PAQE key terms
PAQE · Get comfortable with the vocabulary.
- Programming
- Related: Adjacency Matrix, Net Assignable Area
The pre-design phase in which the architect documents the client's goals, functional requirements, space needs, occupancy counts, and budget constraints, producing a written program that guides all later design decisions.
- Net Assignable Area
- Related: Gross Floor Area, Programming
The usable floor area of spaces that directly serve building occupants, such as offices, labs, and classrooms, excluding circulation, mechanical, and structural zones. It is the basis for space-program area totals.
- Adjacency Matrix
- Related: Programming, Stacking Diagram
A grid that rates the desired proximity or separation between each pair of programmed spaces, helping the designer test bubble diagrams and stacking options against functional relationships before laying out rooms.
- Stacking Diagram
- Related: Adjacency Matrix, Floor Area Ratio
A schematic vertical organization showing which programmed space groups occupy each floor of a multi-story building, used to test core placement, structure, and vertical circulation before floor plans are drawn.
- Floor Area Ratio
- Related: Setback, Gross Floor Area
The ratio of a building's total gross floor area to the area of its lot. Zoning codes use it to cap building bulk, and it directly determines how many floors a given footprint can support.
- Setback
- Related: Floor Area Ratio, Building Envelope
The minimum horizontal distance a building must be held back from a property line, street, or other reference line, established by zoning to protect light, air, and privacy.
- Building Envelope
- Related: Setback, Massing
In zoning, the three-dimensional volume within which a building may rise, defined by setbacks, height limits, and sky-exposure planes. It is distinct from the envelope assembly of walls and roof.
- Massing
- Related: Building Envelope, Stacking Diagram
The overall three-dimensional form and bulk of a building, including its height, width, roof shape, and articulation. Massing studies test how a volume meets zoning limits and fits its context.
- Solar Orientation
- Related: Sun Path Diagram, Daylighting
The relationship of a building's facades and openings to the path of the sun, used to place glazing, shading, and occupied spaces where solar heat gain and daylight are most beneficial.
- Sun Path Diagram
- Related: Solar Orientation, Daylighting
A polar chart plotting the sun's altitude and azimuth for a given latitude across the year, letting designers predict shadow patterns, overheating risk, and shading needs for each facade.
- Daylighting
- Related: Solar Orientation, Glazing Ratio
Designing fenestration, room depth, and surface reflectance so that natural light provides usable illumination for occupants, reducing electric lighting demand while controlling glare and heat gain.
- Glazing Ratio
- Related: Daylighting, U-Value
The area of glass in a wall assembly divided by the gross wall area, used in energy codes to limit heat loss, solar gain, and peak loads attributable to fenestration.
- U-Value
- Related: Thermal Bridging, Glazing Ratio
The overall rate of heat transfer through an assembly per unit area and temperature difference, expressed in units such as Btu/h·ft²·°F. Lower values indicate better insulating performance.
- Thermal Bridging
- Related: U-Value, Continuous Insulation
A path of high-conductivity material, such as a steel stud or slab edge, that bypasses insulation and increases heat flow through an assembly, degrading its effective thermal performance.
- Continuous Insulation
- Related: Thermal Bridging, Vapor Retarder
Rigid insulation placed outboard of the structure and framing, uninterrupted by studs or other conductive elements, to control thermal bridging and improve envelope performance.
- Vapor Retarder
- Related: Continuous Insulation, Air Barrier
A material of low permeance installed to limit moisture vapor diffusion through an assembly, positioned according to climate so that condensation does not form within the wall or roof.
- Air Barrier
- Related: Vapor Retarder, Blower Door Test
A continuous, sealed layer that resists uncontrolled air leakage through the envelope. It is distinct from the vapor retarder, though a single material may serve both functions.
- Blower Door Test
- Related: Air Barrier, Commissioning
A diagnostic test that pressurizes a building with a calibrated fan and measures leakage, expressed as air changes per hour at a reference pressure, to verify envelope airtightness.
