Phius Certified Passive House Consultant (CPHC) flashcards
Phius Certified Passive House Consultant (CPHC) · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Treated floor area (TFA)
- The conditioned floor area used to normalize all Phius demand and load metrics. Only spaces inside the thermal and airtight boundary count, so zone boundaries must be drawn deliberately.
- Specific space heat demand
- Annual space-heating energy divided by treated floor area, in kWh/(m²·yr). It is a certification metric, distinct from peak load, and both must pass.
- Peak heating load
- The maximum heating power needed at design conditions, in W or W/m². A low peak load is what allows a passive building to omit a conventional central heating distribution system.
- n50 airtightness
- The air change rate at 50 Pa pressure difference, measured by blower door. Passive targets are typically n50 ≤ 0.6 h⁻¹ for the whole building.
- Linear thermal transmittance psi
- The heat loss per unit length per kelvin at a junction, in W/(m·K). Junction penalty equals psi times junction length and is added to the assembly UA.
- Continuous exterior insulation
- Insulation outside the structure that limits thermal bridging at studs and slabs and keeps the structural layer warm, raising the condensing surface above the interior dew point.
- Whole-window U-value
- The U-value of frame, spacer, edge, and glazing combined, not center-of-glass. It governs both heat loss and interior surface temperature, so it predicts condensation risk.
- Solar heat gain coefficient
- The fraction of incident solar radiation admitted through a window as heat. High values help in heating climates; low values with shading are needed to control cooling demand.
- Vapor retarder placement
- In cold climates the vapor retarder goes on the warm side; in mixed and warm-humid climates vapor-open assemblies control inward vapor drive from wet cladding.
- Slab edge thermal bridge
- The junction where a slab meets the foundation wall and exterior. Insulating the slab edge continuously reduces a bridge that can otherwise dominate the envelope UA.
- WUFI Passive assembly model
- A layered hygrothermal model of each envelope assembly, built from materials with thermal and moisture properties, then referenced by area in the whole-building energy balance.
- Zone classification
- Each modeled space is conditioned, unconditioned, or adjacent. Only conditioned treated floor area enters the demand metrics, so misclassification directly distorts results.
- Heat recovery efficiency
- The fraction of heat in exhaust air transferred to supply air, typically 75-85% for certified units. It is entered in the model and reduces ventilation heat loss.
- Shading factor
- A multiplier reducing solar gain through a window for overhangs, fins, and horizon obstructions. It is applied with the glazing g-value, not instead of it.
- Model sanity check
- Comparing predicted specific demand against assembly U-values and glazing area. An implausibly low result usually means an unmodeled zone or an incorrect area.
- As-built model update
- The certified model must match the constructed envelope, ventilation, and systems. Deviations found during construction require a documented model revision and resubmission.
- Balanced ventilation
- Supply and exhaust air volumes are equal, avoiding pressure differences that drive moist interior air into assemblies and increase infiltration losses through the envelope.
- Frost protection strategy
- A preheater, recirculating defrost damper, or supply-air tempering that prevents core icing in cold weather. The chosen strategy must be represented in the energy model.
- Duct location
- Ducts inside the conditioned envelope retain recovered heat. Ducts in attics or garages lose it, so they must be sealed and heavily insulated if unavoidable.
- Post-heater energy
- Energy used to temper ventilation supply air after recovery. It is allowed but counts against demand metrics, so the design aims to minimize it.
- Drain-water heat recovery
- A device recovering heat from warm wastewater to preheat domestic hot water. It reduces a load that becomes dominant once space conditioning is minimized.
- Cooking exhaust interlock
- A damper or control that balances high-rate kitchen exhaust against the HRV so the building does not depressurize and pull humid air into the envelope.
- Phius climate-specific limits
- Source energy and demand limits vary by climate zone. A design that passes in one location may fail in another because the limits change with climate.
- Source energy limit
- A cap on primary energy including grid and generation efficiency. All-electric heat-pump designs are favored, and on-site renewables can be credited against the limit.
- Certified passive house consultant
- A credentialed professional who prepares and submits the Phius energy model. The credential requires continuing education and cannot submit projects once lapsed.
- Performance versus prescriptive path
- The performance path uses the WUFI Passive model against numeric limits; prescriptive paths constrain assemblies and systems directly. Both can reach certification.
- Certificate issued to building
- Phius certification belongs to the specific constructed building, not to the designer. It follows verified airtightness and commissioning, not just a passing model.
- Blower-door test timing
- The test is run after the air barrier is complete but before finishes conceal it, so a failed result can still be corrected by sealing accessible leaks.
- Thermal imaging survey
- Infrared imaging during a blower-door test reveals missing insulation and air leaks. A temperature difference of at least about 10 K between inside and outside is needed.
- Ventilation commissioning
- Verification of design airflow at each terminal, supply-exhaust balance, and measured heat recovery efficiency. Results are recorded as part of the certification documentation.
- QA checklist sign-off
- A trade-by-trade record of envelope continuity, window installation, penetration sealing, and system commissioning, signed off before the work is concealed.
- Independent QA reviewer
- A reviewer separate from the design team who confirms the built building matches the certified model, using test reports, commissioning records, and photographs of concealed work.