NJ Registered Journeyman Electrician · Get comfortable with the vocabulary.

Ground-fault circuit interrupter (GFCI)

A protective device that compares current leaving and returning on a circuit and trips quickly when a small imbalance indicates current is leaking to ground, reducing shock hazard at receptacles, bathrooms, kitchens, and other required locations.

Related: Equipment grounding conductor, Arc-fault circuit interrupter (AFCI)
Arc-fault circuit interrupter (AFCI)

A device that detects the characteristic current and voltage signature of dangerous parallel or series arcing in branch-circuit wiring and de-energizes the circuit, protecting against fire ignition at damaged conductors or loose connections.

Related: Ground-fault circuit interrupter (GFCI), Branch circuit
Equipment grounding conductor (EGC)

The conductor that connects the non-current-carrying metal parts of equipment, raceways, and enclosures to the system grounding point, providing a low-impedance fault path so overcurrent devices open during a ground fault.

Related: Bonding jumper, Ground-fault circuit interrupter (GFCI)
Grounded conductor

The intentionally grounded current-carrying conductor of a system, commonly the neutral, which returns current to the source and is bonded to ground at the service; it is distinct from the equipment grounding conductor.

Related: Service disconnect, Equipment grounding conductor (EGC)
Bonding jumper

A conductor, screw, or strap that ensures electrical continuity between metal parts that must be electrically connected, such as service equipment enclosures, metal raceways, and water piping, so they remain at the same potential.

Related: Equipment grounding conductor (EGC), Grounding electrode system
Grounding electrode system

The set of grounding electrodes, such as ground rods, metal water pipe, concrete-encased electrode, or ground ring, that are bonded together and connect the electrical system to earth to limit voltage surges and stabilize system voltage.

Related: Bonding jumper, Service disconnect
Service disconnect

The main switch or breaker that disconnects all ungrounded service conductors from the premises wiring, establishing the service point where the grounded conductor is bonded and the grounding electrode conductor is connected.

Related: Grounded conductor, Grounding electrode system
Overcurrent protective device (OCPD)

A fuse or circuit breaker designed to open a circuit automatically when current exceeds its rating for a set time, protecting conductors and equipment from overheating and short circuits.

Related: Branch circuit, Ampacity
Ampacity

The maximum current, in amperes, that a conductor or device can carry continuously under stated conditions without exceeding its temperature rating, adjusted for ambient temperature and number of current-carrying conductors.

Related: Overcurrent protective device (OCPD), Conductor derating
Conductor derating

The required reduction of a conductor's ampacity when several current-carrying conductors share a raceway or cable, or when ambient temperature exceeds the value on which the conductor's rating is based.

Related: Ampacity, Raceway
Voltage drop

The loss of voltage along a circuit caused by conductor resistance and reactance, calculated from current, conductor length, and conductor properties; excessive drop can cause poor equipment performance and is limited by code recommendations.

Related: Ampacity, Branch circuit
Branch circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlets or equipment it supplies; branch circuits are classified by rating, such as 15, 20, 30, or 50 amperes.

Related: Overcurrent protective device (OCPD), Feeders and service conductors
Feeders and service conductors

Feeders are conductors between the service equipment and the final branch-circuit overcurrent devices; service conductors run from the utility supply to the service disconnect and carry the entire premises load.

Related: Branch circuit, Service disconnect
Raceway

An enclosed channel of metal or nonmetallic material, such as conduit, tubing, or wireway, designed to hold and protect conductors and to permit pulling and replacement of wiring.

Related: Conductor derating, Cable tray and support systems
Cable tray and support systems

Structures and hardware, including trays, hangers, and supports, that carry and secure cables or raceways; support spacing and load ratings depend on the wiring method and must follow code requirements.

Related: Raceway, Box fill
Box fill

The code calculation of the minimum volume required for a box based on the number and size of conductors, devices, clamps, and grounding conductors it contains, preventing overcrowding and insulation damage.

Related: Raceway, Cable tray and support systems
Working clearance

The required clear space in front of electrical equipment, defined by depth, width, and height in the code, allowing safe access for inspection, maintenance, and emergency disconnection without obstruction.

Related: Lockout/tagout, Service disconnect
Lockout/tagout

A safety procedure in which an energy-isolating device is locked and tagged to prevent accidental re-energization while workers service equipment, with each worker applying a personal lock and tag.

Related: Working clearance, Personal protective equipment (PPE)
Personal protective equipment (PPE)

Clothing and gear, such as insulated gloves, arc-rated clothing, face shields, and safety glasses, selected for the voltage and incident-energy exposure of the task to protect workers from shock and arc flash.

