ID Electrician · Get comfortable with the vocabulary.

NFPA 70 (National Electrical Code)

The model electrical installation code published by NFPA and adopted by reference in Idaho; it sets minimum requirements for wiring, equipment, and installation methods enforced by inspection.

Related: Article 100, Informational Note
Article 100

The article of the Code that defines terms used throughout the document; those definitions control how requirements in every other article are interpreted and applied.

Related: NFPA 70 (National Electrical Code)
Informational Note

Explanatory text in the Code that offers guidance or points to related standards; it is not an enforceable requirement and carries no mandatory force of its own.

Related: NFPA 70 (National Electrical Code)
Ampacity

The maximum continuous current, in amperes, that a conductor can carry under its conditions of use without exceeding its rated temperature.

Related: Table 310.16, Conductor derating
Table 310.16

The Code table listing allowable ampacities for insulated conductors rated up to 2000 volts, assuming no more than three current-carrying conductors in a raceway or cable at a stated ambient temperature.

Related: Ampacity, Conductor derating
Conductor derating

Reducing a conductor's tabulated ampacity to account for conditions of use, such as more than three current-carrying conductors bundled in a raceway or a higher-than-assumed ambient temperature.

Related: Ampacity, Table 310.16
Type NM-B cable

A nonmetallic-sheathed cable with conductors rated 90 degrees C, widely used for dry interior residential wiring; it must be protected from physical damage and has use restrictions in Article 334.

Related: Type MC cable, Box fill calculation
Type MC cable

Metal-clad cable: factory-assembled conductors enclosed in a metallic armor, permitted in many locations where nonmetallic cable is not, with uses and limitations set by Article 330.

Related: Type NM-B cable, Electrical metallic tubing (EMT)
Electrical metallic tubing (EMT)

A thin-walled metal raceway joined with listed fittings and used indoors and in concrete, subject to the support, bending, and corrosion restrictions found in Article 358.

Related: Conduit fill, Securing and supporting
Box fill calculation

The method in Code section 314.16 that limits how many conductors, devices, and fittings may be installed in an outlet, junction, or device box, based on the box's marked volume.

Related: Type NM-B cable
Conduit fill

The rule that conductors and cables may occupy only a set percentage of a raceway's internal cross-sectional area, determined from the tables in Chapter 9.

Related: Electrical metallic tubing (EMT)
Firestop

A listed material or assembly used to seal openings where cables or raceways pass through a fire-rated wall or floor so the assembly's fire resistance is maintained.

Related: Securing and supporting
Securing and supporting

Code rules stating how often and how close to boxes cables and raceways must be fastened and supported, with specifics found in each wiring-method article.

Related: Electrical metallic tubing (EMT), Type NM-B cable
Overcurrent protective device (OCPD)

A device such as a circuit breaker or fuse that automatically opens a circuit when current exceeds its rating, protecting conductors and equipment from overheating.

Related: Branch circuit, Feeder
Branch circuit

The circuit conductors between the final overcurrent protective device protecting the circuit and the outlets, luminaires, or equipment that the circuit supplies.

Related: Feeder, Arc-fault circuit interrupter (AFCI)
Multiwire branch circuit

A branch circuit with two or more ungrounded conductors that have voltage between them and a shared grounded conductor, requiring a means to simultaneously disconnect all ungrounded conductors.

Related: Branch circuit, Grounded conductor
Feeder

All circuit conductors between the service equipment, source of a separately derived system, or other supply source and the final branch-circuit overcurrent protective device.

Related: Overcurrent protective device (OCPD), Branch circuit
Continuous load

A load expected to operate at maximum current for three hours or more; branch circuits, feeders, and overcurrent devices serving it are generally sized at 125 percent of the load.

Related: Feeder, Overcurrent protective device (OCPD)
Ground-fault circuit interrupter (GFCI)

A device that trips when it senses a small current imbalance between ungrounded and grounded conductors, indicating leakage to ground; required in many wet, outdoor, and dwelling-unit locations.

Related: Arc-fault circuit interrupter (AFCI), Grounded conductor
Arc-fault circuit interrupter (AFCI)

A device that recognizes the signature of dangerous arcing in branch-circuit wiring and opens the circuit; required for many dwelling-unit branch circuits under Article 210.

