F-Gas Category I study plan
F-Gas Category I · Give each week a clear focus.
8 weeks · About 6 hours per week
F-Gas and ODS Regulations - legal duties and environmental obligations & Refrigerant identification, properties and environmental impact
Map each legal duty in the F-Gas and ODS framework to the role that carries it (operator, certified technician, wholesaler)
List the threshold refrigerant charge quantities that trigger leak-check frequency, record-keeping and inspection obligations
Define global warming potential and ozone depletion potential and rank the common refrigerant families by both metrics
Explain the environmental mechanism behind each metric in your own words without notes
Your checkpoint
One-page reference sheet pairing each charge threshold and refrigerant family with the duty or metric that applies, self-tested to 90% accuracy
F-Gas and ODS Regulations - legal duties and environmental obligations & Refrigerant identification, properties and environmental impact
Distinguish the record types an operator must keep (equipment records, service records, recovery and disposal records) and state the retention period for each
Identify which activities legally require a certified person and which do not
Calculate the CO2-equivalent of a given charge from its GWP and mass, working five practice problems
Describe the phase-down schedule for hydrofluorocarbons and what it means for placing new equipment on the market
Your checkpoint
Ten-question self-written quiz on legal duties and refrigerant properties, answered closed-book with a written correction note for every miss
Installation, commissioning and record keeping & Service, maintenance and leak detection
Sequence the commissioning steps for a new system from pre-installation checks through tightness testing and handover
Perform a strength and tightness test calculation using the correct test pressures and hold times
Draft a complete commissioning record including charge, component identification and test results
Select the appropriate leak detection method for a given access situation and justify the choice
Your checkpoint
A filled-in mock commissioning record for a hypothetical split system, complete enough that a second person could audit it
Service, maintenance and leak detection
Build a leak-check schedule for three systems of differing charge sizes and locations
Diagnose five written fault scenarios and identify whether the cause is a leak, a restriction, or a charge issue
Explain how indirect leak-detection methods (pressure, temperature, sight glass, electronic detection) complement each other
State the actions required once a leak is confirmed, including repair timelines and re-testing
Your checkpoint
Leak-check schedule and fault-diagnosis log for the three systems, reviewed against the legal thresholds from week 1
Recovery, recycling, reclaim and disposal of refrigerant
Compare recovery, recycling, reclaim and disposal and state where each is legally and technically appropriate
Describe the recovery procedure for a system from the service valve through cylinder filling, including vapor versus liquid recovery
Identify the purity and handling requirements that determine whether recovered refrigerant can be reused
Explain the decommissioning and disposal path for refrigerant and for the equipment itself
Your checkpoint
A written recovery procedure for one system type, checked step by step against the regulatory requirements and marked pass or fail
Recovery, recycling, reclaim and disposal of refrigerant & Safety, handling and cylinder management
Identify cylinder markings, color codes and valve types and match each to its refrigerant and safe use
State the maximum fill ratio and the safety reason behind it, then calculate the fill limit for two cylinder sizes
List the hazards of common refrigerants (toxicity, flammability, asphyxiation, frostbite) and the control for each
Describe safe handling, storage and transport requirements for full and empty cylinders
Your checkpoint
Cylinder fill-limit calculation worksheet with two worked examples and a hazard-to-control table covering four refrigerants
F-Gas and ODS Regulations - legal duties and environmental obligations & Installation, commissioning and record keeping & Service, maintenance and leak detection
Reconcile a set of service records against the legal record-keeping requirements and flag every gap
Trace a refrigerant charge from delivery through recovery and disposal across a full equipment lifecycle
Answer twenty mixed-domain practice questions under timed conditions
Write a short corrective action plan for the three weakest areas the practice test exposes
Your checkpoint
Completed audit of a mock record set with a written list of every deficiency and the corrective action for each
F-Gas and ODS Regulations - legal duties and environmental obligations & Refrigerant identification, properties and environmental impact & Installation, commissioning and record keeping & Service, maintenance and leak detection & Recovery, recycling, reclaim and disposal of refrigerant & Safety, handling and cylinder management
Complete two full-length timed mock exams and score each
Review every missed question and write the underlying rule or fact it tested
Re-test the weakest two domains until scores are stable across two attempts
Confirm the practical tasks (recovery, tightness testing, cylinder handling) can be described end to end without notes
Your checkpoint
Two scored mock exams with a one-page error log and a final readiness self-assessment per domain
Milestones
Week 2: Can state every legal threshold, duty holder and record type from memory and score 9/10 on the self-written legal quiz
Week 4: Can produce a compliant commissioning record and a leak-check schedule without referring to notes
Week 6: Can calculate cylinder fill limits and describe the full recovery-to-disposal path unaided
Week 8: Two timed mock exams scored, with all six domains at or above the pass threshold on the second attempt