Lockout/Tagout (LOTO)

A required procedure for shutting off and isolating energy sources, such as electrical disconnects or gas valves, and applying locks and tags so equipment cannot be re-energized while someone works on it.

Related: Personal Protective Equipment (PPE), Confined Space Entry
Personal Protective Equipment (PPE)

Wearable safety gear such as safety glasses, gloves, hard hats, hearing protection, and respirators that protects the installer from jobsite hazards including sharp metal edges, dust, and noise.

Related: Lockout/Tagout (LOTO)
Confined Space Entry

A permit-controlled process for entering spaces with limited access or poor ventilation, such as plenums, crawlspaces, or mechanical rooms, requiring atmospheric testing and an attendant before entry.

Related: Lockout/Tagout (LOTO)
Fall Protection

Systems and practices, including guardrails, personal fall arrest harnesses, and ladder safety rules, used to prevent injury when working at heights such as rooftops or elevated platforms.

Related: Ladder Safety
Ladder Safety

Correct selection, setup angle, inspection, and three-point contact practices for ladders, plus rules limiting reach and requiring secure footing before climbing to install or service ductwork.

Related: Fall Protection
Manual D

An ACCA residential duct design method that sizes ducts using room-by-room airflow, available static pressure, and a calculated equivalent-length friction rate so each terminal receives its design airflow.

Related: Equivalent Length, Available Static Pressure, Friction Rate
Manual J

An ACCA method for calculating residential heating and cooling loads room by room from construction details, orientation, and climate data; its results drive equipment and airflow selection.

Related: Manual D, Room Airflow
Equivalent Length

The total effective resistance of a duct run expressed in feet of straight duct, adding fitting losses from elbows, tees, and transitions to actual measured length.

Related: Friction Rate, Available Static Pressure, Fitting Loss
Friction Rate

The pressure drop per 100 feet of duct run that a design uses to size ductwork, derived from available static pressure divided by total equivalent length.

Related: Equivalent Length, Available Static Pressure
Available Static Pressure

The portion of a blower's total external static pressure left for the supply and return duct system after subtracting pressure drops of coils, filters, grilles, and other components.

Related: External Static Pressure, Friction Rate
External Static Pressure (ESP)

The resistance to airflow measured across the air handler, including the duct system and accessories, usually expressed in inches of water column and compared with blower rating tables.

Related: Available Static Pressure, Velocity Pressure
Velocity Pressure

The pressure component associated with air speed in a duct, used with a pitot tube or flow grid to calculate velocity and airflow; it rises with the square of velocity.

Related: External Static Pressure (ESP), Traverse
Room Airflow

The design cubic feet per minute a room requires, determined from its heating and cooling load and supply-to-room temperature difference, and used to size the branch run and terminal.

Related: Manual J, Manual D
Fitting Loss

Pressure lost as air passes through an elbow, tee, takeoff, transition, or boot; it depends on fitting geometry and velocity and is added to straight-duct loss in design calculations.

Related: Equivalent Length
Aspect Ratio

The width-to-height ratio of a rectangular duct cross section; higher ratios increase friction and are generally limited to about 4:1 to keep pressure loss reasonable.

Related: Friction Rate
Galvanized Steel Duct

Ductwork formed from zinc-coated steel sheet, commonly used in commercial and residential systems; gauge selection depends on duct size and required static pressure.

Related: Duct Gauge, Spiral Duct
Duct Gauge

The thickness designation of sheet metal duct, where lower numbers mean thicker metal; minimum gauges are set by standards based on duct dimensions and system pressure class.

Related: Galvanized Steel Duct, Pressure Class
Spiral Duct

Round duct made by winding a continuous metal strip into a spiral seam, offering low friction loss and high stiffness for exposed or long runs.

Related: Galvanized Steel Duct, Duct Gauge
Flexible Duct

A factory-made duct with a wire helix and flexible jacket, used for short final connections; it must be installed taut, with limited sag and bends, to avoid excess pressure loss.

Related: Takeoff, Friction Rate
Duct Board

Rigid insulation board, often faced with foil or coated material, fabricated into duct sections; joints and seams must be sealed to control leakage and vapor migration.

