LEW key terms
LEW · Get comfortable with the vocabulary.
- Ohm's law
- Related: Series circuit, Parallel circuit, Voltage drop
The fixed relationship in a DC circuit where voltage equals current multiplied by resistance. Knowing any two values lets you calculate the third, making it the basis for predicting circuit behavior and verifying measurements.
- Series circuit
- Related: Parallel circuit, Ohm's law
A circuit with a single current path, so the same current flows through every component while voltage divides in proportion to resistance. Total resistance is the sum of individual resistances, and one open stops all current.
- Parallel circuit
- Related: Series circuit, Ohm's law
A circuit where components connect across the same two nodes, so voltage is common and current divides among branches. Total resistance is always lower than the smallest branch resistance, and one branch can fail without stopping others.
- Voltage drop
- Related: Ohm's law, Ampacity, Conductor sizing
The loss of potential along conductors carrying current, caused by conductor resistance. Excessive drop at the load causes dim lights, overheated motors, and poor equipment performance, so code limits it on feeders and branch circuits.
- Power factor
- Related: Apparent power, Transformer kVA rating
The ratio of real power in watts to apparent power in volt-amperes in an AC circuit. A low value means more current for the same useful work, increasing conductor and transformer loading and often triggering utility penalties.
- Apparent power
- Related: Power factor, Transformer kVA rating
The total power supplied to an AC load, measured in volt-amperes as the product of RMS voltage and RMS current without regard to phase angle. Sizing of conductors, transformers, and generators depends on it.
- Conductor ampacity
- Related: Conductor sizing, Ambient temperature correction, Voltage drop
The maximum continuous current a conductor can carry under stated conditions without exceeding its temperature rating. It depends on material, size, insulation, ambient temperature, and the number of current-carrying conductors bundled together.
- Conductor sizing
- Related: Conductor ampacity, Ambient temperature correction, Voltage drop
Selecting conductor cross-sectional area so ampacity after adjustment and correction is at least the required load current, while also satisfying voltage drop, short-circuit withstand, and terminal temperature limits.
- Ambient temperature correction
- Related: Conductor ampacity, Conductor sizing
An adjustment applied to a conductor's tabulated ampacity when the surrounding air or soil is hotter than the rating basis, because higher ambient temperature reduces the allowable current before insulation damage occurs.
- Box fill
- Related: Junction box, Conductor ampacity
The required internal volume of an outlet, junction, or device box based on counting each conductor, device, fitting, and grounding conductor at specified volumes. Undersized boxes overheat conductors and damage insulation during folding.
- Cable tray
- Related: Conductor ampacity, Raceway
A support system of rails and rungs that carries and routes cables, often permitting easier additions than conduit. Its use requires attention to fill, securement, and derating for bundled conductors.
- Raceway
- Related: Cable tray, Box fill
An enclosed channel such as conduit, tubing, or duct designed expressly for holding wires, cables, or busbars. Fill limits and bend radius rules keep conductors from jamming and insulation from damage during pulling.
- Overcurrent
- Related: Overload, Short circuit, Overcurrent protective device
Any current exceeding the rated current of equipment or the ampacity of a conductor, whether from overload, short circuit, or ground fault. Protective devices must clear it before thermal or mechanical damage occurs.
- Overload
- Related: Overcurrent, Short circuit, Motor overload protection
A current above normal full-load value that flows in an otherwise healthy circuit, typically gradual and small in magnitude. Motors and conductors heat over time, so overload protection responds with a time delay.
- Short circuit
- Related: Overcurrent, Ground fault, Interrupting rating
An unintended low-impedance connection between energized conductors or between an energized conductor and ground, producing very high current. Protective devices must interrupt it quickly, and equipment must withstand the magnetic and thermal stress.
- Ground fault
- Related: Short circuit, Equipment grounding conductor, Ground-fault circuit interrupter
Unintended current flowing from an energized conductor to normally non-current-carrying metal parts or earth. It may be low enough to escape a standard breaker, so sensitive detection or equipment grounding is essential to clear it safely.
- Overcurrent protective device
- Related: Interrupting rating, Overcurrent, Coordination
A fuse or circuit breaker intended to open a circuit automatically when current exceeds a set value for a set time. Its rating, trip curve, and interrupting capacity must match the circuit and available fault current.
