MA General Contractor study materials
MA General Contractor study resources

MA General Contractor cheat sheet

MA General Contractor · Keep the key ideas within reach.

Quick reference

Massachusetts Building Code

  • 780 CMR is the Massachusetts State Building Code; it adopts the International Building Code with Massachusetts amendments and applies statewide.

  • The Board of Building Regulations and Standards (BBRS) adopts and amends 780 CMR; local building inspectors enforce it day to day.

  • One- and two-family dwellings are designed under the code's residential provisions, which include prescriptive tables for spans, egress, and energy.

  • Decisions of a local building official may be appealed to the state Building Code Appeals Board, generally within 30 days of the decision.

  • 521 CMR, the Architectural Access Board regulations, governs accessibility in public and commercial buildings and is enforced in addition to the building code.

  • Work on existing buildings is classified as repair, renovation, alteration, addition, or change of use; a change of use or substantial alteration can trigger upgrade requirements.

  • Occupancy group (A, B, E, R, M, S, F, U) and construction type set allowable height and area from the code tables.

  • Where the code and a manufacturer's listed instructions differ, the more restrictive requirement governs, and listed assemblies must be installed per their listing.

  • Energy requirements sit in 225 CMR 22 for residential and 225 CMR 23 for commercial work, with a stricter Stretch Code for Green Communities.

Quick reference

Permitting and Inspection

  • The building official must grant or deny a permit application within 30 days for one- and two-family dwellings and within 45 days for all other buildings.

  • Building permits lapse when work has not commenced within six months or has been suspended for a continuous six months; local ordinances set the exact period.

  • Standard inspection points: excavation and footing before concrete, foundation and waterproofing before backfill, framing and rough-in before insulation, final at completion.

  • Separate permits and separate inspectors apply to electrical, plumbing, gas fitting, and sheet metal work.

  • A certificate of occupancy is required before a new building is occupied or an existing building changes use; a conditional temporary certificate may be issued.

  • Zoning relief runs through the local board of appeals: appeals within 20 days, and variances or special permits require a public hearing and a filed written decision.

  • Work in or near wetlands or floodplains requires a Notice of Intent to the Conservation Commission and an Order of Conditions before soil is disturbed.

  • Septic systems and wells require local Board of Health approval under Title 5 (310 CMR 15.000) before or together with the building permit.

  • The permit and approved plans must remain on site; a stop-work order halts all work until the cited condition is corrected and released.

Quick reference

Contract Law

  • A valid contract requires offer, acceptance, consideration, capacity, and a lawful purpose.

  • Contracts that cannot be performed within one year must be in writing under the statute of frauds; change orders should be written and signed before work proceeds.

  • M.G.L. c. 93A prohibits unfair or deceptive acts in trade or commerce; a written demand letter must be sent at least 30 days before filing suit.

  • Home improvement contracts must be written, show the contractor's HIC registration number, and give the homeowner a three-business-day cancellation right when signed at the home.

  • Massachusetts recognizes an implied warranty of good and workmanlike construction, independent of any express written warranty.

  • Contract documents should define scope, price, payment schedule, retainage, schedule, change-order procedure, warranty, insurance, indemnity, and termination.

  • Progress payments should be tied to executed conditional lien waivers so releases match money actually received.

  • Time-is-of-the-essence clauses, liquidated damages, and no-damages-for-delay clauses are enforceable but strictly construed against the drafter.

  • Dispute resolution clauses set the forum (mediation, arbitration, court venue); arbitration is not required unless the parties agreed to it.

Quick reference

Liens and Business Practices

  • M.G.L. c. 254 governs mechanic's liens; the lien is generally recorded in the registry of deeds within 90 days after the last day labor or materials were furnished.

  • A subcontractor perfects a lien by recording a Notice of Contract and later a Statement of Account; the general contractor's contract with the owner is the lien basis.

  • A civil action to enforce the lien must be commenced within 90 days after recording the statement of account, or the lien dissolves.

  • On owner-occupied one- to four-family homes, subcontractors and suppliers have limited lien rights unless the owner authorized or consented to the work in writing.

  • Massachusetts applies a strict three-part (ABC) test for independent contractor status: freedom from control, work outside the usual course of business, and an independently established trade.

  • Workers' compensation insurance is mandatory for any employer with at least one employee; collect certificates of insurance from every subcontractor before mobilization.

  • Home Improvement Contractor (HIC) registration is required for residential remodeling; an unregistered contractor cannot enforce the contract and faces fines.

  • The Home Improvement Guaranty Fund can reimburse homeowners for losses caused by registered contractors, subject to statutory claim limits.

  • Retain contracts, change orders, permits, payroll records, and insurance certificates for at least six years, matching the contract statute of limitations.

Quick reference

Plan Reading

  • Sheet order commonly runs general (G), civil (C), architectural (A), structural (S), mechanical (M), electrical (E), plumbing (P).

  • At 1/4 in = 1 ft, one quarter inch on paper equals twelve inches in reality; confirm with the graphic scale whenever a sheet has been reduced or enlarged.

