NABCEP SHI key terms
NABCEP SHI · Get comfortable with the vocabulary.
- Fall protection
- Related: Lockout/tagout
Systems and practices that prevent a worker from falling from a roof or elevated platform, such as guardrails, personal fall-arrest harnesses, and anchor points, plus the training and inspection needed to use them correctly.
- Lockout/tagout
- Related: Fall protection, Pressure test
A safety procedure that isolates energy sources-electrical, thermal, hydraulic, or stored pressure-and locks them off with a tag so equipment cannot be re-energized or started while someone is servicing it.
- Stagnation
- Related: Flash steam, Drainback system, Glycol
The condition in which a solar thermal system stops transferring heat because the pump is off or storage is full, letting the collector sit at very high temperature; repeated stagnation can degrade glycol and damage components.
- Flash steam
- Related: Stagnation, Pressure relief valve
Steam that forms suddenly when pressurized hot water is released to a lower pressure, for example when a relief valve opens or a fitting is loosened; it can cause severe burns and must be anticipated during service.
- Solar window
- Related: Shading analysis, Azimuth, Collector tilt angle
The portion of the sky, expressed in hours per day or a sun-path diagram, where the sun must be unobstructed for a collector to produce useful energy; obstructions inside it reduce output.
- Azimuth
- Related: Collector tilt angle, Solar window
The compass direction a collector surface faces, measured in degrees clockwise from true north; in the northern hemisphere solar collectors typically face south, with southeast or southwest also acceptable.
- Collector tilt angle
- Related: Azimuth, Solar window
The angle between a collector's surface and horizontal, chosen to balance summer and winter sun angles and to shed snow or rain; it strongly influences annual energy collection.
- Shading analysis
- Related: Solar window, Design package
A site evaluation that maps nearby trees, buildings, and roof features through the seasons to determine how much sun reaches a proposed collector location and when.
- Solar fraction
- Related: Design package
The share of a building's total water-heating load supplied by the solar system rather than by the backup heater, usually estimated during design and verified over a year of operation.
- Design package
- Related: Shading analysis, Solar fraction, Roof structural load
The set of drawings, calculations, equipment schedules, and specifications that defines a solar water or pool heating installation and is reviewed before work begins.
- Roof structural load
- Related: Wind uplift, Standoff, Design package
The additional dead and live loads a collector array and its mounting hardware impose on a roof structure, which must be checked against the building's design capacity.
- Standoff
- Related: Flashing, Penetration
A short structural post or bracket fastened to the roof framing that raises mounting rails above the roofing surface, creating space for flashing and airflow.
- Flashing
- Related: Standoff, Penetration
Metal or membrane material installed around a roof penetration to shed water and prevent leaks; it must be integrated with the roofing layers and sealed to the mount.
- Wind uplift
- Related: Roof structural load
The upward force wind exerts on a collector array, especially at edges and corners, which the mounting design must resist through anchorage and load distribution.
- Penetration
- Related: Flashing, Standoff
A hole made through the roofing and sheathing to anchor mounting hardware; each one is a potential leak path and must be sealed with proper flashing.
- Closed-loop system
- Related: Glycol, Expansion tank, Heat exchanger
A solar water heating system in which a heat-transfer fluid circulates through collectors and a heat exchanger in a sealed circuit, protecting it from freezing and contamination.
- Drainback system
- Related: Stagnation, Air vent
A solar thermal design in which the collector loop drains into a reservoir when the pump stops, leaving collectors empty to avoid freezing and overheating.
- Glycol
- Related: Closed-loop system, Stagnation, Expansion tank
A freeze-protection fluid, usually propylene glycol mixed with water, circulated in closed-loop collectors; its concentration and condition must be checked because it degrades with heat and age.
- Expansion tank
- Related: Closed-loop system, Pressure relief valve
A vessel with a captive air cushion or bladder that absorbs the volume increase of heated fluid in a closed loop, limiting pressure rise and protecting components.
- Pressure relief valve
- Related: Expansion tank, Flash steam, Stagnation
A safety device that opens at a set pressure to release fluid or steam from a closed loop, preventing overpressure and rupture of tanks, piping, or collectors.
- Tempering valve
- Related: Heat exchanger
A mixing valve that blends hot storage water with cold water to deliver a safe, limited temperature at fixtures, reducing scald risk from solar-heated water.
- Heat exchanger
- Related: Closed-loop system, Tempering valve
A device that transfers heat from the collector loop fluid to potable water or pool water without mixing the two fluids, often a coil, side-arm, or plate type.
- Pool loop
- Related: Circulator pump, Flow rate
The piping and components that circulate pool water through a solar collector array and back to the pool, usually including a filter, pump, check valve, and automatic controls.
- Air vent
- Related: Drainback system, Circulator pump, Flushing
A valve or fitting that releases trapped air from a hydronic loop so that flow is not blocked and pumps do not cavitate; air elimination is essential at high points.
- Differential temperature controller
- Related: Collector temperature sensor, Tank sensor, Delta-T
An electronic control that compares collector and tank temperatures and turns the pump on when the collector is hotter by a set difference, off when the gain disappears.
- Collector temperature sensor
- Related: Differential temperature controller, Tank sensor
A sensor, usually a thermistor, clamped to the collector absorber or outlet to report collector temperature to the controller for pump switching and freeze protection.
- Tank sensor
- Related: Differential temperature controller, High-limit setpoint
A temperature sensor mounted in the storage tank at a location that represents usable hot water, sending readings to the controller for pump and backup control.
- High-limit setpoint
- Related: Tank sensor, Differential temperature controller, Stagnation
A maximum temperature setting in the control system that stops the pump or heat input to protect against overheating, scalding, or glycol degradation.
- Circulator pump
- Related: Flow rate, Air vent, Differential temperature controller
A pump that moves heat-transfer fluid through collectors, piping, and heat exchangers; its flow rate and head must match the loop's design requirements.
- Low-voltage control wiring
- Related: Differential temperature controller, Collector temperature sensor
The class 2 wiring that connects sensors, switches, and controllers, carrying signal-level power rather than mains voltage and requiring separation from line-voltage conductors.
- Commissioning
- Related: Flushing, Pressure test, Flow rate
The systematic process of verifying that an installed system operates as designed, including flushing, pressure testing, flow balancing, control checks, and documenting performance.
- Flow rate
- Related: Delta-T, Circulator pump, Commissioning
The volume of fluid moving through the collector loop per unit time, usually set in liters or gallons per minute to match the array's design and achieve the intended temperature rise.
- Delta-T
- Related: Flow rate, Differential temperature controller
The temperature difference between the collector outlet and inlet, or between collector and tank, used to control pump operation and to check that the array is transferring heat properly.
- Flushing
- Related: Pressure test, Air vent, Commissioning
Purging a new or repaired loop with clean fluid to remove debris, solder flux, and air before filling, protecting pumps, valves, and heat exchangers from fouling or blockage.
- Pressure test
- Related: Flushing, Commissioning
A hydrostatic test in which the piping or loop is filled and pressurized above operating pressure and held to confirm joints and components do not leak.
- Customer handover
- Related: Commissioning, Tempering valve
The final step in which the installer explains system operation, maintenance tasks, and safety precautions, and provides manuals, warranties, and contact information to the owner.