- Permit requirement
- Most plumbing installations, alterations, and replacements require a permit issued by the local authority having jurisdiction before work begins.
- Rough-in inspection
- An inspection performed after piping is installed but before it is covered by walls, floors, or ceilings, allowing the inspector to verify code compliance.
- DWV air test
- A drainage test using compressed air at about 5 psi held for 15 minutes with no pressure drop, used where a water test is impractical.
- Developed length
- The total measured length of a pipe run along its centerline, including the equivalent lengths added for fittings, valves, and bends.
- Fixture unit
- A unit expressing the probable load a fixture places on the drainage or water supply system, used to size pipes from code tables.
- Vent termination height
- A vent must extend at least 6 inches above the roof surface and be kept a minimum distance from windows, doors, and air intakes.
- Water closet clearance
- A water closet needs at least 15 inches from its centerline to a side wall and 21 inches of clear space in front of the bowl.
- Trap seal depth
- The vertical depth of water in a trap that blocks sewer gas, normally between 2 and 4 inches and maintained by the trap design.
- Air gap
- The unobstructed vertical distance between a water supply outlet and the flood-level rim of a fixture, giving the highest backflow protection.
- TPR discharge pipe
- A full-size, gravity-drained pipe from a water heater relief valve that terminates safely and is never capped, reduced, or trapped.
- Flushometer pressure
- A flushometer valve typically requires a minimum of 15 psi static pressure at the fixture to operate and flush properly.
- Trap primer
- A device or connection that adds water to a floor drain trap to replace evaporation and keep the trap seal intact.
- Maximum system pressure
- Distribution systems are limited to about 80 psi; above that, a pressure-reducing valve is installed to protect fixtures and piping.
- Thermal expansion tank
- A tank installed on a closed water system to absorb the increased volume created when water is heated in the water heater.
- Copper tube types
- Type L copper is commonly used for underground and general service, while Type M is thinner and used for interior above-ground lines.
- RPZ assembly
- A reduced-pressure-zone backflow preventer used for high-hazard cross-connections; it must be tested and maintained on a regular schedule.
- Hot water side
- In standard practice hot water is supplied on the left side of a fixture and cold on the right, viewed facing the fixture.
- Main shutoff valve
- A valve at the service entry that stops all water to the building, used for emergencies and repairs; each fixture branch also has a valve.
- Drain slope rule
- Drains 2 inches and smaller slope at 1/4 inch per foot; larger drains commonly slope at 1/8 inch per foot to maintain scouring velocity.
- Building drain
- The lowest piping inside the building that receives soil and waste and conveys it to the building sewer outside the foundation.
- Trap arm length
- The distance from a fixture trap to its vent, limited by pipe size, such as 8 feet for a 2-inch trap arm.
- Wet vent
- A vent that also carries waste from fixtures on the same floor, sized according to the vent tables and not permitted for all fixtures.
- Cleanout placement
- Cleanouts are required at the base of stacks, at the building drain, at sharp direction changes, and at intervals along long horizontal runs.
- Backwater valve
- A valve installed on a drain to prevent sewage from backing up into a building when the public sewer surcharges or floods.
- Stack vent
- The extension of a soil or waste stack above the highest fixture connection, providing air to the drainage system and terminating outside.
- Confined space testing
- Before entering a sewer or vault, test for oxygen, combustible gas, and hydrogen sulfide and keep a standby person outside.
- Basin wrench
- A long-handled wrench with a pivoting jaw used to reach and turn faucet mounting nuts in the tight space behind a sink.
- Gas leak detection
- Gas leaks are found with a soap-and-water solution or an electronic detector; an open flame must never be used for testing.
- Hot work fire watch
- When soldering or brazing, remove combustibles, use a heat shield, and keep a fire extinguisher ready during and after the work.
- Pipe wrench use
- A pipe wrench grips round pipe with serrated jaws; turning force is applied in the direction that tightens the jaw onto the pipe.
- Hose bibb vacuum breaker
- A device attached to an outdoor hose connection to prevent backflow of contaminated water into the potable supply when a hose is submerged.
- Deburring tool
- A tool used to ream the cut end of copper or plastic pipe, removing burrs that would restrict flow and create turbulence.
- Manometer
- An instrument that measures low gas or air pressure, used to verify test pressure and to check gas appliance operating pressure.