Voltage (potential difference)

The electrical pressure that pushes charge between two points, measured in volts. One volt equals one joule of energy transferred per coulomb of charge moved through the circuit.

Related: Current, Resistance, Ohm's Law
Current

The rate at which electric charge flows past a point, measured in amperes. One ampere equals one coulomb of charge passing per second in a closed circuit.

Related: Voltage (potential difference), Ohm's Law
Resistance

The opposition a material offers to current flow, measured in ohms. It converts electrical energy into heat and depends on material, length, cross-sectional area and temperature.

Related: Ohm's Law, Voltage drop
Ohm's Law

The relationship stating that current through a conductor equals voltage across it divided by its resistance (I = V/R). It applies to linear resistive elements and underpins most circuit calculations.

Related: Voltage (potential difference), Resistance, Power (electrical)
Power (electrical)

The rate at which electrical energy is transferred or consumed, measured in watts. In DC circuits it equals voltage multiplied by current; in AC circuits the power factor also applies.

Related: Ohm's Law, Power factor, Energy (kWh)
Energy (kWh)

The total electrical work delivered over time, usually billed in kilowatt-hours. One kilowatt-hour equals one kilowatt of power sustained for one hour, equivalent to 3.6 megajoules.

Related: Power (electrical), Load profile
Series and parallel connection

Series wiring joins components end to end so the same current passes through all, adding voltages. Parallel wiring connects them across the same nodes, so voltage is shared and currents add.

Related: Kirchhoff's laws, String
Kirchhoff's laws

Two rules for circuit analysis: current entering a junction equals current leaving it, and the sum of voltage changes around any closed loop is zero. They apply to any network.

Related: Series and parallel connection, Voltage drop
Alternating current (AC)

Current that reverses direction periodically, typically 50 Hz in India. Its magnitude and direction follow a sine wave, and its effective heating value is given by the RMS figure.

Related: RMS value, Power factor, Inverter
RMS value

The root-mean-square value of an alternating quantity, equal to the steady DC value that would produce the same heating effect. For a pure sine wave it is peak value divided by 1.414.

Related: Alternating current (AC), Multimeter
Power factor

The ratio of real power in watts to apparent power in volt-amperes in an AC circuit. It equals the cosine of the phase angle between voltage and current, ranging from zero to one.

Related: Power (electrical), Alternating current (AC), Inverter
Voltage drop

The reduction in voltage along a conductor or component caused by its resistance and current. Excessive drop in cables wastes energy and can cause equipment malfunction or nuisance tripping.

Related: Resistance, Cable sizing
Multimeter

A handheld instrument combining voltmeter, ammeter and ohmmeter functions, often with continuity and diode tests. It is the basic tool for commissioning checks and fault finding on PV systems.

Related: Clamp meter, Insulation resistance tester, RMS value
Clamp meter

An instrument that measures current by surrounding a conductor with a magnetic jaw, without breaking the circuit. Many models also measure DC current, which is useful for battery and string checks.

Related: Multimeter, Current
Insulation resistance tester

A megohmmeter that applies a high test voltage to measure leakage through insulation, reported in megohms. It verifies cable and module insulation integrity before energising a PV installation.

Related: Earthing (grounding), Multimeter
Diode

A two-terminal semiconductor that conducts readily in one direction and blocks the reverse. It is used for rectification, reverse-current blocking and bypass functions in photovoltaic modules.

Related: Bypass diode, Blocking diode, Rectifier
Bypass diode

A diode connected across a group of solar cells, or across a module, to provide an alternate current path when cells are shaded or faulty. It limits hot-spot heating and preserves string output.

Related: Diode, Hot spot, Blocking diode
Blocking diode

A diode placed in series with a PV string or module to prevent reverse current from batteries or parallel strings flowing back through it during darkness or shading.

Related: Diode, Bypass diode, Charge controller
Rectifier

A circuit of diodes that converts alternating current into pulsating direct current. Bridge rectifiers are common in equipment power supplies and in some inverter front ends.

Related: Diode, Inverter
Transistor (IGBT/MOSFET)

A semiconductor switch controlled by an electrical signal, used to switch power rapidly in inverters and converters. MOSFETs suit high-frequency low-voltage work; IGBTs suit higher-power applications.

Related: Inverter, Pulse-width modulation (PWM), Maximum power point tracking (MPPT)
Pulse-width modulation (PWM)

A switching technique that varies the on-time proportion of a fixed-frequency square wave to control average output voltage. It is used in charge controllers, inverters and motor drives.

Related: Transistor (IGBT/MOSFET), PWM charge controller, Inverter
Standard Test Conditions (STC)

The reference conditions for rating PV modules: irradiance of 1000 W/m², cell temperature of 25 °C and air mass 1.5 spectrum. Nameplate wattage is quoted at these conditions.

Related: Irradiance, Temperature coefficient, Peak sun hours
Irradiance

The instantaneous solar power density falling on a surface, measured in watts per square metre. It varies through the day and with clouds, haze and the angle of the sun.

Related: Standard Test Conditions (STC), Peak sun hours, Tilt angle
Peak sun hours

The daily solar energy received expressed as the number of hours at 1000 W/m² that would deliver the same energy. It is used to estimate daily generation per kilowatt-peak.

Related: Irradiance, Performance ratio, Energy yield
Open-circuit voltage (Voc)

The voltage measured across a PV module or string with no load connected, at its highest for a given temperature. It falls as cell temperature rises and sets the maximum system voltage.

Related: Short-circuit current (Isc), Temperature coefficient, String
Short-circuit current (Isc)

The current that flows when module terminals are directly connected through an ammeter of near-zero resistance. It is the highest current the module can produce at a given irradiance.