Related: Lockout/tagout, Arc flash boundary
Arc flash boundary

The distance from energized equipment within which a person could receive a second-degree burn from an arc flash; it is used to determine required PPE and safe work distances.

Related: Personal protective equipment (PPE), Working clearance
Permit-required confined space

A space large enough to enter, with limited entry or exit, not designed for continuous occupancy, and containing hazards such as toxic gas, engulfment, or hazardous atmosphere; entry requires a written permit and attendant.

Related: Lockout/tagout, Personal protective equipment (PPE)
New Jersey Electrical Contractors Licensing Act of 1962

The New Jersey statute that created the licensing framework for electrical contractors and established the Board of Examiners of Electrical Contractors, setting qualifications, scope of work, and enforcement authority for electrical contracting in the state.

Related: Board of Examiners of Electrical Contractors, Electrical contractor license
Board of Examiners of Electrical Contractors

The New Jersey regulatory board that administers licensing examinations, issues licenses, adopts rules, investigates complaints, and disciplines licensees under the state electrical contracting law.

Related: New Jersey Electrical Contractors Licensing Act of 1962, Licensed journeyman electrician
Electrical contractor license

A license authorizing a business entity to offer and perform electrical contracting work in New Jersey; the business must designate a licensed electrical contractor or qualified individual responsible for code-compliant work.

Related: Licensed journeyman electrician, Board of Examiners of Electrical Contractors
Licensed journeyman electrician

An individual licensed by the state to perform electrical work under the supervision of a licensed electrical contractor, meeting experience and examination requirements set by the board.

Related: Electrical contractor license, Board of Examiners of Electrical Contractors
Continuing education requirement

The mandated number of approved instructional hours a licensee must complete during each renewal cycle to maintain licensure, covering code updates, safety, and business practices as adopted by the board.

Related: License renewal, Board of Examiners of Electrical Contractors
License renewal

The periodic process by which a licensee submits fees and evidence of continuing education to keep a license active; failing to renew on time can result in expiration or reinstatement requirements.

Related: Continuing education requirement, Electrical contractor license
Permit and inspection process

The required local procedure in which a licensed contractor obtains a permit before starting electrical work and the work is inspected by an authority having jurisdiction before being energized or concealed.

Related: Authority having jurisdiction (AHJ), Certificate of occupancy
Authority having jurisdiction (AHJ)

The organization, office, or individual responsible for approving equipment, installations, and procedures, typically a municipal electrical inspector enforcing the adopted code edition and local amendments.

Related: Permit and inspection process, New Jersey Uniform Construction Code
New Jersey Uniform Construction Code

The state construction code that adopts and amends model codes, including the electrical subcode, and governs permitting, inspection, and enforcement through local construction offices throughout New Jersey.

Related: Authority having jurisdiction (AHJ), Permit and inspection process
Certificate of occupancy

A document issued by the construction official confirming that completed work complies with approved plans and code requirements and that the space may lawfully be occupied or used.

Related: Permit and inspection process, New Jersey Uniform Construction Code
Change order

A written modification to a signed contract that documents changes in scope, price, or schedule, protecting both contractor and client by recording agreed revisions before the work proceeds.

Related: Contract documents, Lien rights
Contract documents

The complete set of drawings, specifications, general and supplementary conditions, and addenda that define the work and form the legal basis of the construction agreement.

Related: Change order, Lien rights
Lien rights

The statutory ability of a contractor or supplier to record a claim against real property for unpaid labor or materials, subject to notice and filing deadlines that must be strictly followed.

Related: Contract documents, Change order
Load calculation

The systematic method of totaling connected loads, applying demand factors, and sizing service and feeder conductors and overcurrent devices to safely supply the calculated demand.

Related: Ampacity, Feeders and service conductors
Demand factor

A ratio applied to total connected load to account for the fact that not all loads operate simultaneously, allowing smaller service and feeder equipment than the sum of all nameplate ratings.

Related: Load calculation, Ampacity
Coordination (selective)

The selection and setting of overcurrent devices so that the device nearest a fault opens first, isolating the problem while minimizing unnecessary power loss to unaffected portions of the system.

Related: Overcurrent protective device (OCPD), Load calculation
Explosion-proof and classified locations

Areas where flammable gases, vapors, dusts, or fibers may be present, requiring specially listed equipment and wiring methods classified by class, division or zone, and group to prevent ignition.

Related: Raceway, Authority having jurisdiction (AHJ)
Temporary power

Temporary wiring and receptacles installed for construction or similar short-term use, subject to specific code requirements for GFCI protection, support, and removal after the project ends.

Related: Ground-fault circuit interrupter (GFCI), Working clearance