MN Asbestos Abatement study materials
MN Asbestos Abatement study resources

MN Asbestos Abatement cheat sheet

MN Asbestos Abatement · Keep the key ideas within reach.

Quick reference

Asbestos Licensing (Minnesota)

  • Minnesota asbestos abatement work is regulated by the Department of Health (MDH) under Minn. Stat. ch. 326 and Minn. R. ch. 4620; contractors, supervisors, workers, and project designers each hold separate license or certification categories.

  • A licensed asbestos abatement contractor must hold a current Minnesota license before submitting a notification or starting work; bidding or contracting for abatement without the license is prohibited.

  • Individuals must complete an MDH-approved initial course (contractor/supervisor 40-hour, worker 32-hour, project designer 24-hour, plus inspector/management planner courses) and pass the course exam to apply for certification.

  • Annual refresher training is required for continued certification: supervisor/contractor refreshers are typically 8 hours, worker refreshers 4 hours; the refresher must be completed within the 12 months before the certificate expires.

  • Certificates are renewed on a yearly cycle; lapse requires retaking the full initial course rather than only a refresher in most cases.

  • License/certification numbers must appear on notifications, contracts, and project records; a copy of the certificate must be available on site during abatement.

  • Firms must carry the liability insurance and bonding required by MDH rule, and must report changes in ownership, name, or qualifying person to the agency.

  • Violations can result in license suspension/revocation, civil penalties, and stop-work orders; unlicensed abatement is a misdemeanor-level offense under state law.

Quick reference

Work Practices

  • Regulated abatement areas must be enclosed with critical barriers and negative pressure; a minimum of 4 air changes per hour and a pressure differential of about -0.02 inches of water column is the standard target.

  • Wet methods are required: saturate ACM before and during removal, keep it wet through bagging, and never dry-sweep, dry-scrape, or use compressed air on asbestos-containing debris.

  • Use glove bags for small-scale removal on pipe/duct runs; the bag must be sealed to the pipe, tools kept inside, and waste goosenecked into a labeled disposal bag.

  • Waste must be double-bagged in 6-mil leak-tight bags or wrapped in 6-mil poly and labeled with the required asbestos warning; sharps go in rigid containers.

  • Decontamination units use a three-stage sequence: equipment room, shower, clean room; workers pass through the shower before leaving the work area.

  • Final clearance requires visual inspection showing no residue, then aggressive air sampling (or approved alternative) with fiber counts at or below the clearance limit before reoccupancy.

  • HEPA vacuums and negative air machines must be used; exhaust from negative air units should be HEPA-filtered and discharged outside the containment.

  • Personal air monitoring and respirator use follow the OSHA construction standard (29 CFR 1926.1101), including medical surveillance and fit testing.

Quick reference

Products Containing Asbestos

  • Asbestos was used in hundreds of building products; common categories include thermal system insulation, surfacing materials (spray-applied fireproofing, acoustical plaster), and miscellaneous materials (floor tile, mastic, roofing, cement board).

  • Friable means material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry; non-friable materials can become friable through damage, sanding, or demolition.

  • Category I non-friable includes asphalt roofing, flooring, and gaskets; Category II includes cementitious products such as transite, cement pipe, and shingles.

  • Presumed asbestos-containing material (PACM) includes thermal system insulation and surfacing materials in buildings constructed before the cutoff date unless sampling proves otherwise.

  • Chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite are the six regulated asbestos minerals; only chrysotile is serpentine, the rest are amphiboles.

  • Bulk sampling requires a accredited inspector, proper sampling protocol (typically a minimum number of samples per homogeneous area), and laboratory analysis by PLM or TEM.

  • Asbestos-containing material is generally defined as containing more than 1% asbestos by weight under the applicable standard; some rules apply to any detectable amount.

  • Suspect materials must be assumed ACM until sampled and confirmed by an accredited inspector and accredited laboratory.

Quick reference

Schools (AHERA)

  • AHERA (40 CFR Part 763, Subpart E) applies to all public and private K-12 schools, including charter and religious schools, regardless of building age.

  • Each school must designate an AHERA designated person, conduct an initial inspection by an accredited inspector, and develop a management plan within the required timeline.

  • Management plans must be available at the school and at the local education agency, and must be updated annually and re-inspected every three years by an accredited inspector.

  • Schools must notify parents, teachers, and employee organizations annually about the plan and about abatement or response actions planned or in progress.

  • Response actions include repair, encapsulation, enclosure, removal, and operations and maintenance (O&M); O&M is appropriate where material is in good condition and not disturbed.

  • Abatement in schools must be performed by accredited personnel with 10-working-day prior notification to the state and EPA; emergency projects allow shorter notice.

  • Clearance after abatement in a school requires visual inspection and air sampling with results at or below 0.01 fibers per cubic centimeter (f/cc) by PCM before reoccupancy.

  • Records of inspections, sampling, response actions, and training must be retained for the periods specified in the rule (commonly at least three years, with some records kept longer).