Mistake 1

Treating a whole-building energy model as a single pass: selecting equipment and envelope values first, then running the simulation once at the end and reporting whatever number it produces.

Candidates carry over a linear design workflow from practice and underestimate how much the exam tests iterative, calibration-driven modeling; they also run out of time and cut the iteration loop.

What to do instead

Practice a fixed loop: baseline model, sensitivity check on the dominant loads, targeted parameter changes, re-run, and document the delta. Build a habit of stating which parameter moves which end use before touching the model.

Mistake 2

Reporting a single annual energy number with no statement of weather file, simulation engine, or assumptions, and comparing that number directly against a benchmark from a different basis (site vs source, conditioned vs gross floor area).

The benchmark and the model look numerically compatible, so unit and boundary mismatches go unnoticed; candidates also assume all kWh are interchangeable.

What to do instead

Always normalize explicitly: state energy basis, area basis, and weather data set before comparing. Convert site to source with a stated factor and re-express intensity on the same floor-area definition as the benchmark.

Mistake 3

Answering indoor air quality questions by picking the ventilation rate that 'feels adequate' instead of distinguishing the ventilation-rate procedure from the indoor air quality procedure and applying the correct one to the scenario.

Both procedures appear in guidance and candidates conflate them, or they default to the familiar prescriptive rate even when the question describes a performance-based design.

What to do instead

For each IAQ item, first classify the question as prescriptive rate, performance-based contaminant control, or source control. Then apply only the method matching that classification and show the governing criterion (rate, concentration limit, or exposure).

Mistake 4

Confusing thermal comfort variables: mixing operative temperature with air temperature, ignoring mean radiant temperature in a radiant or glazed-perimeter scenario, and applying the wrong metabolic rate or clothing level.

Simplified rules of thumb collapse several variables into one, and candidates memorize a single comfort zone rather than the underlying variable set.

What to do instead

Before answering, list the six comfort variables and mark which ones the scenario fixes and which it leaves open. If radiant asymmetry or a large glazed area is described, compute or reason with operative temperature rather than dry-bulb.

Mistake 5

Designing a commissioning scope that starts at functional performance testing, omitting owner's project requirements, basis of design, and pre-functional checks.

Candidates equate commissioning with the test at the end and skip the documentation chain that makes the test meaningful.

What to do instead

Structure every commissioning answer along the full sequence: OPR, BOD, design review, submittal review, pre-functional checks, functional performance tests, seasonal/deferred testing, and systems manual with training. Name the phase before naming the activity.

Mistake 6

Treating retro-commissioning and ongoing commissioning as identical to initial commissioning, and failing to identify the persistence mechanism that keeps savings from decaying.

The activities overlap in name and method, so candidates reuse the new-building answer; they also overlook monitoring-based or ongoing verification.

What to do instead

Tag each question by life-cycle stage (new, existing, ongoing) and answer with the stage-specific deliverable. For existing buildings, always include a monitoring-based or periodic re-verification element to address savings persistence.

Mistake 7

Choosing a water-efficiency strategy by fixture type alone without checking the connected-load and end-use breakdown, so irrigation or cooling-tower makeup dominates and the fixture savings are irrelevant.

Fixtures are the most familiar category, so candidates reach for them first instead of quantifying where water actually goes.

What to do instead

Start every water item with an end-use inventory (fixtures, irrigation, cooling, process). Target the largest end use, then state the metric used (liters per fixture use, irrigation demand vs. collection, cycles of concentration).

Mistake 8

Selecting materials on a single attribute such as recycled content while ignoring life-cycle tradeoffs, durability, or the functional unit the comparison is based on.

Single-attribute claims are easy to recall and appear in marketing material, so they substitute for a comparative life-cycle basis.

What to do instead

Force a functional-unit comparison: state the service delivered, the service life, and at least two impact categories before recommending a material. Reject single-attribute claims unless the question explicitly scopes to that attribute.

Mistake 9

Applying a high-performance envelope or glazing target without checking the climate zone and orientation interaction, so a measure appropriate in one climate is transferred unchanged to another.

Candidates memorize measure lists rather than the load-driver logic behind them, and climate-zone-dependent answers look interchangeable.

What to do instead

For each envelope or passive item, name the climate zone and the dominant load (heating, cooling, or both) before selecting the measure. Check orientation-specific solar control separately from whole-envelope U-value.

Mistake 10

Under-allocating time to unit-bearing calculations and multi-part scenario questions, leaving them to the end and answering from memory instead of computing.

Candidates pace themselves on recall-style items and are surprised by the proportion of quantitative and combined-concept questions.

What to do instead

Do a timed practice set and set a per-question budget. Flag any item requiring a calculation, complete all calculations in one dedicated pass, and verify units and significant figures before moving on.