NATE AC Installation key terms
NATE AC Installation · Get comfortable with the vocabulary.
- Dry-bulb temperature
- Related: Wet-bulb temperature, Temperature split, Relative humidity
The temperature of air measured with an ordinary thermometer, unaffected by moisture content. Installers record it at the return and supply to check the temperature split and, with wet-bulb, to estimate humidity.
- Wet-bulb temperature
- Related: Dry-bulb temperature, Relative humidity, Target superheat
The lowest temperature air can reach as water evaporates into it, read with a thermometer whose bulb is wrapped in a wet wick. It indicates how much moisture the air can still absorb.
- Relative humidity
- Related: Wet-bulb temperature, Dew point
The percentage of moisture air holds compared with the most it could hold at that same temperature. High values slow evaporative cooling, add latent load, and make the coil work longer to satisfy the thermostat.
- Dew point
- Related: Relative humidity, Condensate trap
The temperature at which air becomes saturated and moisture starts condensing on surfaces. Coil and duct surfaces must stay below it so water forms and drains rather than fogging the space.
- Design conditions
- Related: Temperature split, Target superheat
The outdoor and indoor temperature and humidity values used to size equipment, select airflow, and set expectations. They come from local weather data and agreed comfort targets, not one afternoon's reading.
- Temperature split
- Related: Dry-bulb temperature, External static pressure, Superheat
The difference between return-air and supply-air temperatures across the equipment, commonly 16 to 22 degrees Fahrenheit in residential cooling. A split outside that range points to airflow, charge, or duct problems.
- Saturation temperature
- Related: Superheat, Subcooling
The temperature at which a refrigerant boils or condenses at a given pressure. Gauges convert pressure into this value so line temperatures can be compared with it to figure superheat and subcooling.
- Evaporator coil
- Related: Condenser coil, Condensate trap, Thermostatic expansion valve
The indoor heat exchanger where low-pressure liquid refrigerant boils and absorbs heat from household air. Its surface stays below the dew point, so the water it condenses must be trapped and drained.
- Condenser coil
- Related: Evaporator coil, Subcooling
The outdoor heat exchanger that rejects heat gathered indoors and turns refrigerant vapor back into liquid. It needs clean fins and unobstructed airflow to keep discharge pressure within the manufacturer's range.
- Compressor
- Related: Locked rotor amps, Running load amps, Contactor
The pump that raises refrigerant pressure and moves it around the circuit. It draws low-pressure vapor from the evaporator and discharges hot, high-pressure vapor toward the condenser.
- Thermostatic expansion valve
- Related: Superheat, Evaporator coil, Subcooling
A modulating metering device that regulates refrigerant flow into the evaporator to hold superheat near a set value. It reacts to evaporator outlet temperature and pressure, unlike a fixed-bore piston.
- Filter drier
- Related: Micron gauge, Thermostatic expansion valve
A liquid-line device with a screen and desiccant that catches debris and absorbs moisture left after assembly or service. Installers braze it in with the arrow pointing toward the metering device.
- Reversing valve
- Related: Evaporator coil, Condenser coil
A four-way valve in heat pumps that swaps which coil acts as evaporator and which as condenser, allowing one system to heat or cool. Its solenoid coil is energized in only one mode.
- Condensate trap
- Related: Dew point, External static pressure, Evaporator coil
A water seal formed in the drain line that blocks air from being pulled through the drain and lets condensate leave the pan. Its depth must suit the fan's static pressure or water will be held or blown out.
- Line set
- Related: Evaporator coil, Filter drier
The copper tubing pair, usually with the control wire, that joins the outdoor unit to the indoor coil. Properly insulated suction line prevents heat gain and sweating in humid spaces.
- MERV rating
- Related: External static pressure, Return air, Filter bypass
A standardized score for how well a filter captures particles of a given size range. Higher ratings trap finer particles but resist airflow more, so the choice must match blower capacity.
- External static pressure
- Related: MERV rating, Return air, Duct leakage
The resistance to airflow measured in the supply and return ducts outside the air handler, expressed in inches of water column. High readings indicate restrictive filters, tight ducts, or a fouled coil.
