OBC On-site Sewage Systems study materials
OBC On-site Sewage Systems study resources

OBC On-site Sewage Systems key terms

OBC On-site Sewage Systems · Get comfortable with the vocabulary.

Building Code Act

Ontario statute that authorizes the Building Code, establishes the powers of building officials, and sets out permit, inspection, and enforcement duties for construction, including on-site sewage systems.

Related: Permit to Construct, Chief Building Official
Permit to Construct

Written municipal authorization required before installing or altering a sewage system, issued after review of an application, plans, site information, and required fees, and subject to stated conditions.

Related: Building Code Act, Site Evaluation Report
Chief Building Official

Municipal officer appointed under the Building Code Act who administers and enforces the Code, issues permits, conducts inspections, and may order compliance or stop-work action.

Related: Building Code Act, Order to Comply
Order to Comply

Written direction from a building official requiring correction of a contravention of the Building Code Act or Code, such as work without a permit or an unsafe installation.

Related: Chief Building Official, Permit to Construct
Sewage System

Part 8 defines this as a system for collecting, treating, or disposing of sewage, including treatment units, tanks, distribution piping, and dispersal works serving a building.

Related: Class 4 Sewage System, Holding Tank
Class 4 Sewage System

A system that treats sewage in a septic tank or treatment unit and discharges effluent to a leaching bed or filter bed for subsurface disposal in soil.

Related: Leaching Bed, Treatment Unit
Holding Tank

A watertight tank with no outlet that stores sewage until it is pumped out and hauled away, used where soil or site conditions cannot support on-site treatment and dispersal.

Related: Sewage System, Septage
Treatment Unit

A device or tank, such as a septic tank or packaged aerobic unit, that receives raw sewage and provides primary or secondary treatment before discharge to dispersal works.

Related: Septic Tank, Effluent Filter
Septic Tank

A watertight settling tank that separates solids, floats grease and scum, and allows partially clarified liquid to flow onward for further treatment or dispersal.

Related: Treatment Unit, Sludge and Scum
Effluent Filter

A removable screening device installed at a septic tank outlet that retains suspended solids, protecting downstream distribution piping and dispersal soil from clogging.

Related: Septic Tank, Leaching Bed
Sludge and Scum

Solids that settle to the tank bottom and buoyant fats and greases that collect at the surface; both accumulate over time and must be removed by pumping.

Related: Septic Tank, Septage
Septage

The accumulated sludge, scum, and liquid removed from a septic or holding tank by a licensed hauler for treatment or disposal at an approved facility.

Related: Holding Tank, Sludge and Scum
Hydraulic Loading Rate

The volume of effluent applied per unit area of dispersal surface per day, used to size leaching beds and other systems so soil can accept and treat the flow.

Related: Design Flow, Soil Percolation Rate
Design Flow

The daily sewage volume a system must handle, calculated from fixture units, occupancy, or prescribed per-person or per-bedroom allowances under the Code.

Related: Hydraulic Loading Rate, Fixture Unit
Fixture Unit

A relative measure of the load a plumbing fixture places on a drainage system, used to total building flow and establish the required sewage system capacity.

Related: Design Flow, Daily Design Flow
Daily Design Flow

The estimated quantity of sewage produced per day used for sizing treatment and dispersal components, derived from occupancy type and Code allowances.

Related: Design Flow, Hydraulic Loading Rate
Site Evaluation

Field investigation of soil texture, depth, permeability, slope, water table, and setbacks that determines whether a site can support a sewage system and what type fits.

Related: Soil Percolation Rate, Test Pit
Test Pit

An excavated inspection hole used to observe soil horizons, depth to bedrock or water table, and other limiting conditions during a site evaluation.

Related: Site Evaluation, Soil Percolation Rate
Soil Percolation Rate

A measure of how quickly soil absorbs water, determined by a percolation test or estimated from soil texture, used to size dispersal areas.

Related: Hydraulic Loading Rate, Site Evaluation
Seasonal High Water Table

The highest level groundwater reaches during the year, a limiting condition that constrains separation distances and may rule out conventional subsurface dispersal.

Related: Site Evaluation, Mound System
Leaching Bed

A subsurface dispersal system of perforated distribution pipe laid in gravel or chambers within trenches, where effluent seeps into and is treated by surrounding soil.

Related: Distribution Pipe, Class 4 Sewage System
Filter Bed

A dispersal system using a bed of sand or other filtering medium with distribution piping, providing treatment before effluent reaches underlying soil.

Related: Leaching Bed, Mound System
Mound System

An elevated dispersal system built above natural grade with a sand fill and distribution bed, used where separation to limiting conditions is inadequate at the surface.

Related: Seasonal High Water Table, Filter Bed
Distribution Pipe

Perforated or orifice-equipped piping that spreads effluent evenly along a leaching bed, filter bed, or mound so the soil receives flow uniformly.

Related: Leaching Bed, Dosing
Dosing

Delivering effluent to dispersal works in controlled batches rather than continuously, improving distribution, resting the soil, and supporting even loading.

Related: Distribution Pipe, Dosing Pump
Dosing Pump

A pump, often in a pump chamber after the treatment unit, that lifts and delivers measured volumes of effluent to distribution piping on a timed or demand basis.

Related: Dosing, Pump Chamber
Pump Chamber

A watertight basin that receives treated effluent and houses a pump, floats, and controls for delivering sewage to dispersal works or a higher point of discharge.

Related: Dosing Pump, Alarm
Setback

The minimum required horizontal distance between a sewage system component and a feature such as a well, watercourse, property line, or building.

Related: Clearance, Site Evaluation
Clearance

The required separation distance between system components and other objects or conditions, including wells, trees, slopes, and structures, to protect health and function.

Related: Setback, Seasonal High Water Table
Certificate of Inspection

Documentation issued by the building official confirming that completed installation was inspected and complies with the permit and applicable Code requirements.

Related: Permit to Construct, As-Built Drawing
As-Built Drawing

A drawing recording the actual installed location, dimensions, and components of a sewage system, submitted to document completed work for the permit file.

Related: Certificate of Inspection, Site Evaluation Report
Site Evaluation Report

A written record of site investigation findings, including soil conditions, test pit observations, and constraints, submitted with a permit application to support design decisions.

Related: Site Evaluation, Permit to Construct
Maintenance Inspection

Periodic checking of tanks, pumps, filters, and dispersal areas to confirm the system operates properly, identify needed pumping or repairs, and prevent premature failure.

Related: Effluent Filter, Septic Tank
Alarm

An audible or visual warning device that signals high liquid level or pump fault in a pump chamber or treatment unit so occupants can act before sewage backs up.

Related: Pump Chamber, Dosing Pump
Greywater

Wastewater from sinks, showers, baths, and laundry that excludes toilet discharge, sometimes handled by separate systems or reduced-flow designs.

Related: Design Flow, Sewage System
Blackwater

Wastewater containing toilet discharge and often kitchen sink waste, carrying the highest pathogen and organic load and requiring full treatment before dispersal.

Related: Greywater, Septic Tank
Sewage System Alteration

Any change to an existing system, such as replacing a tank, extending a bed, or adding fixtures, that may require a new permit and updated design.

Related: Permit to Construct, As-Built Drawing
Soil Texture Classification

Grouping of soil by proportions of sand, silt, and clay, which influences permeability, treatment capacity, and suitability for subsurface dispersal.

Related: Soil Percolation Rate, Site Evaluation