Related: Vapor Barrier, Mastic
Takeoff

A fitting that branches from a main trunk to feed a branch run, available in round, rectangular, and boot styles; its shape strongly affects pressure loss and airflow balance.

Related: Flexible Duct, Fitting Loss
Duct Hanger Spacing

The maximum interval between supports for ductwork, set by code and manufacturer instructions, so the duct does not sag, rack, or separate at joints.

Related: Duct Gauge, Seismic Restraint
Seismic Restraint

Bracing, cables, and anchors that keep ductwork and equipment from shifting during earthquakes, required in many jurisdictions and specified by seismic design categories.

Related: Duct Hanger Spacing
Pittsburgh Seam

A common rectangular duct seam with interlocking folded edges that is mechanically strong and, when sealed, resists air leakage along the longitudinal joint.

Related: Drive Cleat, Mastic
Drive Cleat

A channel-shaped metal strip slipped over the folded edges of adjoining rectangular duct sections to lock the transverse joint together before it is sealed.

Related: Pittsburgh Seam, Mastic
Mastic

A thick brushable or trowelable sealant applied to duct seams and joints to limit air leakage; it must be compatible with the duct material and rated for the pressure class.

Related: Pressure Class, Vapor Barrier
Pressure Class

A rating that groups duct systems by the static pressure they must contain, such as half-inch or one-inch water gauge, and sets required gauge, reinforcement, and seal level.

Related: Duct Gauge, Mastic
Supply Plenum

The box or duct section directly attached to the blower outlet that distributes conditioned air into the supply trunk and branch runs.

Related: Return Plenum, Takeoff
Return Plenum

The duct section or chamber connected to the blower inlet that collects return air from the conditioned space and delivers it back to the air handler.

Related: Supply Plenum
Volume Damper

An adjustable blade inside a duct, branch, or terminal that throttles airflow so the delivered cubic feet per minute can be balanced to design values.

Related: Balancing, Register
Balancing

The process of measuring and adjusting dampers, registers, and fan settings so each zone and room receives its design airflow within acceptable tolerance.

Related: Volume Damper, Traverse
Register

A grille with an integral damper or deflector that covers a supply or return opening and directs or adjusts the air entering the room.

Related: Diffuser, Throw
Diffuser

An air outlet with vanes or cones that spreads supply air in a designed pattern, promoting mixing and avoiding drafts in the occupied zone.

Related: Register, Throw
Throw

The horizontal or vertical distance air travels from an outlet before its velocity drops to a specified terminal value, used to judge draft risk and mixing.

Related: Diffuser, Register
Vapor Barrier

A low-permeance layer that limits moisture diffusion through duct insulation or building assemblies, keeping the cold duct surface above the dew point.

Related: Duct Board, Mastic
Traverse

A measurement of airflow made by averaging velocity readings across a duct cross section with a pitot tube or flow grid at a location with stable, uniform flow.

Related: Velocity Pressure, Balancing
Duct Leakage Test

A pressurization test that measures air lost through duct seams and joints, often reported as leakage class or percent of design flow and compared with specification limits.

Related: Pressure Class, Mastic
Test and Balance (TAB) Report

The documented record of measured airflows, pressures, fan speeds, and final damper positions produced after commissioning, used to verify the system meets design intent.

Related: Balancing, Traverse
Commissioning

The organized process of verifying that installed duct and air distribution systems operate as designed, including functional testing, balancing, and documentation closeout.

Related: Test and Balance (TAB) Report
International Mechanical Code (IMC)

A model code adopted in many jurisdictions that sets requirements for duct materials, installation, clearances, sealing, and ventilation, referenced by local permits and inspections.

Related: SMACNA Standards, Pressure Class
SMACNA Standards

Industry publications from the Sheet Metal and Air Conditioning Contractors' National Association that specify duct construction, pressure classes, reinforcement, and sealing requirements.

Related: Pressure Class, Duct Gauge
Submittal

Product data, drawings, and calculations sent to the designer for approval before installation, confirming duct materials, gauges, sealants, and equipment meet the specification.

Related: As-Built Drawing
As-Built Drawing

A drawing updated to show the ductwork and equipment as actually installed, including routing changes and field modifications, and used for closeout and future service.

Related: Submittal