- Interrupting rating
- Related: Overcurrent protective device, Short circuit, Coordination
The maximum short-circuit current a protective device can safely interrupt at its rated voltage. If available fault current exceeds it, the device may fail violently instead of clearing the fault.
- Coordination
- Related: Overcurrent protective device, Interrupting rating
Selecting protective device ratings and trip characteristics so that the device nearest a fault opens first, limiting outage scope. It requires comparing time-current curves and may conflict with the need for fast overall clearing.
- Equipment grounding conductor
- Related: Ground fault, Bonding, Grounding electrode system
The conductor that connects exposed metal enclosures and equipment frames to the system grounding point, providing a low-impedance path for fault current so protective devices operate promptly.
- Bonding
- Related: Equipment grounding conductor, Grounding electrode system
The permanent joining of metal parts to form an electrically conductive path that ensures electrical continuity and capacity to conduct any likely fault current safely.
- Grounding electrode system
- Related: Equipment grounding conductor, Bonding
The set of electrodes, such as rods, plates, pipes, or concrete-encased electrodes, that connects the electrical system to earth. It stabilizes voltage to ground and helps dissipate lightning and surge energy.
- Motor overload protection
- Related: Overload, Motor starter, Service factor
A device or relay that senses motor current and opens the control circuit when sustained current exceeds a set level, protecting windings from overheating caused by mechanical overload, low voltage, or single phasing.
- Motor starter
- Related: Motor overload protection, Locked-rotor current
An assembly combining a contactor for switching motor current with overload protection and control logic. It starts and stops the motor remotely and prevents restart after an overload trip until reset.
- Service factor
- Related: Motor overload protection, Locked-rotor current
A multiplier indicating how much a motor may exceed its nameplate horsepower continuously under rated conditions without damage. It is used to set overload protection and to judge acceptable loading.
- Locked-rotor current
- Related: Motor starter, Voltage drop
The current a motor draws at rated voltage with the rotor stationary, typically several times full-load current. It determines branch-circuit and controller sizing and influences voltage sag during starting.
- Transformer kVA rating
- Related: Apparent power, Power factor, Derating
The apparent power a transformer can deliver continuously without exceeding its temperature rise limit. It is set by winding and cooling design and must be matched to the connected load's total volt-amperes.
- Derating
- Related: Transformer kVA rating, Conductor ampacity, Ambient temperature correction
Reducing a device's allowable load or a conductor's ampacity because of adverse conditions such as high ambient temperature, altitude, harmonics, or enclosure confinement. It preserves insulation life and prevents nuisance tripping.
- Harmonics
- Related: Derating, Power factor
Voltages or currents at integer multiples of the fundamental frequency, produced mainly by electronic power supplies and variable-speed drives. They heat neutral conductors and transformer cores and distort waveform quality.
- Arc flash
- Related: Lockout/tagout, Limited approach boundary
A dangerous release of energy caused by an electric arc between conductors or from conductor to ground. It produces intense heat, blast pressure, and molten metal, so energized work requires assessment and appropriate protective equipment.
- Lockout/tagout
- Related: Arc flash, Voltage verification
A procedure that isolates energy sources, applies locks and tags, and verifies de-energization before work begins, preventing unexpected energization or release of stored energy such as capacitor charge.
- Limited approach boundary
- Related: Arc flash, Lockout/tagout
A distance from exposed energized parts that unqualified persons must not cross unless escorted and protected. It helps plan work so that shock risk is controlled by distance, barriers, and personal protective equipment.
- Voltage verification
- Related: Lockout/tagout, Continuity test
Confirming a circuit is de-energized with a tester proven functional on a known live source before and after the test. This step guards against meter failure and misidentified circuits.
- Continuity test
- Related: Voltage verification, Megohmmeter test
A de-energized check using a meter or signal source to confirm a low-resistance path exists through conductors, switches, or connections, verifying integrity where full current cannot be applied.
- Megohmmeter test
- Related: Continuity test, Ground fault
An insulation resistance measurement made with a high DC test voltage to detect moisture, contamination, or degradation in insulation. Readings are compared over time and corrected for temperature and humidity.
- Ground-fault circuit interrupter
- Related: Ground fault, Equipment grounding conductor
A device that compares current leaving and returning through a circuit and trips when the imbalance indicates leakage to ground, protecting people from shock in wet or otherwise hazardous locations.