Fall protection

Systems and practices that prevent a worker from falling from a roof or elevated platform, such as guardrails, personal fall-arrest harnesses, and anchor points, plus the training and inspection needed to use them correctly.

Related: Lockout/tagout
Lockout/tagout

A safety procedure that isolates energy sources-electrical, thermal, hydraulic, or stored pressure-and locks them off with a tag so equipment cannot be re-energized or started while someone is servicing it.

Related: Fall protection, Pressure test
Stagnation

The condition in which a solar thermal system stops transferring heat because the pump is off or storage is full, letting the collector sit at very high temperature; repeated stagnation can degrade glycol and damage components.

Related: Flash steam, Drainback system, Glycol
Flash steam

Steam that forms suddenly when pressurized hot water is released to a lower pressure, for example when a relief valve opens or a fitting is loosened; it can cause severe burns and must be anticipated during service.

Related: Stagnation, Pressure relief valve
Solar window

The portion of the sky, expressed in hours per day or a sun-path diagram, where the sun must be unobstructed for a collector to produce useful energy; obstructions inside it reduce output.

Related: Shading analysis, Azimuth, Collector tilt angle
Azimuth

The compass direction a collector surface faces, measured in degrees clockwise from true north; in the northern hemisphere solar collectors typically face south, with southeast or southwest also acceptable.

Related: Collector tilt angle, Solar window
Collector tilt angle

The angle between a collector's surface and horizontal, chosen to balance summer and winter sun angles and to shed snow or rain; it strongly influences annual energy collection.

Related: Azimuth, Solar window
Shading analysis

A site evaluation that maps nearby trees, buildings, and roof features through the seasons to determine how much sun reaches a proposed collector location and when.

Related: Solar window, Design package
Solar fraction

The share of a building's total water-heating load supplied by the solar system rather than by the backup heater, usually estimated during design and verified over a year of operation.

Related: Design package
Design package

The set of drawings, calculations, equipment schedules, and specifications that defines a solar water or pool heating installation and is reviewed before work begins.

Related: Shading analysis, Solar fraction, Roof structural load
Roof structural load

The additional dead and live loads a collector array and its mounting hardware impose on a roof structure, which must be checked against the building's design capacity.

Related: Wind uplift, Standoff, Design package
Standoff

A short structural post or bracket fastened to the roof framing that raises mounting rails above the roofing surface, creating space for flashing and airflow.

Related: Flashing, Penetration
Flashing

Metal or membrane material installed around a roof penetration to shed water and prevent leaks; it must be integrated with the roofing layers and sealed to the mount.

Related: Standoff, Penetration
Wind uplift

The upward force wind exerts on a collector array, especially at edges and corners, which the mounting design must resist through anchorage and load distribution.

Related: Roof structural load
Penetration

A hole made through the roofing and sheathing to anchor mounting hardware; each one is a potential leak path and must be sealed with proper flashing.

Related: Flashing, Standoff
Closed-loop system

A solar water heating system in which a heat-transfer fluid circulates through collectors and a heat exchanger in a sealed circuit, protecting it from freezing and contamination.

Related: Glycol, Expansion tank, Heat exchanger
Drainback system

A solar thermal design in which the collector loop drains into a reservoir when the pump stops, leaving collectors empty to avoid freezing and overheating.

Related: Stagnation, Air vent
Glycol

A freeze-protection fluid, usually propylene glycol mixed with water, circulated in closed-loop collectors; its concentration and condition must be checked because it degrades with heat and age.

Related: Closed-loop system, Stagnation, Expansion tank
Expansion tank

A vessel with a captive air cushion or bladder that absorbs the volume increase of heated fluid in a closed loop, limiting pressure rise and protecting components.

Related: Closed-loop system, Pressure relief valve
Pressure relief valve

A safety device that opens at a set pressure to release fluid or steam from a closed loop, preventing overpressure and rupture of tanks, piping, or collectors.

Related: Expansion tank, Flash steam, Stagnation
Tempering valve

A mixing valve that blends hot storage water with cold water to deliver a safe, limited temperature at fixtures, reducing scald risk from solar-heated water.

Related: Heat exchanger
Heat exchanger

A device that transfers heat from the collector loop fluid to potable water or pool water without mixing the two fluids, often a coil, side-arm, or plate type.

Related: Closed-loop system, Tempering valve
Pool loop

The piping and components that circulate pool water through a solar collector array and back to the pool, usually including a filter, pump, check valve, and automatic controls.

Related: Circulator pump, Flow rate
Air vent

A valve or fitting that releases trapped air from a hydronic loop so that flow is not blocked and pumps do not cavitate; air elimination is essential at high points.

Related: Drainback system, Circulator pump, Flushing
Differential temperature controller

An electronic control that compares collector and tank temperatures and turns the pump on when the collector is hotter by a set difference, off when the gain disappears.

Related: Collector temperature sensor, Tank sensor, Delta-T
Collector temperature sensor

A sensor, usually a thermistor, clamped to the collector absorber or outlet to report collector temperature to the controller for pump switching and freeze protection.

Related: Differential temperature controller, Tank sensor
Tank sensor

A temperature sensor mounted in the storage tank at a location that represents usable hot water, sending readings to the controller for pump and backup control.

Related: Differential temperature controller, High-limit setpoint
High-limit setpoint

A maximum temperature setting in the control system that stops the pump or heat input to protect against overheating, scalding, or glycol degradation.

Related: Tank sensor, Differential temperature controller, Stagnation
Circulator pump

A pump that moves heat-transfer fluid through collectors, piping, and heat exchangers; its flow rate and head must match the loop's design requirements.

Related: Flow rate, Air vent, Differential temperature controller
Low-voltage control wiring

The class 2 wiring that connects sensors, switches, and controllers, carrying signal-level power rather than mains voltage and requiring separation from line-voltage conductors.

Related: Differential temperature controller, Collector temperature sensor
Commissioning

The systematic process of verifying that an installed system operates as designed, including flushing, pressure testing, flow balancing, control checks, and documenting performance.

Related: Flushing, Pressure test, Flow rate
Flow rate

The volume of fluid moving through the collector loop per unit time, usually set in liters or gallons per minute to match the array's design and achieve the intended temperature rise.

Related: Delta-T, Circulator pump, Commissioning
Delta-T

The temperature difference between the collector outlet and inlet, or between collector and tank, used to control pump operation and to check that the array is transferring heat properly.

Related: Flow rate, Differential temperature controller
Flushing

Purging a new or repaired loop with clean fluid to remove debris, solder flux, and air before filling, protecting pumps, valves, and heat exchangers from fouling or blockage.

Related: Pressure test, Air vent, Commissioning
Pressure test

A hydrostatic test in which the piping or loop is filled and pressurized above operating pressure and held to confirm joints and components do not leak.

Related: Flushing, Commissioning
Customer handover

The final step in which the installer explains system operation, maintenance tasks, and safety precautions, and provides manuals, warranties, and contact information to the owner.

Related: Commissioning, Tempering valve