Ohm's Law

The fixed relationship among voltage, current, and resistance in a circuit, expressed as voltage equals current multiplied by resistance. Inspectors use it to verify that measured current and voltage are consistent with expected conductor loading.

Related: Voltage Drop, Ampacity
Impedance

The total opposition a circuit presents to alternating current, combining resistance with inductive and capacitive reactance. It governs actual current flow in AC systems and matters when sizing conductors and evaluating equipment performance.

Related: Power Factor, Voltage Drop
Power Factor

The ratio of real power to apparent power in an AC circuit, reflecting how much supplied current performs useful work. Low power factor increases current for the same load, affecting conductor and equipment sizing calculations.

Related: Impedance, Load Calculation
Voltage Drop

The reduction in voltage along conductors caused by their resistance and reactance under load. Branch-circuit and feeder runs are checked so delivered voltage stays adequate for connected equipment to operate properly.

Related: Ohm's Law, Ampacity
Ampacity

The maximum current a conductor can carry continuously under specified conditions without exceeding its temperature rating. It depends on conductor material, size, insulation type, ambient temperature, and number of current-carrying conductors.

Related: Conductor Derating, Overcurrent Protective Device
Conductor Derating

The required adjustment of a conductor's tabulated ampacity for conditions such as elevated ambient temperature or multiple current-carrying conductors bundled together. Derating prevents insulation damage from accumulated heat.

Related: Ampacity, Raceway Fill
Raceway Fill

The proportion of a raceway's cross-sectional area occupied by conductors and cables. Limits exist so conductors can be installed without damage and heat can dissipate adequately.

Related: Conductor Derating, Ampacity
Continuous Load

A load expected to operate at maximum current for three hours or more. Branch circuits and feeders serving continuous loads are sized with additional capacity beyond the calculated load.

Related: Load Calculation, Overcurrent Protective Device
Load Calculation

A structured method of summing connected loads, applying demand factors, and determining the minimum service, feeder, and branch-circuit capacity required for a building. Results drive conductor and equipment selection.

Related: Demand Factor, Continuous Load
Demand Factor

A ratio applied to connected load to account for the fact that not all loads operate simultaneously at full capacity. It permits smaller service and feeder sizing than the total connected load would require.

Related: Load Calculation, Service Entrance Conductors
Service Entrance Conductors

The conductors that carry power from the utility supply point to the service equipment disconnecting means. Their size is based on the calculated load and must coordinate with the service overcurrent protection.

Related: Load Calculation, Overcurrent Protective Device
Grounding Electrode System

The set of conductive elements, such as rods, pipes, or concrete-encased electrodes, that establishes a deliberate connection between the electrical system and the earth. It provides a reference potential and a path for certain fault and surge currents.

Related: Equipment Grounding Conductor, Bonding Jumper
Equipment Grounding Conductor

The conductor that connects normally non-current-carrying metal parts of equipment to the system grounding point. It provides a low-impedance fault path so overcurrent protection operates promptly.

Related: Grounding Electrode System, Overcurrent Protective Device
Bonding Jumper

A conductor that ensures electrical continuity between metal parts required to be electrically connected. Bonding equalizes potential and prevents dangerous voltage differences between adjacent metallic systems.

Related: Grounding Electrode System, Equipment Grounding Conductor
Overcurrent Protective Device

A fuse or circuit breaker designed to open a circuit automatically when current exceeds a safe level. Selection considers conductor ampacity, equipment ratings, and the type of fault current available.

Related: Ampacity, Interrupting Rating
Interrupting Rating

The maximum fault current a protective device is rated to safely interrupt without damage or hazard. The device's rating must equal or exceed the available fault current at its installation point.

Related: Overcurrent Protective Device, Available Fault Current
Available Fault Current

The maximum short-circuit current the supply system can deliver at a given point in the installation. It is compared against equipment ratings to confirm the equipment can withstand a fault.

Related: Interrupting Rating, Overcurrent Protective Device
Ground-Fault Circuit Interrupter

A device that detects small current imbalances between the ungrounded and grounded conductors and opens the circuit quickly. It protects people from shock in wet or otherwise hazardous locations.