- Rain Screen
- Related: Air Barrier, Building Envelope
A wall strategy in which an outer cladding layer sheds most rain while a drained and vented cavity behind it manages any water that penetrates, protecting the backup weather barrier.
- Structural Grid
- Related: Bay Size, Load Path
The regular spacing of columns and beams that establishes bay sizes and load paths, coordinating with parking modules, room layouts, and mechanical distribution in the planning process.
- Bay Size
- Related: Structural Grid, Load Path
The distance between adjacent column lines in either direction, which sets the clear span available for parking, offices, or equipment and strongly influences structural cost and layout flexibility.
- Load Path
- Related: Structural Grid, Lateral System
The continuous route by which gravity, wind, and seismic forces travel from the point of application through structural members down to the foundation and the ground.
- Lateral System
- Related: Load Path, Base Isolation
The structural elements, such as shear walls, braced frames, or moment frames, that resist wind and seismic forces and control building drift and torsion.
- Base Isolation
- Related: Lateral System, Load Path
A seismic strategy in which flexible bearings separate the superstructure from the foundation, lengthening the building's period and reducing the accelerations transmitted during an earthquake.
- Egress Width
- Related: Occupant Load, Means of Egress
The clear width of corridors, stairs, and doors required to carry the occupant load out of a building, calculated from the number of occupants served and the code's capacity factors.
- Occupant Load
- Related: Egress Width, Means of Egress
The number of persons a space is calculated to hold, derived from its floor area and use-based density factors. It drives egress width, exit count, and plumbing fixture counts.
- Means of Egress
- Related: Egress Width, Dead-End Corridor
The continuous and unobstructed path of travel from any point in a building to a public way, comprising exit access, the exit itself, and exit discharge.
- Dead-End Corridor
- Related: Means of Egress, Travel Distance
A corridor segment with only one direction of travel to an exit, permitted only up to a limited length because occupants could be trapped if fire blocks the single path.
- Travel Distance
- Related: Dead-End Corridor, Means of Egress
The measured length of the egress path from the most remote point in a space to the nearest exit, limited by code according to occupancy and whether sprinklers are provided.
- Accessible Route
- Related: Clear Floor Space, Turning Radius
A continuous, unobstructed path connecting accessible elements and spaces, meeting limits on slope, width, surface, and change in level so that a wheelchair user can travel independently.
- Clear Floor Space
- Related: Accessible Route, Turning Radius
The minimum unobstructed area, typically a rectangle sized for a wheelchair, required at fixtures, controls, and doors so a user can approach, use, and turn around.
- Turning Radius
- Related: Clear Floor Space, Accessible Route
The diameter of the circle a wheelchair needs to reverse direction, commonly 60 inches for a full turn, governing the size of vestibules, toilet rooms, and dead-end conditions.
- Specification
- Related: Performance Specification, Basis of Design
The written portion of construction documents describing materials, workmanship, and quality standards, organized by division and coordinated with the drawings to define the contract scope.
- Performance Specification
- Related: Specification, Basis of Design
A specification that states required results, such as fire rating or thermal performance, and leaves the means of achieving them to the contractor, rather than naming a specific product or method.
- Basis of Design
- Related: Performance Specification, Commissioning
A document recording the assumptions, codes, loads, and performance criteria underlying the design, giving reviewers and bidders a verifiable record of what the design must achieve.
- Commissioning
- Related: Blower Door Test, Basis of Design
A quality-assurance process that verifies building systems are installed, tested, and operating according to the owner's requirements and the basis of design before occupancy.
- Standard of Care
- Related: Professional Liability, Scope of Services
The degree of skill and care that a reasonably competent architect would exercise under similar circumstances, which defines the benchmark for judging professional negligence.
- Scope of Services
- Related: Standard of Care, Professional Liability
The written description of work the architect will perform, including phases, deliverables, and exclusions, forming the basis for fees and for limiting responsibility.
- Professional Liability
- Related: Standard of Care, Scope of Services
The exposure of a design professional to claims for economic loss or injury caused by negligent performance, typically insured by errors and omissions coverage rather than general liability.