- Manual J load calculation
- Related: Manual D duct design, design temperature
A room-by-room method of estimating heating and cooling loads from envelope areas, insulation, windows, infiltration, and design temperatures. It sizes equipment correctly instead of relying on rules of thumb.
- Manual D duct design
- Related: Manual J load calculation, external static pressure
A procedure for sizing supply and return ducts using available static pressure, equivalent length, and friction rate so the blower delivers design airflow to each room.
- design temperature
- Related: Manual J load calculation, balance point
The outdoor winter and summer conditions a system is sized to handle, typically the 99 percent winter and 1 percent summer values for the location. Equipment capacity is matched to load at these points.
- superheat
- Related: subcooling, TXV
The number of degrees a refrigerant vapor is above its saturation temperature at a given pressure. Measured at the evaporator outlet, it confirms the expansion valve is feeding the coil properly.
- subcooling
- Related: superheat, TXV
The number of degrees a liquid refrigerant is below its saturation temperature at a given pressure. Measured at the condenser outlet, it indicates how much liquid is stacked in the condenser.
- TXV
- Related: superheat, subcooling
A thermostatic expansion valve that meters refrigerant into the evaporator and modulates flow to hold a set superheat. It responds to evaporator outlet temperature and pressure through a sensing bulb.
- balance point
- Related: design temperature, auxiliary heat
The outdoor temperature at which a heat pump's capacity exactly equals the building's heat loss. Below it, supplemental or backup heat must make up the difference.
- auxiliary heat
- Related: balance point, defrost cycle
Supplemental electric resistance or fossil-fuel heat that operates when a heat pump cannot meet the load, such as during defrost or below the balance point.
- defrost cycle
- Related: auxiliary heat, balance point
A timed or demand-initiated sequence that reverses refrigerant flow or stops the outdoor fan to melt frost from an outdoor coil, often energizing auxiliary heat to prevent cold blow.
- external static pressure
- Related: Manual D duct design, airflow
The resistance to airflow measured across the blower assembly, expressed in inches of water column. It is used with the fan performance table to confirm the system is moving design airflow.
- airflow
- Related: external static pressure, combustion air
The volume of air moved per unit time, usually cubic feet per minute. Correct airflow is required for capacity, efficiency, and safe combustion in fuel-burning equipment.
- combustion air
- Related: airflow, flue
Air supplied to a fuel-burning appliance for complete combustion and dilution of flue gases. It must be provided from outdoors or adequately sized openings per code.
- flue
- Related: combustion air, draft
The passage or vent that carries products of combustion from an appliance to the outdoors. Correct sizing, slope, and termination prevent spillage of carbon monoxide into the building.
- draft
- Related: flue, combustion air
The negative pressure that draws combustion gases up a vent or chimney. It can be natural, from buoyancy of hot gases, or mechanical, from an induced-draft fan.
- refrigerant recovery
- Related: recovery cylinder, refrigerant
Removing refrigerant from a system into a recovery cylinder or machine rather than venting it to the atmosphere. Federal law requires recovery before opening a circuit.
- refrigerant
- Related: refrigerant recovery, superheat
The working fluid in a refrigeration cycle that absorbs heat by evaporating at low pressure and rejects heat by condensing at high pressure. Handling is regulated by federal and state rules.
- recovery cylinder
- Related: refrigerant recovery, refrigerant
A DOT-approved, properly labeled vessel used to store recovered refrigerant. It must not be overfilled and must be evacuated before use.
- water hammer
- Related: backflow preventer, air gap
A banging noise and pressure surge caused by a sudden stop in water flow, such as a fast-closing valve. Arrestors or properly sized piping reduce the shock.
- backflow preventer
- Related: air gap, cross-connection
A device that prevents contaminated water from reversing into a potable supply due to backsiphonage or backpressure. Selection depends on the degree of hazard.
- air gap
- Related: backflow preventer, cross-connection
The vertical separation between a potable water outlet and the flood level rim of a receiving fixture. It is the most reliable form of backflow protection.
- cross-connection
- Related: backflow preventer, air gap
Any actual or potential link between a potable water system and a source of contamination or pollution. It must be eliminated or protected by an approved backflow device.
- hydronic loop
- Related: circulator pump, expansion tank
A closed piping circuit that circulates heated or chilled water between a boiler or chiller and terminal units such as baseboard, radiators, or fan coils.
- circulator pump
- Related: hydronic loop, expansion tank
A pump that moves water through a hydronic loop. It must be sized for the system's head loss and flow rate, and often uses a flanged or wet-rotor design.
- expansion tank
- Related: hydronic loop, circulator pump
A vessel that absorbs the volume change of water as it heats in a closed hydronic system, limiting pressure rise and protecting components from overpressure.
- trap seal
- Related: vent stack, water hammer
The water held in a plumbing trap that blocks sewer gas from entering a building. Its depth is set by code and must be maintained by proper venting.
- vent stack
- Related: trap seal, cross-connection
A vertical pipe that admits air to a drainage system and carries sewer gases to the outdoors, protecting trap seals from siphonage.
- ground fault circuit interrupter
- Related: equipment grounding conductor, overcurrent protection
A device that trips when it detects a small current imbalance between hot and neutral, protecting people from shock. Required in many wet and outdoor locations.
- equipment grounding conductor
- Related: ground fault circuit interrupter, bonding
The conductor that connects non-current-carrying metal parts of equipment to the grounding system, providing a low-impedance path for fault current.
- bonding
- Related: equipment grounding conductor, ground fault circuit interrupter
Electrically connecting metal parts to ensure they remain at the same potential, preventing shock and arcing. It is distinct from grounding to earth.
- overcurrent protection
- Related: disconnect, ground fault circuit interrupter
A fuse or circuit breaker that opens a circuit when current exceeds its rating, protecting conductors and equipment from overheating and fire.
- disconnect
- Related: overcurrent protection, lockout/tagout
A switch or device that opens all ungrounded conductors to an appliance, allowing it to be safely serviced. It must be located within sight and be properly rated.
- lockout/tagout
- Related: disconnect, overcurrent protection
A procedure that isolates and locks an energy source in the off position and tags it so equipment cannot be re-energized while someone is working on it.
- ampacity
- Related: overcurrent protection, voltage drop
The maximum current a conductor can carry continuously under stated conditions without exceeding its temperature rating. It determines wire size and breaker selection.
- voltage drop
- Related: ampacity, overcurrent protection
The loss of voltage along a conductor due to resistance, which increases with current and length. Excessive drop reduces motor performance and wastes energy.
- Ohio Construction Industry Licensing Board
- Related: Ohio Revised Code Chapter 4740, contractor license
The state board within the Ohio Department of Commerce that licenses HVAC, refrigeration, plumbing, hydronics, and electrical contractors and enforces Chapter 4740 requirements.
- Ohio Revised Code Chapter 4740
- Related: Ohio Construction Industry Licensing Board, continuing education
The Ohio statute governing licensing of construction contractors, including HVAC, refrigeration, plumbing, hydronics, and electrical trades, and the board that administers it.
- contractor license
- Related: Ohio Construction Industry Licensing Board, continuing education
A credential issued by the board authorizing a person or business to perform or offer licensed trade work in Ohio. It is required before contracting and must be renewed.
- continuing education
- Related: contractor license, Ohio Revised Code Chapter 4740
Required hours of approved instruction a licensee must complete each renewal cycle to maintain licensure and stay current on code and trade practice.
- qualifying individual
- Related: contractor license, Ohio Construction Industry Licensing Board
The licensed person whose credential supports a contracting business entity's registration and who is responsible for the work performed under that license.