OBC On-site Sewage Systems: Pumps, Dosing, and Hydraulic Controls

OBC On-site Sewage Systems · Work through your exam, one topic at a time.

All guide sections

Pumps, Dosing, and Hydraulic Controls

Purpose of pumping and dosing

Pumps move effluent where gravity cannot, and dosing delivers it in controlled volumes so the field rests between doses. Dosing improves distribution, reduces ponding, and extends field life. Candidates must understand pump chambers, pump selection against total dynamic head, dose volume, and the relationship between dose volume and the distribution network's capacity.

Controls and alarms

Float or transducer controls set on and off levels. A high-level alarm is essential and must be visible and audible where it will be noticed. Duplex pumps provide redundancy where failure would cause a backup. Check valves and quick-connect unions allow service. Time dosing uses a timer with a counter so the dose volume can be verified. Demand dosing responds to inflow.

Traps in questions

  • Sizing a pump on vertical lift alone, ignoring friction losses in pipe and fittings.
  • Setting a dose volume smaller than the network's minimum to achieve even distribution.
  • Omitting a high-level alarm or placing it where no one hears it.
  • Confusing time dosing with demand dosing.

Rule of thumb

Compute total dynamic head as static lift plus friction, then confirm the selected pump's curve delivers the required dose at that head; verify dose volume against the network's minimum.

Worked example

A pump must lift effluent 2.5 m through pipe and fittings with calculated friction loss of 1.5 m. Total dynamic head is 4.0 m. The designer selects a pump whose curve delivers the required flow at 4.0 m, then sets floats so each dose equals the volume needed to fill the distribution network plus the design dose, and adds a high-level alarm.