Related: Equipment Grounding Conductor, Overcurrent Protective Device
Arc-Fault Circuit Interrupter

A protective device that senses characteristic arcing signatures in branch-circuit wiring and de-energizes the circuit. It addresses fire risk from damaged or deteriorated conductors.

Related: Overcurrent Protective Device, Ground-Fault Circuit Interrupter
Box Fill

The calculated volume of a box required to accommodate conductors, devices, fittings, and grounding conductors. Adequate volume prevents insulation damage and overheating at splices.

Related: Raceway Fill, Conductor Derating
Working Space

The clear area in front of electrical equipment that must remain unobstructed so qualified persons can safely service the equipment. Depth and width depend on voltage and equipment conditions.

Related: Arc Flash, Equipment Labeling
Arc Flash

A sudden release of energy caused by an electrical arc between conductors or to ground, producing intense heat, light, and pressure. Inspection includes verifying labeling and safe working distances.

Related: Working Space, Equipment Labeling
Equipment Labeling

Markings applied to electrical equipment identifying ratings, circuit sources, and required safety information. Labels support safe operation, maintenance, and inspection verification.

Related: Working Space, Arc Flash
Approved

Accepted by the authority having jurisdiction as meeting applicable codes and standards, often demonstrated by listing or field evaluation. Inspectors rely on this status when accepting equipment and materials.

Related: Authority Having Jurisdiction, Listing
Listing

The formal recognition by a qualified testing organization that a product meets designated safety standards. Listed equipment carries a mark indicating third-party evaluation.

Related: Approved, Authority Having Jurisdiction
Authority Having Jurisdiction

The organization or individual responsible for enforcing code requirements and approving equipment, materials, and installations. The inspector works under or as this authority and documents decisions accordingly.

Related: Approved, Plan Review
Plan Review

The pre-construction examination of drawings and specifications for compliance with code requirements. It identifies deficiencies before installation, reducing field corrections and rework.

Related: Authority Having Jurisdiction, Correction Notice
Correction Notice

A written record identifying code deficiencies found during inspection and specifying required corrective action. It documents the finding, the code basis, and the re-inspection outcome.

Related: Plan Review, Authority Having Jurisdiction
Inspection Record

The documented account of an inspection, including date, scope, observed conditions, code references, and disposition. Clear records support enforcement and demonstrate professional diligence.

Related: Correction Notice, Plan Review
Hazardous Location Classification

The system of designating areas by the likelihood and duration of flammable gases, vapors, dusts, or fibers. Classification determines permitted wiring methods and equipment construction.

Related: Intrinsically Safe Circuit, Explosionproof Equipment
Explosionproof Equipment

Enclosures designed to contain an internal ignition and prevent ignition of the surrounding flammable atmosphere. They rely on flame paths and temperature limits, not on excluding gases entirely.

Related: Hazardous Location Classification, Intrinsically Safe Circuit
Intrinsically Safe Circuit

A circuit in which energy is limited so that sparks or thermal effects cannot ignite a flammable atmosphere under normal or specified fault conditions. It typically requires associated apparatus and control drawings.

Related: Hazardous Location Classification, Explosionproof Equipment
Class I Location

An area where flammable gases or vapors are or may be present in quantities sufficient to produce ignitable mixtures. Divisions or zones further describe the likelihood of presence.

Related: Hazardous Location Classification, Explosionproof Equipment
Negligence

Failure to exercise the degree of care a reasonable professional would exercise under similar circumstances. For inspectors, it can arise from missed code violations or inadequate documentation.

Related: Standard of Care, Conflict of Interest
Standard of Care

The level of diligence and competence expected of a similarly situated professional inspector. It frames judgments about whether an inspection met accepted practice.

Related: Negligence, Inspection Record
Conflict of Interest

A situation in which an inspector's personal, financial, or other interest could improperly influence professional judgment. Disclosure and recusal protect objectivity and public trust.

Related: Standard of Care, Code Enforcement
Code Enforcement

The process of applying adopted electrical code requirements consistently through review, inspection, and corrective action. It requires impartiality, accurate citations, and fair treatment of all parties.

Related: Authority Having Jurisdiction, Conflict of Interest