ITI Solar Technician Electrical (AITT Theory) flashcards
ITI Solar Technician Electrical (AITT Theory) · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Ohm's law
- Voltage equals current multiplied by resistance (V = I × R). Used to calculate any one of the three quantities when the other two are known in a DC circuit.
- Power formula
- Electrical power P = V × I, also written P = I²R or P = V²/R. Measured in watts for DC and in watts of real power for AC.
- Series resistance
- In a series circuit the total resistance is the sum of individual resistances, the current is the same through every element, and voltages add.
- Parallel resistance
- In a parallel circuit the reciprocal of total resistance equals the sum of reciprocals of individual resistances; voltage is common and currents add.
- RMS value
- Root-mean-square value of a sine wave equals peak value divided by the square root of two. A 325 V peak corresponds to 230 V RMS.
- Power factor
- Cosine of the phase angle between voltage and current; equals R/Z. Real power equals apparent power multiplied by power factor.
- Clamp meter use
- Measures current by sensing the magnetic field around a conductor without breaking the circuit. Hall-effect versions can also measure DC current.
- Megohmmeter purpose
- Applies a high DC test voltage, typically 500 V or 1000 V, to measure insulation resistance in megohms and detect degraded cable or module insulation.
- Diode forward bias
- A silicon diode conducts when the anode is about 0.7 V more positive than the cathode; below this threshold it blocks current.
- Zener diode
- Operates in controlled reverse breakdown to hold a nearly constant voltage; a series resistor limits current and dissipates excess power.
- Bridge rectifier
- Four diodes arranged so both half-cycles of AC produce DC output of the same polarity; unfiltered output is about 0.9 times the RMS input.
- SCR latching
- A thyristor turns on with a gate pulse when forward biased and stays on until anode current falls below the holding current.
- IGBT use
- A voltage-controlled switch combining a MOSFET gate with bipolar conduction. It is the standard switching device in grid-tied PV inverters.
- Bypass diode role
- Connected across module sub-strings so that current can bypass a shaded or faulty cell, limiting hotspot heating and power loss.
- MCB function
- Miniature circuit breaker trips on overload by thermal action and on short circuit by magnetic action; rated breaking capacity is stated in kiloamperes.
- RCCB purpose
- Residual current circuit breaker, typically 30 mA, detects earth leakage and disconnects to protect people; it does not replace an MCB for overload protection.
- DC-rated devices
- Switches, fuses and breakers rated for direct current must be used on the PV array; AC-rated devices may arc and fail because DC has no zero crossing.
- Standard Test Conditions
- Reference conditions for module ratings: 1000 W/m² irradiance, 25 °C cell temperature and AM 1.5 spectrum. Nameplate power is measured here.
- Fill factor
- Ratio of maximum power to the product of open-circuit voltage and short-circuit current. Crystalline silicon modules typically show 0.70 to 0.80.
- Temperature effect on V_oc
- Open-circuit voltage falls roughly 0.3 % per °C as cell temperature rises, so cold mornings produce the highest string voltage.
- String voltage limit
- Series module voltages add. The string open-circuit voltage at the coldest expected temperature must stay below the inverter or controller maximum input voltage.
- Battery C-rate
- Discharge or charge current expressed as a multiple of capacity. C/10 means a full discharge takes ten hours; higher rates reduce usable capacity.
- MPPT controller
- Maximum power point tracker adjusts operating voltage to extract peak module power, typically at 95–98 % efficiency, and accepts higher array voltages.
- Anti-islanding
- Protection in grid-tied inverters that disconnects from the grid when grid supply is lost, preventing back-feed that endangers utility workers.
- Array sizing formula
- Array watt-peak equals daily energy demand divided by peak sun hours and system efficiency, where system efficiency typically ranges from 0.7 to 0.8.
- Battery bank sizing
- Capacity in Ah equals daily energy times autonomy days divided by depth of discharge, battery voltage and inverter efficiency, using consistent units.
- Performance ratio
- Actual annual energy divided by the energy the array would produce at rated efficiency under the same irradiance; typical values are 0.75 to 0.85.
- Insulation resistance test
- Measures resistance from live conductors to earth with a megohmmeter; values below about one megohm indicate moisture or damaged insulation needing investigation.
- Thermography
- Infrared imaging that reveals hotspots, loose terminations and failing bypass diodes by their abnormal temperature rise during operation.
- PV shock hazard
- Modules generate voltage whenever illuminated and cannot be switched off, so DC conductors must be treated as live until proven de-energised.
- Electrical fire extinguisher
- Carbon dioxide or dry powder extinguishers are used on live electrical fires; water conducts and must never be applied to energised equipment.
- Net metering
- A billing arrangement where the bi-directional meter records both import and export, and the consumer is billed on the net energy over the period.
- Single-line diagram
- A schematic showing the PV array, combiner, isolators, charge controller or inverter, battery, meter and earthing on one drawing using standard symbols.