  • Plans give width and length, sections give height and assembly, elevations give exterior appearance; cross-check all three before layout.

  • Grid and column lines anchor dimensions and details; dimension strings are read to the nearest structural or finish face they reference.

  • Door and window schedules key by mark (D-3, W-5) and list size, type, glazing, fire rating, and hardware.

  • Detail callouts show detail number over sheet number (5/A-501); section marks show the cut location and direction of view.

  • Revision clouds and deltas flag changes; the latest revision date and the issued-for-construction stamp govern the work.

  • Elevation datum is often set at the first floor; confirm whether dimensions run to structural or finish surfaces.

  • Site plans show property lines, setbacks, benchmark, utilities, flood zone, north arrow, and erosion and sedimentation controls.

Quick reference

Estimating and Project Layout

  • Board feet = thickness in inches times width in inches times length in feet, divided by 12.

  • Concrete cubic yards = length times width times depth, all in feet, divided by 27; add 5 to 10 percent for waste and over-excavation.

  • Gross margin = markup divided by (1 + markup); a 20 percent markup on cost produces only a 16.7 percent margin on price.

  • Takeoff follows construction sequence: excavation, concrete, masonry, framing and lumber, envelope, MEP rough-in, insulation, finishes.

  • Typical waste factors: framing lumber 5 to 10 percent, roofing shingles 10 percent plus starter and ridge, drywall and tile 10 to 15 percent.

  • Square a layout with the 3-4-5 triangle or by comparing diagonals; equal diagonals confirm a true rectangle.

  • Set batter boards and string lines outside the excavation limits so stakes survive digging, and transfer the benchmark to a protected point.

  • A story pole marked with floor-to-floor heights, plate heights, and window head heights keeps elevations consistent across the crew.

  • Percent slope equals rise divided by run times 100; a 4:12 roof pitch is a 33 percent slope.

Quick reference

Site Work, Excavation and Foundations

  • Massachusetts law requires notifying Dig Safe (811) at least 72 hours before excavation and waiting for utility marks before digging.

  • OSHA 1926 Subpart P requires a protective system at 5 ft depth in trenches; excavations 20 ft or deeper need a registered professional engineer's design.

  • Provide a ladder, stair, or ramp within 25 ft of lateral travel in any trench 4 ft or deeper.

  • Spoil and equipment stay at least 2 ft back from the excavation edge, and a competent person inspects daily and after rain.

  • Footings bear on undisturbed soil below the frost line, roughly 42 to 48 in in Massachusetts, and at least 12 in below finished grade.

  • Erosion control before grading: silt fence on the downslope perimeter, stabilized construction entrance, and inlet protection.

  • Backfill in lifts of about 8 to 12 in, compact to the specified density (commonly 95 percent standard Proctor), and protect foundation drains.

  • Confirm bearing capacity and footing size from the soils report or code tables; a proof roll reveals unsuitable subgrade.

  • Work in wetlands requires a Notice of Intent to the Conservation Commission and an Order of Conditions before any soil disturbance.

Quick reference

Concrete and Masonry Construction

  • Specified strength f'c is verified on 28-day cylinder breaks; the mix water-cement ratio controls both strength and durability.

  • Slump per ASTM C143 measures workability; adding water on site raises the water-cement ratio and lowers strength.

  • Vibration consolidates concrete; over-vibration causes segregation. Screed, float, and cure to limit plastic shrinkage cracks.

  • Cure concrete moist for at least 7 days; vertical forms may come off after 24 to 48 hours, structural forms only after strength is verified.

  • Reinforcement cover is about 3 in where cast against earth and 1.5 to 2 in on exposed formed surfaces.

  • Standard concrete masonry units are 8 by 8 by 16 in nominal; mortar joints are typically 3/8 in and are tooled when thumbprint hard.

  • Masonry veneer requires a drainage plane, base flashing, and weep holes spaced not more than 24 in on center above the flashing.

  • Grout lifts are limited in height and must be puddled to fill cells completely; reinforcement is positioned and inspected before grouting.

  • Control and expansion joints accommodate movement; place brick expansion joints at corners, offsets, and intervals set by code to prevent random cracking.

Quick reference

Carpentry and Structural Framing

  • Notches at joist ends may not exceed one quarter of the depth; notches elsewhere may not exceed one sixth of the depth.

  • Holes may not exceed one third of the joist depth, must be at least 2 in from the top and bottom edges, and belong in the outer thirds of the span.

  • Bearing is at least 1-1/2 in on wood or metal and at least 3 in on masonry, with mechanical connection to prevent rotation.

  • Match span tables to species, grade, size, spacing, and live load; verify the grade stamp or use an engineered design.

  • Studs run 16 or 24 in on center; openings need a table-sized header plus king and jack studs, with a sill at windows.

  • Lay out from one reference line, crown joists upward, and install solid blocking at bearings and over supports.

  • Subfloor panels run long dimension across joists with 1/8 in edge gaps, glued and nailed per schedule, and staggered end joints.

  • Trusses may not be cut, notched, or field-modified without a registered engineer's approval; install temporary and permanent bracing per the truss design.

