ND Journeyman Plumber key terms
ND Journeyman Plumber · Get comfortable with the vocabulary.
- Uniform Plumbing Code (UPC)
- Related: Authority Having Jurisdiction (AHJ), Code Adoption
A model plumbing code adopted by many jurisdictions that sets minimum requirements for the design, installation, and maintenance of plumbing systems, fixtures, and appliances. Local amendments may modify its provisions.
- Authority Having Jurisdiction (AHJ)
- Related: Uniform Plumbing Code (UPC), Permit and Inspection
The individual or agency responsible for enforcing a code, approving materials and methods, and issuing permits and inspections. The AHJ interprets code provisions and may accept alternatives judged equivalent.
- Code Adoption
- Related: Uniform Plumbing Code (UPC), Authority Having Jurisdiction (AHJ)
The formal process by which a state or local government legally adopts a model plumbing code, often with local amendments. Only the adopted version, as amended, is enforceable in that jurisdiction.
- Permit and Inspection
- Related: Rough-In, Authority Having Jurisdiction (AHJ)
The approval required before installing or altering plumbing work, followed by required inspections at stages such as rough-in and final. Inspections verify that concealed and completed work complies with the adopted code.
- Rough-In
- Related: Permit and Inspection, DWV System
The stage of construction when piping, fittings, and fixture supports are installed before walls, floors, or fixtures are finished. Rough-in must be inspected and approved before being concealed.
- DWV System
- Related: Trap Seal, Vent Stack, Rough-In
The drainage, waste, and vent piping network that carries sewage and gray water away while admitting air to protect trap seals. Drain and vent piping are sized and installed as one coordinated system.
- Fixture Unit
- Related: Drainage Fixture Unit (DFU), Water Supply Fixture Unit (WSFU)
A dimensionless measure of the load a fixture places on the drainage or water supply system, based on its probable flow rate and use. Fixture units are totaled to size drain pipes and water service lines.
- Drainage Fixture Unit (DFU)
- Related: Fixture Unit, Building Drain
The drainage load value assigned to a fixture, reflecting the volume and rate of waste it discharges. Drainage fixture units from all connected fixtures are summed to determine required drain pipe size and slope.
- Water Supply Fixture Unit (WSFU)
- Related: Fixture Unit, Water Service Line
A demand value assigned to a fixture based on its hot and cold water flow requirements. Total water supply fixture units, adjusted for the type of building, determine the required size of the water service and distribution piping.
- Trap Seal
- Related: P-Trap, Vent Stack, Air Gap
The depth of water held in a fixture trap, typically two to four inches, that blocks sewer gas from entering a building. The seal is maintained by venting and is lost through evaporation, siphonage, or back pressure.
- P-Trap
- Related: Trap Seal, Fixture Drain, Air Gap
A U-shaped fitting beneath a fixture that holds a water seal and connects the fixture to the drainage system. It must be self-cleaning and accessible for cleaning unless removable without damage.
- Vent Stack
- Related: DWV System, Trap Seal, Air Admittance Valve (AAV)
A vertical vent pipe that extends from the drainage system to open air and provides relief for trap seals. It may serve multiple fixtures and must terminate at the required height above the roof.
- Air Admittance Valve (AAV)
- Related: Vent Stack, Trap Seal, DWV System
A one-way mechanical vent that admits air into drain piping to protect trap seals but does not allow sewer gas to escape. AAVs are permitted only where the code allows and must be installed accessibly.
- Building Drain
- Related: Building Sewer, Drainage Fixture Unit (DFU), Slope
The lowest horizontal piping of a drainage system that receives waste from soil and waste stacks and conveys it to the building sewer. It is typically sized by total drainage fixture units and installed at a uniform slope.
- Building Sewer
- Related: Building Drain, Backwater Valve
The pipe carrying sewage from the building drain to the public sewer or private disposal system. It lies outside the building foundation and is usually the owner's responsibility to maintain.
- Slope
- Related: Building Drain, Drainage Fixture Unit (DFU)
The downward pitch of horizontal drain pipe, expressed as fall per unit of length, that allows gravity flow and solids transport. Insufficient slope causes clogs; excessive slope can separate liquids from solids.
- Backwater Valve
- Related: Building Sewer, Backflow Preventer
A device installed on a drain line to prevent sewage from backing up into a building when the public sewer surcharges. It is required where fixtures are below the level of the next upstream manhole.
- Backflow Preventer
- Related: Air Gap, Cross-Connection, Backwater Valve
An assembly that prevents contaminated water from reversing flow into the potable water supply. Selection depends on the degree of hazard, and the device must be tested and maintained by qualified personnel.
