CA C-20 HVAC key terms
CA C-20 HVAC · Get comfortable with the vocabulary.
- Load Calculation
- Related: Takeoff, Manual D Duct Sizing
A room-by-room estimate of the heat a building gains and loses at design conditions, based on insulation, windows, occupancy, and outdoor temperature. Contractors use it to choose equipment size and to plan ductwork.
- Takeoff
- Related: Load Calculation
A counted list of materials taken from the plans - feet of duct, number of fittings, pipe and refrigerant line lengths, and equipment - used to price labor and material for a bid.
- Manual D Duct Sizing
- Related: Equivalent Length, Static Pressure, Air Balancing
An accepted residential duct design method that matches the blower's available static pressure to the friction loss of the longest run plus its fittings, so every outlet receives its design airflow.
- Equivalent Length
- Related: Manual D Duct Sizing, Static Pressure
The resistance of an elbow, tee, or transition expressed as the length of straight duct that would cause the same pressure drop. It is added to measured length when sizing a run.
- Static Pressure
- Related: Manual D Duct Sizing, Air Balancing
The outward push of air against duct walls, measured in inches of water column. Supply and return readings across a fan show how hard the blower is working against the system.
- Plenum
- Related: Air Balancing
A sheet metal or factory-built chamber connected to the supply or return side of an air handler. Supply plenums split airflow into branch ducts; return plenums gather air from several grilles.
- Air Balancing
- Related: Static Pressure, Manual D Duct Sizing
Adjusting volume dampers, registers, and fan speed until measured airflow at each outlet matches the design quantities, confirming the installed duct system performs as the load and duct design assumed.
- Superheat
- Related: Subcooling, Thermostatic Expansion Valve (TXV)
The number of degrees by which a refrigerant vapor is warmer than its saturation temperature at the same pressure. Technicians use it to judge whether the evaporator is getting the correct refrigerant flow.
- Subcooling
- Related: Superheat, Saturation Temperature
The number of degrees by which a liquid refrigerant is cooler than its saturation temperature at the same pressure. Measured at the condenser outlet, it indicates how much liquid refrigerant is backed up in the condenser.
- Saturation Temperature
- Related: Superheat, Subcooling
The temperature at which a refrigerant changes between liquid and vapor at a given pressure. Because it moves with pressure, a gauge reading can be converted to a temperature on a pressure-temperature chart.
- Sensible Heat
- Related: Latent Heat
Heat added to or removed from a substance that changes its temperature but not its state, such as air warming as it crosses a heat exchanger.
- Latent Heat
- Related: Sensible Heat
Heat absorbed or released when a substance changes state at constant temperature, such as refrigerant boiling in an evaporator or water vapor condensing on a cold coil.
- Thermostatic Expansion Valve (TXV)
- Related: Superheat, Saturation Temperature
A modulating metering device that regulates refrigerant flow into the evaporator by balancing a sensing bulb, evaporator pressure, and a spring, holding superheat nearly constant as the load changes.
- Reversing Valve
- Related: Defrost Cycle, Balance Point
A four-way solenoid valve that redirects compressor discharge and suction gas so the indoor and outdoor coils swap roles, letting a heat pump heat or cool.
- Balance Point
- Related: Auxiliary Heat, Defrost Cycle
The outdoor temperature at which heat pump capacity equals the building's heat loss. Below that temperature the heat pump cannot keep up and supplemental heat must make up the difference.
- Auxiliary Heat
- Related: Balance Point, Sequencer
Supplemental electric resistance or gas heat that operates along with the heat pump when outdoor air falls below the balance point or while the unit is in defrost.
- Defrost Cycle
- Related: Reversing Valve, Auxiliary Heat
A control-initiated period in which a heat pump melts frost from the outdoor coil, usually by temporarily reversing to cooling mode while the outdoor fan stops or slows.
- Coefficient of Performance (COP)
- Related: Balance Point
The ratio of heating or cooling delivered to the energy consumed, expressed in matching units. A COP of 3 means three units of heat move for each unit of electricity used.
