Graphic scale
A graduated bar printed on the sheet that remains accurate if the drawing is reduced or enlarged; use it rather than the stated ratio to measure distances.
One-eighth inch equals one foot
A drawing ratio of 1:96 in which one-eighth inch on the sheet represents twelve inches of the actual building, common for large floor plans.
Revision cloud
A scalloped line drawn around changed content, tagged with a delta symbol and revision number that matches an entry in the revision block.
Sheet prefix FP
Fire protection drawings. Other common prefixes are A architectural, S structural, M mechanical, E electrical, P plumbing and C civil within the same set.
Hidden line
A dashed line convention showing work above the cut plane or concealed from view, such as overhead ducts, beams, soffits and framing.
Plan review comment
A written finding that cites the code section, identifies the sheet or detail, describes the deficiency, and states the correction required before permit issuance.
Stop work order
A written directive from the code official halting work that is unsafe or proceeding without a permit; it states the reason and is posted at the site.
Certificate of occupancy
A document issued after all final inspections are approved, confirming the building complies with the approved plans and may be occupied for its stated use.
Material and test certificate
A signed contractor form required by NFPA 13 that records flushing, hydrostatic testing and installation details before the system is accepted by the code official.
Inspection record
A dated and signed entry stating what was inspected, by whom, and the result; it is the legal evidence that code compliance was verified in the field.
Rough-in inspection
Field verification of concealed fire protection and life safety work, such as piping, hangers, firestopping and framing, performed before the work is covered by finishes.
Final inspection
The last field verification confirming that systems are complete, tested and operational, and that required certificates, test reports and as-built documents have been submitted.
Hydrostatic test requirement
Sprinkler piping is pressurized at 200 psi for two hours, or at 50 psi above the maximum working pressure where that pressure exceeds 150 psi.
Common path of egress
The distance an occupant must travel before two separate escape routes exist; typically limited to 75 feet, increased to 100 feet in sprinklered business, mercantile and storage occupancies.
Business travel distance limit
Exit access travel distance in Group B occupancies may not exceed 200 feet, or 250 feet where the building is equipped throughout with automatic sprinklers.
High-rise building threshold
A building having an occupied floor more than 75 feet above the lowest level of fire department vehicle access, triggering standpipes, sprinklers and a fire alarm system.
ASTM E119
The standard furnace test that assigns hourly fire-resistance ratings to walls, floors, columns and beams by exposing one side to a controlled fire.
Through-penetration firestop
A tested system, qualified by ASTM E814, that seals openings where pipe, cable or duct passes through a rated wall or floor, restoring the assembly's rating.
Class A interior finish
Material with a flame spread index of 0 to 25 and a smoke developed index of 0 to 450 when tested in accordance with ASTM E84.
Fire door label
A metal tag on the door, frame or hardware stating the hourly rating and the test standard, such as NFPA 252 or UL 10C, to which the assembly was qualified.
Spray fire-resistive material
Coating applied to structural steel that insulates it from fire; the listed thickness and density must be verified against the required hourly rating.
Noncombustible material
A material that passes ASTM E136 testing and contributes negligible fuel, as required for structural members in Type I and Type II construction.
Permit expiration
Under IBC Section 105.5, a permit becomes invalid when work has not started within 180 days of issuance or is suspended for 180 days.
Alternative materials and methods
The provision allowing the code official to approve a design not literally prescribed where it is found equivalent in performance, quality, strength and safety to the code requirement.
Board of appeals
An appointed body that hears challenges to decisions of the code official; it may reverse or modify a decision but cannot set aside code requirements without legal authority.
Deferred submittal
A portion of the design, such as fire alarm calculations or truss shop drawings, left out of the initial permit set and submitted later by a date stated on the plans.
Third-party inspection agency
An approved outside entity that performs inspections or witness tests for the jurisdiction and reports the results in writing to the code official.
Adopted code edition
The version of the building and fire codes and their referenced standards placed into law by ordinance; plans are reviewed against that edition rather than the newest one.
Conflict of interest
A situation where an official's financial interest, family tie or outside employment could affect a decision; the official must disclose it and recuse from the review.
Confidentiality of submitted plans
Proprietary design information must be protected from release except as required by open-records law or for code enforcement proceedings.
Ex parte communication
Contact about a pending permit or appeal made outside the formal record; the official should document it and place it in the file.
Referenced standard
A published document such as NFPA 13 or ASTM E84 that the code adopts by reference; it carries the same enforcement weight as the code text.