ID Electrician key terms
ID Electrician · Get comfortable with the vocabulary.
- NFPA 70 (National Electrical Code)
- Related: Article 100, Informational Note
The model electrical installation code published by NFPA and adopted by reference in Idaho; it sets minimum requirements for wiring, equipment, and installation methods enforced by inspection.
- Article 100
- Related: NFPA 70 (National Electrical Code)
The article of the Code that defines terms used throughout the document; those definitions control how requirements in every other article are interpreted and applied.
- Informational Note
- Related: NFPA 70 (National Electrical Code)
Explanatory text in the Code that offers guidance or points to related standards; it is not an enforceable requirement and carries no mandatory force of its own.
- Ampacity
- Related: Table 310.16, Conductor derating
The maximum continuous current, in amperes, that a conductor can carry under its conditions of use without exceeding its rated temperature.
- Table 310.16
- Related: Ampacity, Conductor derating
The Code table listing allowable ampacities for insulated conductors rated up to 2000 volts, assuming no more than three current-carrying conductors in a raceway or cable at a stated ambient temperature.
- Conductor derating
- Related: Ampacity, Table 310.16
Reducing a conductor's tabulated ampacity to account for conditions of use, such as more than three current-carrying conductors bundled in a raceway or a higher-than-assumed ambient temperature.
- Type NM-B cable
- Related: Type MC cable, Box fill calculation
A nonmetallic-sheathed cable with conductors rated 90 degrees C, widely used for dry interior residential wiring; it must be protected from physical damage and has use restrictions in Article 334.
- Type MC cable
- Related: Type NM-B cable, Electrical metallic tubing (EMT)
Metal-clad cable: factory-assembled conductors enclosed in a metallic armor, permitted in many locations where nonmetallic cable is not, with uses and limitations set by Article 330.
- Electrical metallic tubing (EMT)
- Related: Conduit fill, Securing and supporting
A thin-walled metal raceway joined with listed fittings and used indoors and in concrete, subject to the support, bending, and corrosion restrictions found in Article 358.
- Box fill calculation
- Related: Type NM-B cable
The method in Code section 314.16 that limits how many conductors, devices, and fittings may be installed in an outlet, junction, or device box, based on the box's marked volume.
- Conduit fill
- Related: Electrical metallic tubing (EMT)
The rule that conductors and cables may occupy only a set percentage of a raceway's internal cross-sectional area, determined from the tables in Chapter 9.
- Firestop
- Related: Securing and supporting
A listed material or assembly used to seal openings where cables or raceways pass through a fire-rated wall or floor so the assembly's fire resistance is maintained.
- Securing and supporting
- Related: Electrical metallic tubing (EMT), Type NM-B cable
Code rules stating how often and how close to boxes cables and raceways must be fastened and supported, with specifics found in each wiring-method article.
- Overcurrent protective device (OCPD)
- Related: Branch circuit, Feeder
A device such as a circuit breaker or fuse that automatically opens a circuit when current exceeds its rating, protecting conductors and equipment from overheating.
- Branch circuit
- Related: Feeder, Arc-fault circuit interrupter (AFCI)
The circuit conductors between the final overcurrent protective device protecting the circuit and the outlets, luminaires, or equipment that the circuit supplies.
- Multiwire branch circuit
- Related: Branch circuit, Grounded conductor
A branch circuit with two or more ungrounded conductors that have voltage between them and a shared grounded conductor, requiring a means to simultaneously disconnect all ungrounded conductors.
- Feeder
- Related: Overcurrent protective device (OCPD), Branch circuit
All circuit conductors between the service equipment, source of a separately derived system, or other supply source and the final branch-circuit overcurrent protective device.
- Continuous load
- Related: Feeder, Overcurrent protective device (OCPD)
A load expected to operate at maximum current for three hours or more; branch circuits, feeders, and overcurrent devices serving it are generally sized at 125 percent of the load.
- Ground-fault circuit interrupter (GFCI)
- Related: Arc-fault circuit interrupter (AFCI), Grounded conductor
A device that trips when it senses a small current imbalance between ungrounded and grounded conductors, indicating leakage to ground; required in many wet, outdoor, and dwelling-unit locations.
- Arc-fault circuit interrupter (AFCI)
- Related: Ground-fault circuit interrupter (GFCI), Branch circuit
A device that recognizes the signature of dangerous arcing in branch-circuit wiring and opens the circuit; required for many dwelling-unit branch circuits under Article 210.