- Combustion Air
- Related: California Mechanical Code
Air provided to a gas appliance for burning fuel and for diluting flue gases. Codes require permanent openings or ducts sized to the appliance input rating, and louvers must stay clear.
- Contactor
- Related: Locked Rotor Amps, Ohm's Law
A relay with a low-voltage coil and heavy line-voltage contacts that switches power to a compressor, fan motor, or heater bank when the thermostat or control board calls.
- Run Capacitor
- Related: Start Capacitor, Locked Rotor Amps
A capacitor connected continuously in the circuit of a permanent split capacitor motor, shifting current in the start winding to improve running torque and efficiency.
- Start Capacitor
- Related: Run Capacitor, Potential Relay
A large-microfarad capacitor switched into the circuit only during motor startup to increase starting torque, then removed by a relay once the motor approaches operating speed.
- Locked Rotor Amps (LRA)
- Related: Contactor, Run Capacitor
The current a motor draws when its rotor cannot turn. Comparing a measured reading to the nameplate value helps identify a seized compressor or a failed start component.
- Potential Relay
- Related: Start Capacitor, Run Capacitor
A voltage-sensing relay whose coil is wired across the compressor start winding; rising back EMF as the motor speeds up opens the contacts and removes the start capacitor.
- Sequencer
- Related: Auxiliary Heat, Contactor
A time-delay control that energizes electric resistance heating elements one at a time and delays the blower, limiting the current surge and clearing residual heat at shutdown.
- Heat Anticipator
- Related: Contactor
A small adjustable heater inside a mechanical thermostat that warms the bimetal element so its contacts open slightly before the room reaches setpoint, reducing temperature overshoot.
- Ohm's Law
- Related: Contactor, Locked Rotor Amps (LRA)
The fixed relationship in which voltage equals current multiplied by resistance. Technicians use it to predict expected amp and ohm readings when troubleshooting motors and control circuits.
- Nitrogen Purge
- Related: Brazing
A slow flow of dry nitrogen through piping while it is being brazed, which displaces oxygen and prevents black oxide scale from forming inside the tubing.
- Brazing
- Related: Nitrogen Purge, Flare Fitting
Joining copper tubing with a filler alloy that melts above 840 degrees F but below the melting point of the base metal; capillary action draws filler into a cleaned, properly heated joint.
- Flare Fitting
- Related: Brazing
A connection made by swaging the end of soft copper into a cone that seals against a matching seat on a brass fitting, common on mini-splits and some residential line sets.
- Refrigerant Recovery
- Related: Leak Detection, Weigh-In Method
Transferring refrigerant from a system into a recovery cylinder instead of venting it to the atmosphere, as federal rules require, so it can be reused, recycled, or reclaimed.
- Micron
- Related: Standing Vacuum Test
A unit of length equal to one thousandth of a millimeter, used on vacuum gauges. A reading of 500 microns or lower that holds steady shows a dry, leak-free system.
- Standing Vacuum Test
- Related: Micron, Leak Detection
Closing the valve to the vacuum pump after evacuation and watching the micron gauge; a slow rise suggests moisture boiling off, while a fast rise points to a leak.
- Weigh-In Method
- Related: Subcooling, Superheat
Charging refrigerant by weight on a scale using the nameplate charge plus allowances for line-set length; it is the most accurate method for fixed-orifice systems.
- Leak Detection
- Related: Standing Vacuum Test, Refrigerant Recovery
Locating refrigerant loss with electronic detectors, fluorescent dye, nitrogen pressure tests, or soap bubbles, performed before recharging so the repair is not wasted.
- Preventive Maintenance
- Related: Leak Detection
Scheduled service such as coil cleaning, belt and bearing checks, filter changes, electrical measurements, and charge verification that keeps equipment efficient and prevents breakdowns.
- Lockout/Tagout
- Related: Contactor
A safety procedure in which the disconnect is opened, locked, and tagged by the person working on the equipment so power cannot be restored unexpectedly while work is underway.
- California Mechanical Code
- Related: Combustion Air
The state-adopted mechanical code governing HVAC installation in California, including equipment clearances, ventilation, combustion air, and venting requirements for permitted work.