Related: Open-circuit voltage (Voc), Maximum power point (MPP)
Maximum power point (MPP)

The operating point on a PV device's current-voltage curve where the product of voltage and current is greatest. Trackers continuously adjust the load to stay at this point.

Related: Maximum power point tracking (MPPT), Fill factor, Short-circuit current (Isc)
Fill factor

The ratio of a module's maximum power to the product of its open-circuit voltage and short-circuit current. A higher fill factor indicates a better-quality cell with lower series losses.

Related: Maximum power point (MPP), Open-circuit voltage (Voc)
Temperature coefficient

The percentage change in a PV parameter, usually power or voltage, for each degree Celsius rise in cell temperature. It is negative for power and voltage, so hot modules produce less.

Related: Standard Test Conditions (STC), Open-circuit voltage (Voc)
String

A number of PV modules connected in series to build up the required DC voltage. Modules in a string carry the same current, so mismatched or shaded modules reduce the whole string's output.

Related: Series and parallel connection, Bypass diode, Maximum power point tracking (MPPT)
Hot spot

A localised overheated area on a module caused by a shaded, cracked or mismatched cell dissipating power instead of generating it. Bypass diodes and good installation practice limit damage.

Related: Bypass diode, Shading analysis
Shading analysis

The study of how nearby objects such as trees, buildings and poles cast shadows on a PV array through the year. It identifies shading losses and guides array placement and string layout.

Related: Hot spot, Tilt angle, String
Tilt angle

The angle at which a PV module is inclined from the horizontal. It is usually chosen near the site latitude to maximise annual yield, or steeper to favour winter generation.

Related: Irradiance, Shading analysis
Charge controller

A device between PV array and battery that regulates charging voltage and current to prevent overcharge and often over-discharge. PWM and MPPT types differ in how they handle array voltage.

Related: PWM charge controller, Maximum power point tracking (MPPT), Depth of discharge (DoD)
Maximum power point tracking (MPPT)

An electronic control method that continuously adjusts the operating voltage of a PV array to extract maximum power under changing irradiance and temperature. It raises yield especially in cold or variable conditions.

Related: Maximum power point (MPP), Charge controller, Inverter
Depth of discharge (DoD)

The proportion of a battery's rated capacity that has been withdrawn, expressed as a percentage. Limiting DoD extends cycle life, particularly for lead-acid batteries.

Related: State of charge (SoC), Battery capacity (Ah)
State of charge (SoC)

The remaining stored energy in a battery expressed as a percentage of its full capacity. It is estimated from voltage, current integration or specific gravity in flooded lead-acid cells.

Related: Depth of discharge (DoD), Battery capacity (Ah)
Inverter

A device that converts direct current from a PV array or battery into alternating current suitable for appliances or the grid. Off-grid inverters may also incorporate chargers and transfer switches.

Related: Power factor, Anti-islanding, Net metering
Anti-islanding

A protective function that stops a grid-connected inverter from energising a line after the utility supply fails. It protects utility workers and prevents out-of-phase reconnection hazards.

Related: Inverter, Net metering, Islanding
Net metering

A billing arrangement in which exported solar energy is credited against imported grid energy, typically through a bidirectional meter. The consumer pays for the net difference over the billing period.

Related: Bidirectional meter, Anti-islanding, Grid interconnection
Earthing (grounding)

Deliberate connection of exposed metalwork and circuit points to the earth through a low-resistance path. It limits touch voltage during faults and gives protection devices a return path to operate.

Related: Insulation resistance tester, Residual current device (RCD), Lightning arrester
Residual current device (RCD)

A protective switch that trips when the current difference between live and neutral conductors exceeds a set threshold, indicating leakage to earth. It protects people from electric shock.

Related: Earthing (grounding), Miniature circuit breaker (MCB)
Miniature circuit breaker (MCB)

A resettable automatic switch that opens on overload or short circuit, protecting cables and equipment. Its rating and trip curve must be coordinated with cable current-carrying capacity.

Related: Cable sizing, Residual current device (RCD)
Cable sizing

Selecting conductor cross-section so it safely carries expected current while keeping voltage drop and temperature rise within limits. It considers derating for ambient temperature and grouping.

Related: Voltage drop, Miniature circuit breaker (MCB)
Performance ratio

The ratio of a plant's actual energy output to the output it would produce at rated efficiency under the same irradiance. It captures losses from temperature, soiling, wiring and inverter conversion.

Related: Energy yield, Peak sun hours, Soiling
Energy yield

The electrical energy a PV system delivers over a period, usually expressed in kilowatt-hours per installed kilowatt-peak. It depends on irradiance, tilt, losses and system availability.

Related: Performance ratio, Peak sun hours, Load profile
Load profile

A record of how much power a site consumes over time, showing daily and seasonal variation. It guides battery sizing, inverter rating and decisions about grid or generator backup.

Related: Energy (kWh), Energy yield, Battery capacity (Ah)
Battery capacity (Ah)

The charge a battery can store, quoted in ampere-hours at a specified discharge rate. Multiplying by nominal voltage gives watt-hours, which is more useful for system sizing.

Related: Depth of discharge (DoD), State of charge (SoC), Load profile
Current-voltage (I-V) curve

A plot of a PV device's output current against voltage across its operating range. Its shape reveals series resistance, shunt losses and the maximum power point used for performance checks.

Related: Maximum power point (MPP), Fill factor, Open-circuit voltage (Voc)
Islanding

The condition in which a grid-connected inverter keeps supplying a local circuit after the utility supply has been disconnected. Anti-islanding protection is required to prevent it.

Related: Anti-islanding, Grid interconnection