- Grounded conductor
- Related: Main bonding jumper, Equipment grounding conductor (EGC)
The circuit conductor intentionally connected to ground at the source, commonly the neutral; it carries current during normal operation and is identified by white or gray.
- Equipment grounding conductor (EGC)
- Related: Grounding electrode, Main bonding jumper
The conductive path that connects normally non-current-carrying metal parts to the system grounding point so fault current can return and open the overcurrent device.
- Grounding electrode
- Related: Main bonding jumper, Equipment grounding conductor (EGC)
A conductive object such as a rod, pipe, plate, or concrete-encased electrode in direct contact with the earth, to which the grounding electrode conductor is connected.
- Main bonding jumper
- Related: Grounded conductor, Equipment grounding conductor (EGC)
The conductor, screw, or strap that connects the equipment grounding conductor bus to the grounded conductor bus at the service equipment or at the source of a separately derived system.
- Working clearance
- Related: Arc flash, Lockout/tagout
The clear, unobstructed space required in front of electrical equipment, with depth based on voltage and site conditions, so workers can safely operate and service it.
- Arc flash
- Related: Lockout/tagout, Working clearance
A short circuit through air that releases intense heat, light, and pressure; the hazard is controlled by de-energizing, lockout/tagout, and required personal protective equipment.
- Lockout/tagout
- Related: Working clearance, Arc flash
A procedure for de-energizing equipment and applying locks and tags so the equipment cannot be re-energized while someone is working on or near it.
- Motor full-load current (FLC)
- Related: Motor overload protection, Motor branch-circuit short-circuit and ground-fault protection
The current a motor draws at rated load, taken from the Code motor tables rather than the nameplate for sizing conductors, overload protection, and short-circuit protection.
- Motor overload protection
- Related: Motor full-load current (FLC), Motor disconnecting means
A device that protects the motor against sustained excess current from an overload, selected using the motor's nameplate current, service factor, and temperature rise.
- Motor branch-circuit short-circuit and ground-fault protection
- Related: Motor full-load current (FLC), Overcurrent protective device (OCPD)
The branch-circuit breaker or fuses that clear short circuits and grounds on a motor circuit, sized from the table current and permitted to be larger than the overload device rating.
- Motor disconnecting means
- Related: Motor overload protection, Lockout/tagout
A switch or circuit breaker, in sight of the motor or capable of being locked open, that isolates the motor and controller from all supply conductors for servicing.
- Hazardous (classified) location
- Related: Class I, Division 1 location
An area where fire or explosion hazards may exist because of flammable gases, vapors, dusts, or fibers, classified by class, division or zone, and group in Articles 500 through 516.
- Class I, Division 1 location
- Related: Hazardous (classified) location
A location where ignitable concentrations of flammable gases or vapors exist under normal operating conditions or occur frequently; equipment there must be listed and marked for the classification.
- Idaho Electrical Board
- Related: Idaho Division of Occupational and Professional Licenses (IDOPL), Journeyman electrician license
The board within Idaho's occupational licensing structure that oversees electrician and electrical contractor licensing, recommends and adopts rules, and takes part in disciplinary actions.
- Idaho Division of Occupational and Professional Licenses (IDOPL)
- Related: Idaho Electrical Board, Electrical contractor license
The state agency that administers Idaho electrician and electrical contractor licensing, including applications, examinations, license renewal, and enforcement of board rules.
- Journeyman electrician license
- Related: Apprentice electrician registration, Master electrician license
An Idaho license issued after documented experience and a passed examination that allows the holder to perform electrical work for a licensed contractor and to work without constant supervision.
- Master electrician license
- Related: Journeyman electrician license, Electrical contractor license
The highest electrician license Idaho issues, requiring more documented experience than the journeyman level plus a passed examination and allowing the holder to supervise electrical work.
- Apprentice electrician registration
- Related: Journeyman electrician license
An Idaho registration for a person learning the trade while working under required supervision, enrolled in related training, and progressing toward journeyman status.
- Electrical contractor license
- Related: Master electrician license, Journeyman electrician license
An Idaho license held by a business that performs electrical work for others; the business must meet board licensing requirements, including having a qualifying licensed electrician.
- Continuing education
- Related: Journeyman electrician license, Master electrician license
Credit hours a licensee must complete during each renewal cycle to keep an Idaho electrician license active, covering code updates and related technical or safety topics set by board rule.