Building Code clause G13
Foul water clause requiring safe removal of foul water from buildings to an appropriate outfall without nuisance, hazard, or objectionable odour affecting people or property.
Plumbers, Gasfitters and Drainlayers Act 2006
Statute requiring drainlayers to be registered and licensed by the Plumbers, Gasfitters and Drainlayers Board before carrying out or supervising drainlaying work.
Trade waste bylaw
Territorial authority regulation controlling discharge of industrial liquid waste into the public sewer; a written trade waste consent is normally required before discharging.
AS/NZS 3500.2
Joint Australian and New Zealand standard for sanitary plumbing and drainage covering design, gradients, venting, materials, installation and testing of below-ground and above-ground systems.
Gradient as a percentage
Fall divided by length multiplied by one hundred; a 1:60 grade equals about 1.67 percent fall across the run.
Self-cleansing velocity
Minimum velocity of roughly 0.6 metres per second at peak dry weather flow that keeps solids moving and stops sediment depositing in the drain.
Trap seal depth
Minimum 50 millimetres of water held in a trap; correct venting protects the seal from siphonage and pressure changes caused by discharge.
Discharge units
Relative flow values assigned to each fixture type and used with standard tables to size drains, stacks and vents correctly.
Minimum pipe cover
Typically 300 millimetres of soil over a private drain in landscaped ground, increased under driveways and vehicle areas where loads are greater.
Trench width rule
Commonly pipe outside diameter plus 300 millimetres, with a 600 millimetre practical minimum, allowing room to haunch and compact beside the pipe.
Expansive clay
Soil that swells and shrinks as moisture changes, moving pipes and requiring specific bedding, pipe class and often greater cover.
Percolation test
Falling head test in a trial hole measuring how quickly water drains through the soil, used to size on-site effluent application areas.
SN stiffness class
Ring stiffness rating of uPVC sewer pipe, such as SN4, SN8 or SN16; higher classes resist greater soil and traffic loads.
Butt fusion joint
Polyethylene joining method where squared pipe ends are heated and pressed together, producing a joint as strong as the parent pipe.
Roll-on rubber ring joint
Concrete pipe joint where a lubricated rubber ring on the spigot rolls into the socket, giving a flexible, sealed connection.
Solvent cement joint
uPVC joint made by priming and cementing cleaned, chamfered surfaces, then pushing fully home with a quarter turn and holding until set.
Socket facing upstream
Laying rule where sockets point against the direction of flow so spigots enter downstream, helping joints resist root entry and debris.
Inspection point
Access fitting required at the foot of stacks, at sharp bends, on long runs and near boundaries so the drain can be rodded and inspected.
Thrust block
Concrete block cast against a bend or tee on a pressure main to absorb unbalanced hydraulic thrust and stop joints pulling apart.
Compacted side support
Backfill placed and compacted evenly in layers on both sides of a flexible pipe, which is what allows the pipe to carry load.
Water test
Drain plugged at the low end and filled with water to the required head, commonly at least 1.5 metres above the highest point, then checked for leakage.
Pre-cover inspection
Building consent authority check of drainage before backfilling, confirming alignment, gradient, bedding and jointing match the approved plans.
Mandrel deflection test
Test pulling a mandrel or deflectometer through a flexible pipe after backfill to confirm it has not been flattened beyond permitted limits.
Grease interceptor
Chamber that separates and retains fats, oils and grease from kitchen trade waste before the sewer, and must be regularly pumped out.
AS/NZS 1547
Standard for on-site domestic wastewater management covering treatment system selection, land application area sizing and required setback distances.
pH discharge limit
Trade waste consents typically restrict discharge to a pH range of roughly 6 to 10 to protect sewers, treatment plants and workers.
Invert level
Level of the inside bottom of a pipe; burial depth is calculated as surface level minus invert level using one datum.
Longitudinal section
Profile drawing of a drain showing chainages, invert levels and grades between structures, used to confirm the fall achieved on site.
Record of work
Certification issued by a licensed drainlayer confirming the work complies with the applicable standard and falls within their licence class.
1.5 metre rule
Excavations deeper than 1.5 metres must be shored, benched or battered and inspected by a competent person before entry.
Notifiable event
Death, serious injury or dangerous incident that must be reported to WorkSafe New Zealand as soon as practicable and then investigated.
Site-specific safety plan
Document identifying site hazards, controls, emergency arrangements and responsibilities, prepared before drainage work starts on the contract.