Phius Certified Passive House Consultant (CPHC) key terms
Phius Certified Passive House Consultant (CPHC) · Get comfortable with the vocabulary.
- Passive building
- Related: Passive House (Passivhaus) standard, Thermal bridge
A design approach that keeps indoor comfort mostly through envelope quality, solar gain control, and fresh-air ventilation, so heating and cooling loads shrink to the point where conventional mechanical systems become unnecessary.
- Passive House (Passivhaus) standard
- Related: Passive building, Airtightness (n50), Primary energy
A performance-based building standard originating in Germany that sets limits on space heating and cooling demand, primary energy use, and airtightness, verified by modeling and on-site testing rather than prescriptive construction rules.
- Phius
- Related: Phius CORE, Phius ZERO, Phius Certified Passive House Consultant (CPHC)
A nonprofit organization that maintains and certifies a North American adaptation of the Passive House standard, offering climate-specific targets, certification of buildings and professionals, and quality assurance review of projects.
- Phius Certified Passive House Consultant (CPHC)
- Related: Phius, WUFI Passive, Phius Certification Guidebook
A professional credential issued by Phius after training and examination, showing competence in passive building design, WUFI Passive modeling, mechanical system design, and the Phius certification process.
- Phius CORE
- Related: Phius ZERO, Phius, Source energy
The baseline Phius certification path, requiring projects to meet climate-specific limits on heating and cooling demand, source energy, and airtightness while demonstrating cost-optimized envelope and system choices.
- Phius ZERO
- Related: Phius CORE, Renewable energy production, Source energy
A stricter Phius certification tier requiring all annual operational energy, including plug loads and appliances, to be offset by on-site renewable generation, on top of the CORE performance requirements.
- Phius Certification Guidebook
- Related: Phius, Quality assurance (QA) review, Phius CORE
The controlling document that defines Phius program requirements, submission stages, modeling conventions, documentation, and quality assurance obligations for a certified project or consultant.
- WUFI Passive
- Related: Phius Certification Guidebook, Thermal bridge, Specific heat demand
Whole-building energy and hygrothermal modeling software used for Phius projects, combining a monthly or dynamic energy balance with moisture transport analysis and reporting formatted for certification review.
- Specific heat demand
- Related: Specific cooling demand, Treated floor area (TFA), Phius CORE
Annual space heating energy per unit of treated floor area, usually expressed in kWh per square meter per year; a headline metric compared against a climate-specific limit for certification.
- Specific cooling demand
- Related: Specific heat demand, Latent load, Treated floor area (TFA)
Annual space cooling energy divided by treated floor area, reported in kWh per square meter per year and compared with a climate-specific cap that accounts for local dehumidification and solar loads.
- Treated floor area (TFA)
- Related: Specific heat demand, Conditioned space, Source energy
The conditioned floor area used as the denominator for intensity metrics, calculated by a defined rule set that excludes some unconditioned or unfinished spaces and includes interior wall footprints.
- Primary energy
- Related: Source energy, Primary energy renewable (PER), Phius CORE
Energy consumed at the source, including generation and delivery losses, calculated by multiplying delivered energy carriers by conversion factors; used to judge total building efficiency beyond heating and cooling alone.
- Source energy
- Related: Primary energy, Renewable energy production, Phius ZERO
A Phius metric that sums delivered energy across all end uses after applying site-to-source multipliers, allowing comparison of buildings that use different fuels or electricity grids.
- Primary energy renewable (PER)
- Related: Primary energy, Renewable energy production, Phius ZERO
An energy balance method that credits on-site or off-site renewable supply against demand, accounting for the timing and conversion losses of renewable generation and storage.
- Renewable energy production
- Related: Source energy, Phius ZERO, Primary energy renewable (PER)
Energy generated on the project site or procured from qualifying renewable sources, which may be credited against building demand under defined rules, typically limited to annual consumption.
- Thermal bridge
- Related: Thermal bridge-free construction, Psi-value, Continuous insulation
A localized path where heat flows more readily through the envelope than in adjacent assemblies, such as a slab edge or balcony penetration, raising heating demand and creating cold interior surfaces.
- Thermal bridge-free construction
- Related: Thermal bridge, Psi-value, Airtightness (n50)
A design goal in which structural penetrations and geometric junctions are detailed so that heat flow at those locations stays close to the surrounding assembly, eliminating condensation risk and demand penalties.
- Psi-value
- Related: Thermal bridge, Chi-value, Continuous insulation
The linear thermal transmittance of a junction, reported in watts per meter per kelvin, quantifying the extra heat flow per unit length of a thermal bridge beyond the clear wall area.
- Chi-value
- Related: Psi-value, Thermal bridge, WUFI Passive
The point thermal transmittance of a discrete penetration such as a bracket or bolt, expressed in watts per kelvin, used in modeling to account for localized heat flow that linear values miss.