- Cross-Connection
- Related: Backflow Preventer, Air Gap
Any actual or potential link between the potable water supply and a source of contamination or pollution. Cross-connections must be eliminated or protected by an air gap or approved backflow preventer.
- Air Gap
- Related: Cross-Connection, Backflow Preventer, Trap Seal
An unobstructed vertical separation between a water supply outlet and the flood level rim of a fixture or receptacle. It is the most reliable backflow protection and requires no moving parts.
- Water Service Line
- Related: Water Supply Fixture Unit (WSFU), Water Hammer Arrestor, Backflow Preventer
The pipe carrying potable water from the water main or private source to the building. It is sized using total water supply fixture units and must be installed below the local frost depth.
- Water Hammer Arrestor
- Related: Water Service Line, Pressure-Reducing Valve
A device containing a trapped air cushion or piston that absorbs pressure surges when valves close quickly. It is installed near quick-closing valves to reduce noise and protect piping and fittings.
- Pressure-Reducing Valve
- Related: Water Hammer Arrestor, Thermal Expansion
A device that lowers incoming water pressure to a safe level for the building's piping and fixtures. It is required when supply pressure exceeds the code limit and protects against leaks and fixture damage.
- Thermal Expansion
- Related: Pressure-Reducing Valve, Water Heater Temperature and Pressure Relief Valve
The increase in water volume as it is heated, which raises pressure in a closed system such as one with a backflow preventer. A thermal expansion tank absorbs this pressure and prevents relief valve discharge.
- Water Heater Temperature and Pressure Relief Valve
- Related: Thermal Expansion, Air Gap
A safety valve that discharges water if tank temperature or pressure exceeds safe limits. It must be piped to a safe discharge point, and the discharge pipe must not be capped or reduced in size.
- Water Closet
- Related: Closet Flange, Trap Seal, Fixture Unit
A toilet fixture that receives human waste and discharges it through a trap to the drainage system. Installation requires a water supply, a closet flange, and code-compliant clearances and venting.
- Closet Flange
- Related: Water Closet, P-Trap
A fitting that secures a water closet to the floor and connects its outlet to the drain pipe. It must be set level, fastened securely, and sealed to prevent leakage.
- Flood Level Rim
- Related: Air Gap, Backflow Preventer
The edge of a fixture or receptacle over which water would overflow onto the floor. It sets the reference height for air gaps and backflow protection and helps determine fixture overflow requirements.
- Fixture Drain
- Related: P-Trap, Trap Seal, Drainage Fixture Unit (DFU)
The pipe that carries waste from a fixture trap to the drainage system. It must be sized according to fixture units and slope requirements and is usually vented to protect the trap seal.
- Cleanout
- Related: Building Drain, Slope
An accessible opening in drainage piping that allows a drain snake or rod to clear blockages. Cleanouts are required at specified intervals, at changes of direction, and at the base of stacks.
- Shower Pan Liner
- Related: Flood Level Rim, Rough-In
A waterproof membrane installed under a shower floor to contain water and direct it to the drain. It must be sloped, lapped over the curb, and tested before tile is installed.
- Personal Protective Equipment (PPE)
- Related: Confined Space, Lockout/Tagout
Safety gear such as gloves, eye protection, and respirators worn to reduce injury and exposure on the job. Proper use is required when handling chemicals, soldering, or working in confined spaces.
- Confined Space
- Related: Personal Protective Equipment (PPE), Lockout/Tagout
A space large enough to enter but with limited entry or exit and not designed for continuous occupancy, such as a pit or vault. Entry requires atmospheric testing, ventilation, and an attendant outside.
- Lockout/Tagout
- Related: Personal Protective Equipment (PPE), Confined Space
A procedure that isolates energy sources and locks them off before servicing equipment to prevent unexpected startup. Only the person who applied the lock may remove it, following the site's energy control program.
- Hydrostatic Test
- Related: Rough-In, Permit and Inspection
A pressure test in which a piping system or container is filled with water and checked for leaks at a specified pressure. It verifies the integrity of drainage and water piping before concealment or final approval.
- Pipe Wrench
- Related: Personal Protective Equipment (PPE)
A heavy adjustable wrench with serrated jaws used to grip and turn threaded pipe and fittings. Correct sizing and proper jaw direction prevent damage to pipe and reduce slipping injuries.
- Solder and Flux
- Related: Water Service Line, Hydrostatic Test
Materials used to join copper tubing by capillary action, where flux cleans the metal and solder fills the joint gap. Lead-free solder is required for potable water piping.
- Gray Water
- Related: Building Drain, Cross-Connection
Wastewater from sinks, showers, and laundry that contains low levels of contamination and may be reused for irrigation under code conditions. It excludes toilet waste and kitchen sink discharge.