Related: Ground-fault circuit interrupter (GFCI), Branch circuit
Grounded conductor

The circuit conductor intentionally connected to ground at the source, commonly the neutral; it carries current during normal operation and is identified by white or gray.

Related: Main bonding jumper, Equipment grounding conductor (EGC)
Equipment grounding conductor (EGC)

The conductive path that connects normally non-current-carrying metal parts to the system grounding point so fault current can return and open the overcurrent device.

Related: Grounding electrode, Main bonding jumper
Grounding electrode

A conductive object such as a rod, pipe, plate, or concrete-encased electrode in direct contact with the earth, to which the grounding electrode conductor is connected.

Related: Main bonding jumper, Equipment grounding conductor (EGC)
Main bonding jumper

The conductor, screw, or strap that connects the equipment grounding conductor bus to the grounded conductor bus at the service equipment or at the source of a separately derived system.

Related: Grounded conductor, Equipment grounding conductor (EGC)
Working clearance

The clear, unobstructed space required in front of electrical equipment, with depth based on voltage and site conditions, so workers can safely operate and service it.

Related: Arc flash, Lockout/tagout
Arc flash

A short circuit through air that releases intense heat, light, and pressure; the hazard is controlled by de-energizing, lockout/tagout, and required personal protective equipment.

Related: Lockout/tagout, Working clearance
Lockout/tagout

A procedure for de-energizing equipment and applying locks and tags so the equipment cannot be re-energized while someone is working on or near it.

Related: Working clearance, Arc flash
Motor full-load current (FLC)

The current a motor draws at rated load, taken from the Code motor tables rather than the nameplate for sizing conductors, overload protection, and short-circuit protection.

Related: Motor overload protection, Motor branch-circuit short-circuit and ground-fault protection
Motor overload protection

A device that protects the motor against sustained excess current from an overload, selected using the motor's nameplate current, service factor, and temperature rise.

Related: Motor full-load current (FLC), Motor disconnecting means
Motor branch-circuit short-circuit and ground-fault protection

The branch-circuit breaker or fuses that clear short circuits and grounds on a motor circuit, sized from the table current and permitted to be larger than the overload device rating.

Related: Motor full-load current (FLC), Overcurrent protective device (OCPD)
Motor disconnecting means

A switch or circuit breaker, in sight of the motor or capable of being locked open, that isolates the motor and controller from all supply conductors for servicing.

Related: Motor overload protection, Lockout/tagout
Hazardous (classified) location

An area where fire or explosion hazards may exist because of flammable gases, vapors, dusts, or fibers, classified by class, division or zone, and group in Articles 500 through 516.

Related: Class I, Division 1 location
Class I, Division 1 location

A location where ignitable concentrations of flammable gases or vapors exist under normal operating conditions or occur frequently; equipment there must be listed and marked for the classification.

Related: Hazardous (classified) location
Idaho Electrical Board

The board within Idaho's occupational licensing structure that oversees electrician and electrical contractor licensing, recommends and adopts rules, and takes part in disciplinary actions.

Related: Idaho Division of Occupational and Professional Licenses (IDOPL), Journeyman electrician license
Idaho Division of Occupational and Professional Licenses (IDOPL)

The state agency that administers Idaho electrician and electrical contractor licensing, including applications, examinations, license renewal, and enforcement of board rules.

Related: Idaho Electrical Board, Electrical contractor license
Journeyman electrician license

An Idaho license issued after documented experience and a passed examination that allows the holder to perform electrical work for a licensed contractor and to work without constant supervision.

Related: Apprentice electrician registration, Master electrician license
Master electrician license

The highest electrician license Idaho issues, requiring more documented experience than the journeyman level plus a passed examination and allowing the holder to supervise electrical work.

Related: Journeyman electrician license, Electrical contractor license
Apprentice electrician registration

An Idaho registration for a person learning the trade while working under required supervision, enrolled in related training, and progressing toward journeyman status.

Related: Journeyman electrician license
Electrical contractor license

An Idaho license held by a business that performs electrical work for others; the business must meet board licensing requirements, including having a qualifying licensed electrician.

Related: Master electrician license, Journeyman electrician license
Continuing education

Credit hours a licensee must complete during each renewal cycle to keep an Idaho electrician license active, covering code updates and related technical or safety topics set by board rule.

Related: Journeyman electrician license, Master electrician license