ASHRAE HBDP study materials
ASHRAE HBDP study resources

ASHRAE HBDP key terms

ASHRAE HBDP · Get comfortable with the vocabulary.

Whole-Building Energy Simulation

Computer modeling of a building's annual energy use by calculating heat flows, equipment performance, and schedules hour by hour. Designers use it to compare options and demonstrate compliance with performance-based codes.

Related: Calibration (Energy Model), Baseline Building Model, Weather File (TMY)
Baseline Building Model

A reference model representing the minimum code-compliant design, against which a proposed design is compared to show percentage energy savings. It must use the same geometry, schedules, and weather data as the proposed model.

Related: Whole-Building Energy Simulation, Energy Use Intensity
Calibration (Energy Model)

Adjusting model inputs so simulated energy use closely matches measured utility data for an existing building. Calibration supports retrofit decisions and measurement-and-verification baselines.

Related: Whole-Building Energy Simulation, Measurement and Verification
Energy Use Intensity

Annual energy consumed per unit of floor area, typically expressed in kBtu per square foot or kWh per square meter. It normalizes consumption across buildings and supports benchmarking.

Related: Energy Benchmarking, Baseline Building Model
Energy Benchmarking

Comparing a building's energy performance against similar buildings or a national database using normalized metrics. Results identify poor performers and prioritize retrofit investment.

Related: Energy Use Intensity, Retrocommissioning
Weather File (TMY)

A typical meteorological year dataset of hourly temperature, humidity, and solar radiation for a location. Energy simulations use it to represent long-term average climate conditions.

Related: Whole-Building Energy Simulation, Heating Degree-Day
Heating Degree-Day

A climate index summing, over a season, the degrees by which daily mean outdoor temperature falls below a reference base. It estimates heating loads and supports simplified energy comparisons.

Related: Weather File (TMY), Cooling Degree-Day
Cooling Degree-Day

A climate index summing, over a season, the degrees by which daily mean outdoor temperature exceeds a reference base. It estimates cooling loads and supports simplified energy comparisons.

Related: Heating Degree-Day, Weather File (TMY)
Passive Design

Shaping building form, orientation, envelope, and shading so that heating, cooling, and daylighting needs are reduced before active systems are sized. It lowers loads rather than adding equipment efficiency.

Related: Load Reduction, Thermal Mass, Daylighting
Load Reduction

Lowering peak and annual heating, cooling, and lighting demands through envelope, shading, and internal-load strategies. Smaller loads allow smaller, less costly mechanical systems.

Related: Passive Design, Envelope Thermal Performance
Envelope Thermal Performance

How well the building skin resists heat flow, described by insulation level, glazing properties, airtightness, and thermal bridging. Strong performance reduces heating and cooling loads.

Related: Thermal Bridge, Window-to-Wall Ratio, Load Reduction
Thermal Bridge

A path of high-conductance material that bypasses insulation, such as a balcony slab or steel stud. It causes localized heat loss, cold surfaces, and possible condensation.

Related: Envelope Thermal Performance, Continuous Insulation
Continuous Insulation

Insulation placed outside the structural frame so it covers studs, slabs, and other penetrations without interruption. It reduces thermal bridging and improves effective R-value.

Related: Thermal Bridge, Envelope Thermal Performance
Window-to-Wall Ratio

The area of glazing divided by the gross above-grade wall area of a facade. It strongly influences daylight, solar gain, and envelope heat loss, so codes often cap it.

Related: Envelope Thermal Performance, Daylighting, Solar Heat Gain Coefficient
Solar Heat Gain Coefficient

The fraction of incident solar radiation admitted through glazing as heat, including absorbed and re-radiated energy. Lower values reduce cooling loads in sunny climates.

Related: Window-to-Wall Ratio, Shading Coefficient
Shading Coefficient

The ratio of solar heat gain through a given glazing assembly to that through clear single glazing under identical conditions. It predates and relates numerically to solar heat gain coefficient.

Related: Solar Heat Gain Coefficient, Daylighting
Thermal Mass

The capacity of building materials to store and later release heat, moderating indoor temperature swings. Exposed masonry or concrete can shift peak cooling loads to later hours.

Related: Passive Design, Load Reduction
Daylighting

Using controlled natural light to illuminate interior spaces and reduce electric lighting energy. Success depends on aperture design, glare control, and automatic dimming.

Related: Window-to-Wall Ratio, Daylight Autonomy, Glare
Daylight Autonomy

The percentage of occupied hours when a space reaches a target illuminance from daylight alone. It quantifies daylight sufficiency and supports lighting power reductions.

