CDFOM study plan
CDFOM · Give each week a clear focus.
8 weeks · About 7 hours per week
Data Centre Operations Management (operational processes, service level and KPI management)
Map the full set of operational processes a data centre runs on (incident, change, problem, capacity, asset, access) and write a one-line purpose and owner for each
Distinguish SLAs, SLRs, OLAs and underpinning contracts, and explain in your own notes how each is used to manage a service provider
Define at least 12 operational KPIs with formula, data source, target and escalation trigger for each
Draft a one-page monthly service review agenda that a facility manager would actually run with a client
Your checkpoint
A two-page operations reference sheet: process table, SLA/OLA comparison, and a 12-KPI register with formulas and thresholds
Data Centre Operations Management (operational processes, service level and KPI management) & Facilities Management and Maintenance (planned and corrective maintenance, maintenance contracts)
Build a 12-month planned maintenance calendar covering electrical, mechanical, fire, security and building fabric systems, noting typical frequencies for each
Explain the difference between planned, corrective, predictive and reactive maintenance and justify which work types can be deferred and which cannot
Draft the key clauses you would insist on in a maintenance contract: scope, response and fix times, spares, reporting, escalation, penalties, exit
Describe how a maintenance activity is risk-assessed and approved before it starts, including permit-to-work and change linkage
Your checkpoint
A maintenance calendar plus a one-page maintenance contract clause checklist with at least 10 must-have clauses
Facilities Management and Maintenance (planned and corrective maintenance, maintenance contracts)
Walk through the standard maintenance routines for UPS, generators, switchgear, chillers, CRAC/CRAH units and fire suppression, listing what is checked and why it matters
Explain how to manage a maintenance contractor on site: induction, supervision, sign-off, defect logging and closure
Design a defect and asset register structure that links every asset to its maintenance plan, criticality rating and spares holding
Set up a simple MTTR and PM compliance tracking method you could run in a spreadsheet
Your checkpoint
An asset criticality and maintenance matrix covering at least 15 asset types with frequency, owner and spares note
Safety, Security and Environmental Management (physical security, health and safety, environmental controls)
Layer a physical security model: perimeter, building, data hall, rack, and describe controls at each layer including access control, CCTV and visitor management
List the health and safety hazards specific to a live data centre and the control for each: arc flash, battery acid, refrigerant, noise, confined space, manual handling, working at height
Explain environmental monitoring parameters (temperature, humidity, particulate, differential pressure) and how alarms are escalated and acted on
Describe fire detection and suppression approaches and the operational rules that apply during and after a discharge
Your checkpoint
A security and safety control matrix mapping each layer or hazard to its control, monitoring method and responsible role
Staffing, Training and Competence Management (organisation, roles, shift operations)
Design a staffing model for a 24x7 facility: shift pattern, headcount maths including relief factor, and which roles must be on site versus on call
Write role profiles for facility technician, shift lead, security officer and facility manager with clear decision authority
Build a competence and authorisation framework: what training, assessment and re-certification each role needs before working unsupervised
Draft a shift handover procedure and an escalation matrix with named decision rights
Your checkpoint
A staffing and competence pack: headcount calculation, four role profiles and a shift handover template
Governance, Compliance and Risk Management (standards, audits, documentation, risk)
Map the standards and frameworks relevant to data centre operations and explain what each actually requires in practice
Design a documentation and records control scheme: which documents are controlled, retention periods, review cycle and access rules
Build a risk register with likelihood, impact, owner, mitigation and residual rating for at least 10 realistic operational risks
Plan an internal audit cycle with scope, sampling approach, findings grading and corrective action tracking
Your checkpoint
A risk register with 10 scored risks plus an audit and corrective action tracker template
Capacity, Availability and Continuity Management (capacity planning, resilience, emergency response) & Data Centre Operations Management (operational processes, service level and KPI management)
Explain capacity planning across power, cooling, space, network and weight, and describe how headroom is measured and reported
Distinguish availability tiers and redundancy topologies (N, N+1, 2N) and state what each protects against and what it does not
Draft an emergency response plan structure covering power loss, cooling failure, fire, flood, security breach and loss of key staff
Design a test and exercise schedule for continuity plans, including what evidence a test should produce
Your checkpoint
A capacity dashboard specification plus a one-page emergency response plan outline with test schedule
Data Centre Operations Management (operational processes, service level and KPI management) & Facilities Management and Maintenance (planned and corrective maintenance, maintenance contracts) & Safety, Security and Environmental Management (physical security, health and safety, environmental controls) & Staffing, Training and Competence Management (organisation, roles, shift operations) & Governance, Compliance and Risk Management (standards, audits, documentation, risk) & Capacity, Availability and Continuity Management (capacity planning, resilience, emergency response)
Consolidate your notes into a single cross-domain summary that links each domain to the others through the operations processes
Complete timed practice questions across all six domains and record your accuracy per domain
Re-study only the two weakest domains using your own notes and correct any factual gaps you find
Rehearse explaining three scenario-based answers aloud in the time you would have in the exam
Your checkpoint
A scored practice log by domain with a short written plan for closing your two weakest areas
Milestones
Week 2: You can explain without notes how an SLA flows down to an OLA and a maintenance contract, and name the KPIs you would report monthly
Week 4: You can state the maintenance frequency and criticality for the main power, cooling and fire systems, and describe the controls at each physical security layer
Week 6: You can produce a scored risk register entry and describe your audit and documentation control approach end to end
Week 8: Practice accuracy is at least 70% overall with no domain below 60%, and you have a written remediation plan for the weakest two domains