and stabilize draft. It is common on oil appliances and some gas appliances, and it must be adjusted correctly.
- Clearance to combustibles
- Related: Category I appliance, Draft hood
The minimum safe distance between an appliance or vent and materials that can catch fire. It is specified by the manufacturer and by code and must be maintained during installation.
- Category I appliance
- Related: Clearance to combustibles, Draft hood, Flue gas
A gas appliance that operates with negative vent pressure and produces flue gases cool enough to avoid condensation in the vent. It typically vents into a vertical chimney or B-vent.
- Condensing furnace
- Related: Heat exchanger, AFUE, Flue gas
A high-efficiency furnace that cools flue gases enough to condense water vapor and recover latent heat. It uses a secondary heat exchanger and must be vented with compatible materials.
- Heat exchanger
- Related: Condensing furnace, Carbon monoxide, Temperature rise
The metal assembly that separates combustion gases from indoor air while transferring heat. Cracks or holes can allow flue gases to enter the supply air stream.
- Manifold pressure
- Related: Clocking the gas meter, Combustion analysis
The gas pressure measured at the appliance manifold, downstream of the gas valve. It must match the manufacturer's rating for the fuel type and is adjusted during setup.
- Limit switch
- Related: Temperature rise, Heat exchanger
A safety control that opens the burner circuit when temperature or another limit exceeds a set point. It shuts down heating to prevent overheating or unsafe operation.
- Induced draft blower
- Related: Draft, Static pressure, Flue gas
A fan that pulls flue gases through the appliance and creates negative pressure in the vent. It is common on fan-assisted furnaces and must prove airflow before the burner stays on.
- Combustion analysis
- Related: Carbon monoxide, Excess air, Air-free CO
The measurement of flue gas composition and temperature to evaluate combustion safety and efficiency. It typically includes oxygen, carbon dioxide, carbon monoxide, and stack temperature readings.
- Static pressure
- Related: Temperature rise, Return duct, Induced draft blower
The outward force exerted by air against duct walls, measured in inches of water column. It is used to check fan performance, duct restrictions, and airflow problems.
- Temperature rise
- Related: Static pressure, Heat exchanger, Limit switch
The difference between supply-air and return-air temperatures across a heating appliance or system. It shows whether airflow and heating output are within the manufacturer's specified range.
- AFUE
- Related: Condensing furnace, Heating degree day, Design heat load
Annual fuel utilization efficiency, a rating that estimates how much fuel energy becomes useful heat over a typical heating season. Higher values indicate greater efficiency.
- Clocking the gas meter
- Related: Manifold pressure, Combustion analysis
A field method of measuring gas input by timing the meter dial while other appliances are off. The result is compared with the appliance rating to confirm proper input.
- Air-free CO
- Related: Carbon monoxide, Combustion analysis, Spillage
A carbon monoxide reading calculated as if no excess air were present in the sample. It allows comparison of CO levels from different combustion conditions and appliances.
- Worst-case depressurization test
- Related: Backdrafting, Spillage, Combustion air
A procedure that creates the strongest realistic negative pressure in a combustion appliance zone. It checks whether exhaust fans, ducts, or other forces can cause backdrafting or spillage.
- Plenum
- Related: Static pressure, Return duct, Temperature rise
A box or chamber attached to the furnace outlet or inlet that distributes air to ducts. Supply and return plenums must be sealed and sized to support proper airflow.
- Return duct
- Related: Plenum, Static pressure, Damper
Ductwork that carries air from conditioned rooms back to the furnace or air handler. Leaky returns can draw in unconditioned air or create pressure problems.
- Damper
- Related: Zoning, Return duct, Plenum
A movable plate or blade inside ductwork or a vent that adjusts airflow. Dampers can be manual or motorized and are used for balancing, zoning, or shutoff.
- Zoning
- Related: Damper, Thermostat, Plenum
Dividing a building into separate control areas with individual thermostats and dampers or valves. Zoning improves comfort but requires correct bypass or airflow management.
- Thermostat
- Related: Zoning, Aquastat
A control that senses room temperature and signals the heating system to start or stop. It may include setback schedules, fan control, and anticipation settings.
- Aquastat
- Related: Thermostat, Outdoor reset
A temperature control used on hydronic boilers to start and stop the burner or circulator. It helps maintain water temperature within a safe and useful range.
- Outdoor reset
- Related: Aquastat, Condensing furnace
A boiler control strategy that lowers supply-water temperature as outdoor temperature rises. It improves efficiency and comfort by matching heat output to building load.