- Building Code Act purpose
- Ontario statute that authorizes the building code, establishes the chief building official and inspectors, and provides enforcement powers including orders to comply and stop-work orders.
- Part 8 scope
- Division B Part 8 governs sewage systems serving one lot with design capacity of 10,000 litres per day or less, covering treatment, distribution, and dispersal requirements.
- Sewage system definition
- A system for the treatment and disposal of sewage serving a single lot, including treatment units, distribution piping, and dispersal components such as leaching beds.
- Permit before construction
- A building permit must be obtained from the principal authority before constructing, extending, altering, or repairing a sewage system, and work must follow approved plans.
- Site evaluation purpose
- An assessment of soil texture, permeability, depth to bedrock and water table, slope, and lot size that determines the feasible system type and size.
- Percolation rate (T-time)
- The time in minutes for water in a test hole to drop 25 millimetres, used to classify soil permeability and size the dispersal area.
- Seasonal high water table
- The highest expected groundwater elevation, determined from soil mottling, monitoring wells, or local records, which sets the minimum trench bottom elevation.
- Reserve area requirement
- An identified and protected area of comparable size to the primary dispersal area, kept available for a replacement system if the original fails.
- Design daily flow
- The estimated volume of sewage produced per day, based on bedrooms, fixtures, or occupancy, used to size the tank and dispersal area.
- Hydraulic loading rate
- The volume of effluent applied per unit area of soil per day, selected from soil texture and treatment level to size the dispersal area.
- Typical residential sewage strength
- Residential sewage commonly contains about 200 to 300 mg/L BOD5 and 200 to 300 mg/L suspended solids, with grease and settleable solids removed in the tank.
- Clear water prohibition
- Footing drains, roof leaders, and other clear-water sources shall not be connected to the sewage system because they overload the tank and dispersal area.
- Septic tank retention time
- A tank provides at least about 24 hours of liquid retention at design flow, allowing solids to settle and scum to float before effluent exits.
- Minimum tank capacity
- Part 8 sets a minimum tank volume, typically 3,600 litres for a single-family dwelling, with additional capacity for extra bedrooms or fixtures.
- Tank pumping trigger
- The tank should be pumped when combined sludge and scum depth reaches about one-third of the tank depth, to protect the dispersal field.
- Effluent filter function
- A device at the tank outlet that captures fine solids, reducing loading to the dispersal field, and requires regular cleaning to prevent backup.
- Leaching bed definition
- A dispersal system of distribution pipe in gravel-filled trenches, sized by daily flow and soil loading rate, with level or uniformly sloped perforated pipe.
- Filter bed purpose
- A dispersal system using sand or other filter medium to provide additional treatment where native soil is marginal, improving effluent quality before it reaches groundwater.
- Mound system definition
- A raised dispersal system built with sand fill above natural grade, used where bedrock or the water table is too close to the surface for a conventional bed.
- Distribution box function
- A level, accessible box that divides effluent equally among distribution pipes or trenches, preventing one trench from receiving disproportionate flow.
- Dose volume basis
- The batch volume delivered per pump cycle, typically the distribution pipe volume plus a fraction of daily flow, sized to rest the soil between doses.
- Total dynamic head
- The sum of static lift and friction losses in the discharge line, used with the required dose rate to select a pump.
- Pump chamber alarm
- A high-level float and alarm that warns of pump failure or high water in the chamber, set below the inlet invert to prevent backup into the building.
- Check valve requirement
- A valve on the pump discharge that prevents effluent from flowing back into the chamber, paired with an isolation valve for maintenance.
- Well setback purpose
- A required horizontal distance between a sewage system and a drinking-water well, larger than most other setbacks, to protect water quality from contamination.
- Surface water setback
- A specified minimum horizontal distance from a leaching bed to a watercourse, lake, or pond, intended to protect surface water from nutrient and pathogen loading.
- System location restrictions
- Sewage systems shall not be placed under driveways, parking areas, or buildings, and must remain accessible for maintenance and inspection.
- Setback measurement basis
- Setbacks are measured horizontally from the system component, such as the trench edge or tank wall, to the feature, and must be shown on the site plan.
- Required inspection stages
- Inspections are required before covering the tank, before covering distribution piping, and at final completion; work must not be covered before authorization.
- Failure indicators
- Surfacing effluent, odour, slow drains, and soggy ground over the dispersal area indicate system failure and require prompt investigation and repair.
- Site plan contents
- A drawing showing lot boundaries, buildings, wells, watercourses, setbacks, system layout, and reserve area, submitted with the permit application.
- Permit amendment
- A required approval for changes to approved plans; work must not proceed on the changed portion until the amendment is issued.