CDFOM study materials
CDFOM study resources

CDFOM study plan

CDFOM · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

Data Centre Operations Management (operational processes, service level and KPI management)

  • Map the full set of operational processes a data centre runs on (incident, change, problem, capacity, asset, access) and write a one-line purpose and owner for each

  • Distinguish SLAs, SLRs, OLAs and underpinning contracts, and explain in your own notes how each is used to manage a service provider

  • Define at least 12 operational KPIs with formula, data source, target and escalation trigger for each

  • Draft a one-page monthly service review agenda that a facility manager would actually run with a client

Your checkpoint

A two-page operations reference sheet: process table, SLA/OLA comparison, and a 12-KPI register with formulas and thresholds

Week 2

Data Centre Operations Management (operational processes, service level and KPI management) & Facilities Management and Maintenance (planned and corrective maintenance, maintenance contracts)

  • Build a 12-month planned maintenance calendar covering electrical, mechanical, fire, security and building fabric systems, noting typical frequencies for each

  • Explain the difference between planned, corrective, predictive and reactive maintenance and justify which work types can be deferred and which cannot

  • Draft the key clauses you would insist on in a maintenance contract: scope, response and fix times, spares, reporting, escalation, penalties, exit

  • Describe how a maintenance activity is risk-assessed and approved before it starts, including permit-to-work and change linkage

Your checkpoint

A maintenance calendar plus a one-page maintenance contract clause checklist with at least 10 must-have clauses

Week 3

Facilities Management and Maintenance (planned and corrective maintenance, maintenance contracts)

  • Walk through the standard maintenance routines for UPS, generators, switchgear, chillers, CRAC/CRAH units and fire suppression, listing what is checked and why it matters

  • Explain how to manage a maintenance contractor on site: induction, supervision, sign-off, defect logging and closure

  • Design a defect and asset register structure that links every asset to its maintenance plan, criticality rating and spares holding

  • Set up a simple MTTR and PM compliance tracking method you could run in a spreadsheet

Your checkpoint

An asset criticality and maintenance matrix covering at least 15 asset types with frequency, owner and spares note

Week 4

Safety, Security and Environmental Management (physical security, health and safety, environmental controls)

  • Layer a physical security model: perimeter, building, data hall, rack, and describe controls at each layer including access control, CCTV and visitor management

  • List the health and safety hazards specific to a live data centre and the control for each: arc flash, battery acid, refrigerant, noise, confined space, manual handling, working at height

  • Explain environmental monitoring parameters (temperature, humidity, particulate, differential pressure) and how alarms are escalated and acted on

  • Describe fire detection and suppression approaches and the operational rules that apply during and after a discharge

Your checkpoint

A security and safety control matrix mapping each layer or hazard to its control, monitoring method and responsible role

Week 5

Staffing, Training and Competence Management (organisation, roles, shift operations)

  • Design a staffing model for a 24x7 facility: shift pattern, headcount maths including relief factor, and which roles must be on site versus on call

  • Write role profiles for facility technician, shift lead, security officer and facility manager with clear decision authority

  • Build a competence and authorisation framework: what training, assessment and re-certification each role needs before working unsupervised

  • Draft a shift handover procedure and an escalation matrix with named decision rights

Your checkpoint

A staffing and competence pack: headcount calculation, four role profiles and a shift handover template

Week 6

Governance, Compliance and Risk Management (standards, audits, documentation, risk)

  • Map the standards and frameworks relevant to data centre operations and explain what each actually requires in practice

  • Design a documentation and records control scheme: which documents are controlled, retention periods, review cycle and access rules

  • Build a risk register with likelihood, impact, owner, mitigation and residual rating for at least 10 realistic operational risks

  • Plan an internal audit cycle with scope, sampling approach, findings grading and corrective action tracking

Your checkpoint

A risk register with 10 scored risks plus an audit and corrective action tracker template

Week 7

Capacity, Availability and Continuity Management (capacity planning, resilience, emergency response) & Data Centre Operations Management (operational processes, service level and KPI management)

  • Explain capacity planning across power, cooling, space, network and weight, and describe how headroom is measured and reported

  • Distinguish availability tiers and redundancy topologies (N, N+1, 2N) and state what each protects against and what it does not

  • Draft an emergency response plan structure covering power loss, cooling failure, fire, flood, security breach and loss of key staff

  • Design a test and exercise schedule for continuity plans, including what evidence a test should produce

Your checkpoint

A capacity dashboard specification plus a one-page emergency response plan outline with test schedule

Week 8

Data Centre Operations Management (operational processes, service level and KPI management) & Facilities Management and Maintenance (planned and corrective maintenance, maintenance contracts) & Safety, Security and Environmental Management (physical security, health and safety, environmental controls) & Staffing, Training and Competence Management (organisation, roles, shift operations) & Governance, Compliance and Risk Management (standards, audits, documentation, risk) & Capacity, Availability and Continuity Management (capacity planning, resilience, emergency response)

  • Consolidate your notes into a single cross-domain summary that links each domain to the others through the operations processes

  • Complete timed practice questions across all six domains and record your accuracy per domain

  • Re-study only the two weakest domains using your own notes and correct any factual gaps you find

  • Rehearse explaining three scenario-based answers aloud in the time you would have in the exam

Your checkpoint

A scored practice log by domain with a short written plan for closing your two weakest areas

Milestones

Week 2: You can explain without notes how an SLA flows down to an OLA and a maintenance contract, and name the KPIs you would report monthly

Week 4: You can state the maintenance frequency and criticality for the main power, cooling and fire systems, and describe the controls at each physical security layer

Week 6: You can produce a scored risk register entry and describe your audit and documentation control approach end to end

Week 8: Practice accuracy is at least 70% overall with no domain below 60%, and you have a written remediation plan for the weakest two domains