- Continuous insulation
- Related: Thermal bridge, R-value, Thermal bridge-free construction
Insulation installed as an uninterrupted layer outside or around structural framing, reducing repeated thermal bridges and improving effective assembly performance compared with insulation placed only between studs.
- R-value
- Related: Continuous insulation, U-value, Thermal bridge
A material's resistance to conductive heat flow, expressed in area times temperature difference divided by heat flow; higher values mean better insulation, and assembly values must be adjusted for framing.
- U-value
- Related: R-value, Psi-value, Window U-value
The overall heat transfer coefficient of an assembly, equal to the inverse of its total resistance, describing how much heat passes per unit area and temperature difference.
- Window U-value
- Related: Solar heat gain coefficient (SHGC), U-value, Glazing ratio
The rate of heat loss through a whole window unit including frame, spacer, and glass, typically reported for a standard size and used as a primary input to envelope heat loss calculations.
- Solar heat gain coefficient (SHGC)
- Related: Window U-value, Glazing ratio, Overheating risk
The fraction of incident solar radiation admitted through a window as heat, combining directly transmitted and absorbed-then-released energy; it drives overheating risk and useful winter solar gains.
- Glazing ratio
- Related: Solar heat gain coefficient (SHGC), Overheating risk, Window U-value
The share of a wall or building facade area occupied by windows, used to balance useful daylight and winter solar gains against heat loss and summer overheating.
- Overheating risk
- Related: Solar heat gain coefficient (SHGC), Glazing ratio, Latent load
The likelihood that indoor temperatures exceed comfort thresholds during warm periods, assessed in modeling from solar gains, internal gains, ventilation rates, and the ability to purge heat.
- Airtightness (n50)
- Related: Blower door test, Thermal bridge-free construction, Vapor control layer
The measured air change rate of a building at a 50 pascal pressure difference, determined by blower door testing, used to limit infiltration heat loss and moisture-laden air movement.
- Blower door test
- Related: Airtightness (n50), Quality assurance (QA) review, Vapor control layer
A field test that pressurizes or depressurizes a building and measures leakage airflow, producing the n50 value and locating leaks for correction before certification.
- Vapor control layer
- Related: Hygrothermal analysis, Airtightness (n50), Thermal bridge
A material or coating that limits water vapor diffusion into an assembly, positioned by climate and assembly type so moisture can dry out and condensation stays within acceptable limits.
- Hygrothermal analysis
- Related: Vapor control layer, WUFI Passive, Thermal bridge
Simulation of heat and moisture transport through building assemblies over time, used to verify that condensation, mold growth, and freeze-thaw damage are avoided under real climate loads.
- Heat recovery ventilation (HRV)
- Related: Energy recovery ventilation (ERV), Ventilation efficiency, Balanced ventilation
A balanced mechanical ventilation system that transfers sensible heat from exhaust air to incoming outdoor air, providing fresh air without excessive heating energy in cold conditions.
- Energy recovery ventilation (ERV)
- Related: Heat recovery ventilation (HRV), Latent load, Balanced ventilation
A balanced ventilation system that transfers both sensible heat and moisture between exhaust and supply air, useful in humid climates where dehumidifying incoming air is costly.
- Ventilation efficiency
- Related: Heat recovery ventilation (HRV), Balanced ventilation, Specific heat demand
The fraction of heat in exhaust air that the recovery unit transfers to supply air, net of fan energy and defrost effects, used in modeling to compute ventilation heat loss.
- Balanced ventilation
- Related: Heat recovery ventilation (HRV), Ventilation efficiency, Makeup air
A ventilation strategy that supplies and exhausts equal air volumes through ducted fans, controlling where air enters and leaves so that fresh air reaches occupied rooms and moisture is removed at source.
- Makeup air
- Related: Balanced ventilation, Latent load, Airtightness (n50)
Outdoor air supplied to replace air removed by exhaust systems such as kitchen or bath fans, which must be planned so pressure imbalances and backdrafting do not undermine ventilation and combustion safety.
- Latent load
- Related: Energy recovery ventilation (ERV), Specific cooling demand, Overheating risk
The energy needed to remove moisture from air through condensation or desiccant processes, distinct from sensible cooling, and a major design driver in humid climates.
- Conditioned space
- Related: Treated floor area (TFA), Thermal bridge-free construction, Balanced ventilation
The part of a building intentionally heated or cooled to stay within comfort ranges, defining the boundary of the thermal envelope and the area counted in energy metrics.
- Quality assurance (QA) review
- Related: Phius Certification Guidebook, Blower door test, Phius
The Phius process in which submitted models, drawings, and test results are checked against program requirements by reviewers, with corrections required before certification is granted.