- Return air
- Related: MERV rating, Temperature split, Duct leakage
Air drawn back from the conditioned space to be filtered, cooled, and supplied again. Undersized or blocked return paths starve the blower and reduce delivered capacity.
- Duct leakage
- Related: Return air, External static pressure
Air escaping from or entering ducts through seams, joints, and holes instead of reaching rooms. Return-side leaks pull hot attic air in, while supply leaks waste cooled air.
- Outdoor air ventilation
- Related: Relative humidity, Duct leakage
Fresh air brought in on purpose to dilute indoor pollutants and limit stale odors. Installers must weigh it against the extra sensible and latent load it adds to the cooling equipment.
- Filter bypass
- Related: MERV rating, Evaporator coil
Air that slips around a filter's edges instead of passing through the media, carrying dirt directly onto the coil. Correct filter sizing and a sealed frame eliminate it.
- Locked rotor amps
- Related: Running load amps, Compressor, Dual run capacitor
The current a motor draws at startup when the rotor cannot turn, printed on the nameplate. Measured inrush current is compared with this figure to judge winding and capacitor condition.
- Running load amps
- Related: Locked rotor amps, Compressor
The current a motor draws while operating under normal load, listed on the nameplate or in the manufacturer's tables. Readings far above it suggest high head pressure, low voltage, or a failing motor.
- Dual run capacitor
- Related: Locked rotor amps, Contactor
One capacitor serving both the compressor and the outdoor fan motor, with three terminals and two capacitance values. A bulged or out-of-tolerance unit can stop the compressor from starting.
- Contactor
- Related: Control transformer, Dual run capacitor, Compressor
A relay whose 24-volt coil closes high-voltage contacts that start the compressor and outdoor fan. Pitted or burned contacts cause voltage drop and intermittent operation.
- Control transformer
- Related: Contactor, Equipment grounding conductor
A small transformer that steps line voltage down to 24 volts for the thermostat and control circuit. A shorted low-voltage wire or miswired thermostat can burn out its secondary winding.
- Equipment grounding conductor
- Related: Disconnect switch, Control transformer
The green or bare wire bonding metal enclosures and the compressor shell back to the panel. It carries fault current so the breaker trips instead of leaving the cabinet energized.
- Disconnect switch
- Related: Equipment grounding conductor, Locked rotor amps
A service switch installed near the outdoor unit that removes all power for safe servicing. It must be within sight of the equipment and rated for the circuit's voltage and current.
- Superheat
- Related: Subcooling, Saturation temperature, Target superheat
How many degrees a vapor is above its saturation temperature at the measured pressure. Taken at the evaporator outlet, it shows whether the metering device is feeding the coil correctly.
- Subcooling
- Related: Superheat, Saturation temperature, Thermostatic expansion valve
How many degrees a liquid is below its saturation temperature, measured at the condenser outlet. It reveals how much liquid is stacked in the condenser and is the main charging check on expansion-valve systems.
- Target superheat
- Related: Superheat, Wet-bulb temperature, Weigh-in charging
The superheat a manufacturer specifies for the current indoor wet-bulb and outdoor dry-bulb readings. On fixed-orifice systems, charge is adjusted until measured superheat matches this number.
- Weigh-in charging
- Related: Subcooling, Target superheat
Adding or removing refrigerant by weight per the nameplate charge, corrected for line-set length and component volume. It is the dependable method when conditions fall outside the charging chart.
- Micron gauge
- Related: Nitrogen pressure test, Filter drier, Gauge manifold
An electronic instrument that reads deep vacuum in microns during evacuation. A reading of 500 microns or lower that holds steady after valving off confirms the system is dry and tight.
- Nitrogen pressure test
- Related: Micron gauge, Filter drier
Pressurizing an isolated circuit with dry nitrogen and watching the gauge to locate leaks before charging. Nitrogen adds no moisture and is never released as a refrigerant substitute.
- Airflow measurement (CFM)
- Related: External static pressure, Temperature split
Finding the volume of air the blower moves in cubic feet per minute, usually from fan tables using measured static pressure, or directly with a flow hood at the registers.
- Gauge manifold
- Related: Superheat, Subcooling, Micron gauge
A set of gauges and hoses used to read suction and discharge pressures and to move refrigerant in or out. Hoses must be purged so air and moisture never enter the circuit.