  • Fire blocking is required in concealed spaces between floors, at soffits and dropped ceilings, and around penetrations through top plates.

Quick reference

Roofing, Waterproofing and Exterior Finishes

  • Asphalt shingles need a 4:12 minimum for standard application; 2:12 to 4:12 requires double underlayment, and below 2:12 a membrane roof is required.

  • Ice barrier membrane runs along the eaves from the roof edge to at least 24 in inside the interior wall line, and through valleys in cold climates.

  • Drip edge goes under the underlayment at eaves and over it at rakes; underlayment laps shingle-style with upper sheets over lower.

  • Flashings: step flashing at sidewalls, kick-out flashing where a roof meets a wall, pan flashing at decks and chimneys.

  • Fasten shingles with 6 nails in high-wind zones, driven above the exposure line through the nailing strip; 4 nails is the minimum elsewhere.

  • Weather-resistive barrier is installed shingle-lap over the framing with sealed penetrations, and siding is held at least 6 to 8 in above grade.

  • Window flashing sequence: sill pan first, then jambs, then head; back-dam the sill and integrate the assembly with the water-resistive barrier.

  • Attic ventilation: about 1 sq ft of net free vent area per 150 sq ft of ceiling, or 1/300 when vents are balanced and a vapor retarder is present.

  • Decks and porches need a flashed ledger, corrosion-resistant fasteners, and positive slope of walking surfaces away from the house.

Quick reference

Energy Code and Building Envelope Performance

  • 225 CMR 22 covers residential and 225 CMR 23 covers commercial energy performance; both adopt the IECC with Massachusetts amendments.

  • Climate zone 5 prescriptive values commonly used: ceiling R-49, wood-frame wall R-20 or R-13 plus 5 continuous, basement wall R-15/19, slab R-10, windows U-0.30.

  • Air leakage is verified by a blower-door test measured in air changes per hour at 50 pascals; the Stretch Code threshold is stricter than the base code.

  • Insulation must stay in continuous contact with the air barrier without gaps or compression, and eave baffles must preserve attic vent space.

  • Ducts and air handlers located in unconditioned space must be sealed and insulated, and duct leakage testing may be required.

  • Recessed luminaires penetrating the envelope must be insulation-contact rated and air-sealed to keep the barrier continuous.

  • Windows and doors must carry NFRC labels showing U-factor and solar heat gain coefficient that meet or beat the scheduled values.

  • Tight envelopes require whole-house mechanical ventilation, typically an exhaust or balanced HRV/ERV system meeting ASHRAE 62.2.

  • A compliance report or HERS certificate must be posted at the job and given to the owner at completion.

Quick reference

Jobsite Safety and Regulatory Compliance

  • OSHA 29 CFR 1926 governs construction; fall protection is required at 6 ft, with top rails at 42 in plus or minus 3 in and midrails at 21 in.

  • Extension ladders are set at a 4:1 slope, extend 3 ft above the landing, and are secured at the top.

  • Scaffolds must be fully planked with guardrails on all open sides and tied to the structure when height exceeds four times the base width.

  • Trenches need a protective system at 5 ft, access within 25 ft of travel, spoil 2 ft back, and daily competent-person inspection.

  • All 120-volt, 15- and 20-ampere receptacles on site require GFCI protection or an assured equipment grounding conductor program.

  • Silica exposure from cutting masonry or concrete is controlled with water or vacuum dust collection and Table 1 respiratory protection.

  • Massachusetts requires workers' compensation insurance for any employer with one or more employees, with proof posted on site.

  • Housekeeping and access: keep walkways clear, cover or guard floor openings, and keep material stacked back from edges.

  • Hazard communication requires safety data sheets on site, labeled containers, and PPE selected from the hazard assessment.

Quick reference

Coordination of Electrical, Plumbing and Mechanical Trades

  • Sequence plumbing, electrical, and HVAC rough-in before the framing inspection and insulation; each trade pulls its own permit and gets its own inspection.

  • GFCI protection is required in kitchens, bathrooms, garages, outdoors, and within 6 ft of sinks; AFCI protection covers most dwelling branch circuits.

  • Electrical panel working clearance is 30 in wide, 36 in deep, and 6 ft 6 in high, kept free of storage.

  • Box fill is limited by conductor count and device size under NEC 314.16; overfilled boxes are a common inspection failure.

  • Smoke alarms are interconnected in each bedroom, outside sleeping areas, and on every level; CO alarms go near sleeping areas where fuel-fired appliances exist.

  • Drain waste and vent pipe 3 in and smaller slopes 1/4 in per ft, and vents must terminate the code-required distance above and from roof openings.

  • Water heater temperature and pressure relief discharge must run full size by gravity to a safe location with no trap, valve, or reduction.

  • HVAC sizing uses Manual J and duct design uses Manual D; seal ducts and provide combustion air plus condensate drainage.

  • Firestopping is required where pipes, ducts, and cables penetrate rated assemblies, so sleeves and blocking must be coordinated with the framing layout.