Related: Daylighting, Glare
Glare

Excessive or poorly distributed brightness that causes discomfort or reduces visibility. Daylighting design controls it with shading, light shelves, and appropriate surface luminance.

Related: Daylighting, Daylight Autonomy
Thermal Comfort

The condition of mind expressing satisfaction with the thermal environment, influenced by air temperature, radiant temperature, humidity, air speed, clothing, and activity. Standards define acceptable ranges.

Related: Predicted Mean Vote, Operative Temperature
Predicted Mean Vote

A comfort index predicting the average thermal sensation of a large occupant group on a scale from cold to hot. It pairs with predicted percentage dissatisfied to judge acceptability.

Related: Thermal Comfort, Operative Temperature
Operative Temperature

A single temperature combining air temperature and mean radiant temperature, weighted by air speed. It better represents occupant thermal sensation than dry-bulb air temperature alone.

Related: Thermal Comfort, Predicted Mean Vote
Ventilation Rate

The volumetric flow of outdoor air supplied to a space per unit time or per person and floor area. Adequate rates dilute contaminants and support occupant health and productivity.

Related: Demand-Controlled Ventilation, Indoor Air Quality
Demand-Controlled Ventilation

Modulating outdoor-air supply based on measured occupancy, often via carbon dioxide sensors, rather than running at design flow continuously. It saves fan and conditioning energy while protecting air quality.

Related: Ventilation Rate, Indoor Air Quality, Carbon Dioxide Monitoring
Carbon Dioxide Monitoring

Measuring indoor carbon dioxide concentration as an indicator of occupancy and ventilation adequacy. Rising levels signal stale air or insufficient outdoor-air delivery.

Related: Demand-Controlled Ventilation, Indoor Air Quality
Indoor Air Quality

The condition of air inside a building as it affects occupant health and comfort, shaped by pollutant sources, ventilation, filtration, and moisture control. Poor quality causes complaints and lost productivity.

Related: Ventilation Rate, Volatile Organic Compound, Demand-Controlled Ventilation
Volatile Organic Compound

Carbon-based chemicals that readily evaporate at room temperature, emitted by adhesives, coatings, and furnishings. Many irritate occupants, so low-emitting materials are specified.

Related: Indoor Air Quality, Material Emissions
Material Emissions

Release of gases or particles from building products into indoor air over time. Specification of low-emitting products and flush-out procedures reduces occupant exposure.

Related: Volatile Organic Compound, Indoor Air Quality
Commissioning

A quality-focused process verifying that building systems are designed, installed, and operate to meet the owner's requirements. It begins in design and continues through handover and warranty.

Related: Functional Performance Test, Retrocommissioning, Measurement and Verification
Functional Performance Test

A documented procedure that exercises a system under simulated conditions to confirm it responds correctly and meets specified performance. Results are recorded and deficiencies tracked to closure.

Related: Commissioning, Controls Sequence Verification
Retrocommissioning

Applying the commissioning process to an existing building that was never commissioned, to identify and correct operational deficiencies. It typically delivers low-cost energy savings.

Related: Commissioning, Energy Benchmarking
Measurement and Verification

A structured method for quantifying savings from efficiency measures by comparing measured post-installation energy use with an adjusted baseline. It supports performance guarantees and persistence tracking.

Related: Calibration (Energy Model), Commissioning
Controls Sequence Verification

Confirming that control logic, setpoints, and interlocks operate as written in the sequence of operations. Discrepancies are common causes of excess energy use.

Related: Functional Performance Test, Commissioning
Water Use Intensity

Annual potable water consumption per unit of floor area or per occupant, used to compare buildings and track conservation results. It supports benchmarking and code compliance.

Related: Water Balance (Building), Nonpotable Water Reuse
Nonpotable Water Reuse

Using treated or captured water such as rainwater, greywater, or condensate for non-drinking purposes like flushing and irrigation. It reduces potable demand and site runoff.

Related: Water Use Intensity, Water Balance (Building)
Water Balance (Building)

An accounting of all water entering, leaving, and being stored within a building or site, including supply, reuse, and discharge. It sizes reuse systems and verifies conservation goals.

Related: Nonpotable Water Reuse, Water Use Intensity
Life-Cycle Assessment

A method quantifying environmental impacts of materials and systems from extraction through disposal across defined stages. It informs comparisons among design alternatives beyond operating energy.

Related: Embodied Carbon, Material Emissions
Embodied Carbon

Greenhouse gas emissions associated with extracting, manufacturing, transporting, installing, and disposing of building materials. It complements operational emissions in whole-life carbon accounting.

Related: Life-Cycle Assessment, Material Emissions